1.
Sci Rep ; 12(1): 4726, 2022 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-35304544

RESUMO

Multi-frequency processing (MFP) leads to enhanced image quality (IQ) of radiographs. This study is to determine the effect of third generation MFP (M3) on IQ in comparison to standard second-generation MFP (M2). 20 cadavers were examined and post-processing of radiographs was performed with both M2 and M3. Three readers blinded to the MFP used for each image independently compared corresponding image pairs according to overall IQ and depiction of bony structures and soft tissue (+ 2: notably better > 0: equal > - 2: notably worse). A significant deviation of the median grade from grade 0 (equal) (p < 0.01) for each evaluator A, B and C speaks against an equal image quality of M2- and M3-images. M3-images were categorized with better grades (+ 1, + 2) in 87.7% for overall image quality, in 90.4% for soft tissue and 81.8% for bony structures. M3 images showed significant higher averaged SNR and CNR for all investigated lower extremities than that of M2 images (0.031 < p < 0.049). The newest generation of MFP leads to significantly better depiction of anatomical structures and overall image quality than in images processed with the preceding generation of MFP. This provides increased diagnostic accuracy and further decreased radiation exposure.


Assuntos
Osso e Ossos , Processamento de Imagem Assistida por Computador , Osso e Ossos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Radiografia
2.
Sci Rep ; 11(1): 7701, 2021 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-33833315

RESUMO

In recent phantom studies low-contrast detectability was shown to be independent from variations in tube voltage in digital radiography (DR) systems. To investigate the transferability to a clinical setting, the lower extremities of human cadavers were exposed at constant detector doses with different tube voltages in a certain range, as proposed in the phantom studies. Three radiologists independently graded different aspects of image quality (IQ) in a comparative analysis. The grades show no correlation between IQ and kV, which means that the readers were not able to recognize a significant IQ difference at different kV. Signal-to-noise and contrast-to-noise ratios showed no significant differences in IQ despite the kV-setting variations. These findings were observed from a limited kV range setting. Higher kV-settings resulted in lowest patient exposure at constant IQ. These results confirm the potential of DR-systems to contribute to standardization of examination protocols comparable to computed tomography. This may prevent the trend to overexpose. Further investigations in other body regions and other DR-systems are encouraged to determine transferability.

3.
Eur Radiol ; 27(8): 3443-3451, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27988890

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. METHODS: Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. RESULTS: Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. CONCLUSION: MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. KEY POINTS: • MDCT is an accurate alternative to MRI in disc herniation diagnosis. • By IR enhanced image quality improves MDCT diagnostic confidence similar to MRI. • Advances in CT technology contribute to improved diagnostic performance in lumbar spine imaging.


Assuntos
Deslocamento do Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Deslocamento do Disco Intervertebral/complicações , Dor Lombar/diagnóstico por imagem , Dor Lombar/etiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Radiculopatia/diagnóstico por imagem , Radiculopatia/etiologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Radiologe ; 56(3): 233-9, 2016 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-26842999

RESUMO

BACKGROUND: Despite enormous technical progress the results of endovascular treatment of the femoropopliteal vasculature are unsatisfactory and its role is still controversially discussed. In the past decade numerous new stent designs have come onto the market but it is unclear whether they have benefits with respect to patency rates. OBJECTIVES: Comparison of published data on patency rates and target lesion revascularization rates after use of different stent designs in the femoropopliteal vasculature. MATERIAL AND METHODS: Analysis of 25 published studies and registries from 2006 to 2015 for classical open-cell stents, interwoven stents and partially or fully covered stents. RESULTS AND CONCLUSION: The published data are heterogeneous and comparative studies for different stent designs are completely missing. Over the past decade the patency rates after femoropopliteal stenting could be improved. According to available data stenting of short lesions < 5 cm does not show any benefit compared to isolated balloon angioplasty. Primary stenting is now recommended for intermediate and longer lesions > 6.4 cm. Due to the heterogeneity of published data a clear benefit for a specific stent design is not obvious; however, data for interwoven stents are promising and show a tendency towards improved patency, at least for certain lesions. Randomized controlled comparative trials are needed to confirm this result.


Assuntos
Arteriopatias Oclusivas/epidemiologia , Arteriopatias Oclusivas/cirurgia , Procedimentos Endovasculares/estatística & dados numéricos , Artéria Femoral/cirurgia , Artéria Poplítea/cirurgia , Stents/estatística & dados numéricos , Arteriopatias Oclusivas/diagnóstico , Análise de Falha de Equipamento , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/epidemiologia , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto , Humanos , Prevalência , Desenho de Prótese , Reoperação/estatística & dados numéricos , Fatores de Risco , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
Eur Radiol ; 26(6): 1818-25, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26334511

RESUMO

OBJECTIVES: To compare a modified T1-weighted 3D TSE black-blood sequence with sub-millimetre resolution (T1-mVISTA) with a magnetization-prepared rapid gradient echo (MP-RAGE) sequence for the diagnosis of cerebral malignomas. METHODS: Forty-six patients with known or suspected intracranial tumours and 15 control patients were included in this retrospective study. All patients underwent T1-mVISTA (0.75-mm isotropic resolution, 4:43 min) and MP-RAGE (0.8-mm isotropic resolution, 4:46 minutes) at 3-Tesla in random order after application of contrast agent. Two experienced radiologists determined the number of lesions. Maximum diameter, diagnostic confidence (DC), visual assessment of contrast enhancement (VCE) and CNRlesion/parenchyma were assessed for each lesion. RESULTS: Significantly more lesions were detected with T1-mVISTA compared to the MP-RAGE (61 vs. 36; p < 0.05). Further, DC and VCE was rated significantly higher in the T1-mVISTA (p < 0.05 and p < 0.001). Mean CNRlesion/parenchyma was twofold higher for T1-mVISTA (24.2 ± 17.5 vs. 12.7 ± 11.5, p < 0.001). The 25 lesions detected only in T1-mVISTA were significantly smaller than those detected in both sequences (4.3 ± 3.7 mm vs. 11.3 ± 10.7 mm; p < 0.01). CONCLUSIONS: T1-mVISTA increases the contrast of lesions significantly compared to MP-RAGE and might therefore improve detection rates of small lesions in early stages of disease. KEY POINTS: • T1-mVISTA leads to significantly higher contrast-to-noise ratios of cerebral malignomas. • T1-mVISTA detects significantly more metastatic lesions compared to 3D-MPRAGE. • Lesions detected only by T1-mVISTA are smaller than those detected in both sequences. • Diagnostic confidence is significantly higher for lesions detected by T1-mVISTA. • Application of T1-mVISTA might be of high relevance in early stages of disease.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Adolescente , Adulto , Idoso , Neoplasias Encefálicas/patologia , Criança , Pré-Escolar , Meios de Contraste , Feminino , Compostos Heterocíclicos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Retrospectivos , Adulto Jovem