Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-33046500

RESUMO

Current guidelines recommend vancomycin and linezolid as first-line agents against methicillin-resistant Staphylococcus aureus (MRSA) nosocomial pneumonia. Telavancin is a potential new therapeutic alternative, specifically in monomicrobial MRSA pneumonia. This study compared the efficacies of telavancin versus linezolid in a porcine model of severe MRSA pneumonia. In 18 mechanically ventilated pigs (32.11 ± 1.18 kg), 75 ml of 106 CFU/ml of MRSA was administered into each pulmonary lobe. After the onset of pneumonia, pigs were randomized into three groups: a control group, a group receiving 22.5 mg/kg of body weight every 24 h (q24h) of telavancin, and a group receiving 10 mg/kg q12h of linezolid intravenously. Tracheal aspirate and bronchoalveolar lavage (BAL) fluids were cultured every 24 h. After 48 h of treatment, tissue samples were collected from the ventral and dorsal sections of each lobe. Microbiological and histopathological analyses were performed. Lung tissue concentrations differed among the groups (P = 0.019), with the lowest MRSA lung burden in the telavancin group (P < 0.05 versus the control). MRSA was detected in 46.7%, 40.0%, and 21.7% of the lung tissue samples from the control, linezolid, and telavancin groups, respectively (P < 0.001). MRSA concentrations differed among the groups in tracheal aspirate fluid (P = 0.011) but not in BAL fluid. Furthermore, there was no increased risk of kidney injury during telavancin use. Thus, telavancin has higher bactericidal efficacy than linezolid during the first 48 h of treatment in a porcine model of severe MRSA pneumonia. However, studies are needed to confirm the benefits of telavancin in treating MRSA nosocomial pneumonia.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Pneumonia Estafilocócica , Aminoglicosídeos , Animais , Antibacterianos/uso terapêutico , Linezolida/uso terapêutico , Lipoglicopeptídeos , Pneumonia Estafilocócica/tratamento farmacológico , Suínos
2.
Br J Anaesth ; 122(2): 269-276, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30686313

RESUMO

BACKGROUND: Recruitment manoeuvres generate a transient increase in trans-pulmonary pressure that could open collapsed alveoli. Recruitment manoeuvres might generate very high inspiratory airflows. We evaluated whether recruitment manoeuvres could displace respiratory secretions towards the distal airways and impair gas exchange in a porcine model of bacterial pneumonia. METHODS: We conducted a prospective randomised study in 10 mechanically ventilated pigs. Pneumonia was produced by direct intra-bronchial introduction of Pseudomonas aeruginosa. Four recruitment manoeuvres were applied randomly: extended sigh (ES), maximal recruitment strategy (MRS), sudden increase in driving pressure and PEEP (SI-PEEP), and sustained inflation (SI). Mucus transport was assessed by fluoroscopic tracking of radiopaque disks before and during each recruitment manoeuvre. The effects of each RM on gas exchange were assessed 15 min after the intervention. RESULTS: Before recruitment manoeuvres, mucus always cleared towards the glottis. Conversely, mucus was displaced towards the distal airways in 28.6% ES applications and 50% of all other recruitment manoeuvres (P=0.053). Median mucus velocity was 1.26 mm min-1 [0.48-3.89] before each recruitment manoeuvre, but was reversed (P=0.007) during ES [0.10 mm min-1 [-0.04-1.00]], MRS [0.10 mm min-1 [-0.4-0.48]], SI-PEEP [0.02 mm min-1 [-0.14-0.34]], and SI [0.10 mm min-1 [-0.63-0.75]]. When PaO2 failed to improve after recruitment manoeuvre, mucus was displaced towards the distal airways in 68.7% of the cases, compared with 31.2% recruitment manoeuvres associated with improved PaO2 (odds ratio: 4.76 (95% confidence interval: 1.13-19.97). CONCLUSIONS: Recruitment manoeuvres dislodge mucus distally, irrespective of airflow generated by different recruitment manoeuvres. Further investigation in humans is warranted to corroborate these pre clinical findings, as there may be limited benefits associated with lung recruitment in pneumonia.


Assuntos
Manuseio das Vias Aéreas/métodos , Intubação Intratraqueal/métodos , Muco , Pneumonia Bacteriana/complicações , Animais , Modelos Animais de Doenças , Feminino , Pico do Fluxo Expiratório , Estudos Prospectivos , Pseudomonas aeruginosa , Troca Gasosa Pulmonar , Respiração Artificial , Mecânica Respiratória , Sus scrofa , Suínos
3.
Anaesthesia ; 73(11): 1372-1381, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30298583

RESUMO

Leakage of colonised oropharyngeal secretions across the tracheal tube cuff may cause iatrogenic pulmonary infection. We studied a novel 'add-on' cuff, which can be inserted over an existing tracheal tube and advanced into the subglottic region. The physical properties of the novel silicone cuff (BronchoGuard, Ciel Medical, USA) were evaluated in comparison with the Hi-Lo® tracheal tube. In a bench study, we identified saline inflation volumes required to transmit pressures between 15 and 30 cmH2 O against artificial tracheas of 18, 20 and 22 mm internal diameter. We computed cuff compliance, and minimal inflation volume to achieve air sealing during mechanical ventilation. Finally, we compared the leakage flow rate of artificial saliva across the novel cuff. On average, the mean (SD) inflation volumes necessary to transmit tracheal pressures of 15, 20, 25 and 30 cmH2 O were 4.1 (2.2), 4.4 (2.3), 4.6 (2.4) and 4.8 (2.4) ml for the novel cuff and 7.7 (2.5), 8.0 (2.6), 8.4 (2.6) and 8.7 (2.7) ml for the Hi-Lo tube, respectively (p < 0.001). The minimal inflation volumes to achieve air sealing were 3.8 (0.9) and 10.5 (2.1) ml (p < 0.001), which resulted in transmitted tracheal pressures of 8.3 (9.8) and 27.6 (34.8) cmH2 O (p < 0.001). Compliance was 0.026 (0.004) and 0.616 (0.324) ml.cmH2 0-1 , respectively (p < 0.001). Although massive leak was found when the novel cuff transmitted pressures ≤ 20 cmH2 O against the trachea, leakage was avoided with pressures ≥ 25 cmH2 O, owing to optimal contact between the cuff and the tracheal wall. In contrast, the standard cuff consistently leaked irrespective of the pressure. We conclude that the novel cuff has advantageous properties that warrant clinical corroboration.


Assuntos
Intubação Intratraqueal/instrumentação , Desenho de Equipamento , Técnicas In Vitro , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...