Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Radiol Oncol ; 58(1): 33-42, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38378033

RESUMO

BACKGROUND: The aim of the study was to assess the role of diffusion-weighted imaging (DWI) to evaluate treatment response in patients with liver metastases of colorectal cancer. PATIENTS AND METHODS: In this retrospective, observational cohort study, we included 19 patients with 18 responding metastases (R-Mets; follow-up at least one year) and 11 non-responding metastases (NR-Mets; local tumor recurrence within one year) who were treated with high-dose-rate brachytherapy (HDR-BT) and underwent pre- and post-interventional MRI. DWI (qualitatively, mean apparent diffusion coefficient [ADCmean], ADCmin, intraindividual change of ADCmean and ADCmin) were evaluated and compared between pre-interventional MRI, first follow-up after 3 months and second follow-up at the time of the local tumor recurrence (in NR-Mets, mean: 284 ± 122 d) or after 12 months (in R-Mets, mean: 387+/-64 d). Sensitivity, specificity, positive predictive values (PPVs), and negative predictive values (NPVs) for detection of local tumor recurrence were calculated on second follow up, evaluating (1) DWI images only, and (2) DWI with Gd-enhanced T1-weighted images on hepatobiliary phase (contrast-enhanced [CE] T1-weight [T1w] hepatobiliary phase [hb]). RESULTS: ADCmean significantly increased 3 months after HDR-BT in both groups (R-Mets: 1.48 ± 0.44 and NR-Mets: 1.49 ± 0.19 x 10-3 mm2;/s, p < 0.0001 and p = 0.01), however, intraindividual change of ADCmean (175% vs.127%, p = 0.03) and ADCmin values (0.44 ± 0.24 to 0.82 ± 0.58 x 10-3 mm2/s) significantly increased only in R-Mets (p < 0.0001 and p < 0.001). ADCmin was significant higher in R-Mets compared to NR-Mets on first follow-up (p = 0.04). Sensitivity (1 vs. 0.72), specificity (0.94 vs. 0.72), PPV (0.91 vs. 0.61) and NPV (1 vs. 0.81) could be improved by combining DWI with CE T1w hb compared to DWI only. CONCLUSIONS: DW-MRI seems to be helpful in the qualitative and quantitative evaluation of treatment response after HDR-BT of colorectal metastases in the liver.


Assuntos
Braquiterapia , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Estudos Retrospectivos , Braquiterapia/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/patologia
2.
Acta Radiol ; 63(7): 877-888, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34225464

RESUMO

BACKGROUND: In patients with hepatic neuroendocrine tumors (NETs) locoregional therapies such as transarterial radioembolization (TARE) are increasingly applied. Response evaluation remains challenging and previous studies assessing response with diffusion-weighted imaging (DWI) have been inconclusive. PURPOSE: To perform a feasibility study to evaluate if response assessment with quantitative apparent diffusion coefficient (ADC) in patients with liver metastases of NETs after TARE will be possible. MATERIAL AND METHODS: Retrospectively, 43 patients with 120 target lesions who obtained abdominal magnetic resonance imaging (MRI) with DWI 39±28 days before and 74±46 days after TARE were included. Intralesional ADC (ADCmin, ADCmax, and ADCmean) were measured for a maximum number of three lesions per patient on baseline and post-interventional DWI. Tumor response was categorized according to RECIST 1.1 and mRECIST. RESULTS: TARE resulted in partial remission (PR) in 23% (63%), in stable disease (SD) in 73% (23%), in progressive disease (PD) in 5% (7%) and in complete response (CR) in 0% (1%) according to RECIST 1.1 (mRECIST, respectively). ADC values increased significantly (P<0.005) after TARE in the PR group whereas there was no significant change in the PD group. Post-therapeutic ADC values of SD lesions increased significantly when evaluated by RECIST 1.1 but not if evaluated by mRECIST. Percentual changes of ADCmean values were slightly higher for responders compared to non-responders (P<0.05). CONCLUSION: ADC values seem to represent an additional marker for treatment response evaluation after TARE in patients with secondary hepatic NET. A conclusive study seems feasible though patient-based evaluation and overall survival and progression free survival as alternate primary endpoints should be considered.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Tumores Neuroendócrinos , Imagem de Difusão por Ressonância Magnética/métodos , Embolização Terapêutica/métodos , Estudos de Viabilidade , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
3.
Skeletal Radiol ; 51(1): 43-58, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34031705

RESUMO

Myeloma-associated bone disease (MBD) develops in about 80-90% of patients and severely affects their quality of life, as it accounts for the majority of mortality and morbidity. Imaging in multiple myeloma (MM) and MBD is of utmost importance in order to detect bone and bone marrow lesions as well as extraosseous soft-tissue masses and complications before the initiation of treatment. It is required for determination of the stage of disease and aids in the assessment of treatment response. Whole-body low-dose computed tomography (WBLDCT) is the key modality to establish the initial diagnosis of MM and is now recommended as reference standard procedure for the detection of lytic destruction in MBD. In contrast, whole-body magnetic resonance imaging (WBMRI) has higher sensitivity for the detection of focal and diffuse plasma cell infiltration patterns of the bone marrow and identifies them prior to osteolytic destruction. It is recommended for the evaluation of spinal and vertebral lesions, while functional, diffusion-weighted MRI (DWI-MRI) is a promising tool for the assessment of treatment response. This review addresses the current improvements and limitations of WBCT and WBMRI for diagnosis and staging in MM, underlining the fact that both modalities offer complementary information. It further summarizes the corresponding radiological findings and novel technological aspects of both modalities.


Assuntos
Mieloma Múltiplo , Humanos , Imageamento por Ressonância Magnética , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Estadiamento de Neoplasias , Qualidade de Vida , Tomografia Computadorizada por Raios X , Imagem Corporal Total
5.
Cardiovasc Intervent Radiol ; 44(5): 700-708, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33280059

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of a filter embolic protection device (FEPD) in endovascular interventions of the femoropopliteal arteries. METHODS: Patients who underwent endovascular interventions of the femoropopliteal arteries between 2008 and 2016 and in whom the SpiderFXTM FEPD was applied were included in this retrospective study. Clinical and angiographic characteristics, filter macroembolization (FME), device-related complications, distal embolization, as well as the early clinical and hemodynamic outcome, were assessed. Potential risk factors for FME were evaluated by multivariate analysis. RESULTS: A total of 244 cases were identified (203 patients, claudication 60.4%, critical limb ischaemia 39.6%, mean lesion length 13.2 ± 12.9 cm, complete occlusions in 72.7%). Balloon angioplasty ± stenting (BAP), directional atherectomy ± balloon angioplasty ± stenting (DA) and rotational thrombectomy ± balloon angioplasty ± stenting (RT) were performed in 141, 61 and 42 cases, respectively. FEPD placement and retrieval were successful in all but one case each. Permanent filter-related vessel damage was not observed. The rate of FME was 37.3% (BAP 36.2%, DA 32.8%, RT 47.7%). Risk factors for FME in the BAP- and DA-group were total occlusion, lesion length > 19 cm, visible thrombus and diabetes mellitus. The distal embolization rate despite filter protection was 4.1 % (BAP 4.9%, DA 1.6%, RT 4.8%) and was higher in cases with FME compared with those without FME (8.7% vs. 1.5%, p = 0.02). CONCLUSION: The Spider FXTM device is safe and effective in capturing embolic debris during femoropopliteal interventions. A residual risk of peripheral embolization remains. LEVEL OF EVIDENCE: III, Cohort study.


Assuntos
Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/cirurgia , Claudicação Intermitente/cirurgia , Artéria Poplítea/cirurgia , Idoso , Estudos de Coortes , Embolia/etiologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Sci Rep ; 10(1): 9405, 2020 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-32523085

RESUMO

This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60 kV for all media in ATI and DFI, at 80 kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined.


Assuntos
Meios de Contraste/química , Radiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Microbolhas , Doses de Radiação , Raios X
7.
Eur Radiol ; 30(8): 4564-4572, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32232789

RESUMO

OBJECTIVES: To assess the diagnostic accuracy (ACC) of post-mortem computed tomography (PMCT) for fractures of the isolated larynx-hyoid complex (LHC) in comparison to post-mortem fine preparation (PMFP). METHODS: This monocentric prospective study enclosed 54 LHCs that were extracted during autopsy, fixed in formalin, and underwent a PMCT scan (64-row multidetector CT, helical pitch). Two radiologists independently analyzed the LHC scans for image quality (IQ) and fractures (4-point Likert scales). A specialized forensic preparator dissected the specimens under the stereomicroscope. The PMFP results were standardized documented, and used as the standard of reference for the comparison to PMCT. RESULTS: The PMCT-IQ of 95% of the LHC images was rated as good or excellent. IQ was decreased by decay, incisions during autopsy, and separation of the hyoid from the cartilaginous components in 7, 3, and 12 specimens, respectively. PMFP detected 119 fractures in 34 LHCs (63.0%). PMCT identified 91 fractures in 32 specimens (59.3%). PMFP and PMCT significantly agreed concerning the location (Cohen's κ = 0.762; p < 0.001) and the degree of dislocation (κ = 0.689; p < 0.001) of the fractures. Comparing PMCT to PMFP resulted in a sensitivity of 88.2%, a specificity of 90.0%, and an ACC of 88.9% for the LHC. The ACCs for the hyoid, thyroid, and cricoid were 94.4%, 87.0%, and 81.5%, respectively. PMCT procedure was significantly faster than PMFP (28.9 ± 4.1 min vs. 208.2 ± 32.5 min; p < 0,001). CONCLUSIONS: PMCT can detect distinct injuries of the isolated LHC and may promptly confirm violence against the neck as cause of death. PMFP outmatches PMCT in the detection of decent injuries like tears of the cricoid cartilage. KEY POINTS: • Post-mortem computed tomography is able to assess fractures of the larynx-hyoid complex. • Prospective monocentric in vitro study showed that post-mortem computed tomography of the larynx-hyoid complex is faster than post-mortem fine preparation. • Post-mortem computed tomography can confirm violence against the neck as cause of death.


Assuntos
Medicina Legal/métodos , Fraturas Ósseas/diagnóstico por imagem , Osso Hioide/diagnóstico por imagem , Osso Hioide/lesões , Laringe/diagnóstico por imagem , Laringe/lesões , Tomografia Computadorizada Multidetectores/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Causas de Morte , Estudos de Coortes , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
8.
Eur Radiol ; 30(2): 1041-1044, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31529250

RESUMO

OBJECTIVES: To assess the value of a T1-3D black-blood turbo spin echo (TSE) sequence for the diagnosis of abdominal large vessel vasculitis (LVV). MATERIALS AND METHODS: The study included 20 patients with abdominal LVV and 17 controls, who underwent a 3T-MRI scan using a modified T1-3D volumetric isotropic TSE acquisition and a segmented T1-3D turbo field echo sequence (T1-mVISTA/T1-eTHRIVE). Two radiologists independently analyzed the aorta for concentric contrast enhancement, concentric wall thickening, image quality, and flow artifact intensity (CCE/CWT/IQ/FAI; 4-point scales). The mean aortic wall thickness (MAWT) in post-contrast T1-mVISTA was compared between patients and controls. RESULTS: IQ of T1-mVISTA was rated good to excellent in 91.5% of 282 evaluated vessel segments with no or minor FAI present in 85.5%. The inter-observer reproducibility for the identification of CCE/CWT on T1-mVISTA was 0.92 and 0.93 (p < 0.001). The distribution of segmental inflammation in T1-mVISTA significantly correlated with T1-eTHRIVE (CCE, κ = 0.768; CWT, κ = 0.715; p < 0.001), resulting in a sensitivity, specificity, and positive predictive value of 100%, 81.3%, and 83.3%. The MAWT significantly differed between patients and controls (3.29 ± 0.81 vs. 2.24 ± 0.45 mm; p < 0.001). CONCLUSIONS: T1-mVISTA enables the evaluation of the MAWT and allows the detection of abdominal LVV. KEY POINTS: • 3D T1w-mVISTA accurately depicted the large abdominal vessels. • 3D T1w-mVISTA enables accurate measurements of the abdominal aortic wall thickness. • 3D T1w-mVISTA is useful for the detection of abdominal LVV.


Assuntos
Imageamento por Ressonância Magnética/métodos , Vasculite/diagnóstico por imagem , Abdome/irrigação sanguínea , Abdome/diagnóstico por imagem , Adulto , Idoso , Aorta Abdominal/diagnóstico por imagem , Aortite/diagnóstico por imagem , Artefatos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Q J Nucl Med Mol Imaging ; 64(2): 194-202, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29307167

RESUMO

BACKGROUND: We aimed to investigate the clinical value of a 3D-T1w turbo-spin-echo (TSE) sequence and [18F]fluorodeoxyglucose positron emission tomography/computed tomography ([18F]FDG-PET/CT) for the diagnosis of active large vessel vasculitis (LVV) and single-organ vasculitis (SOV) of the aorta. METHODS: Twenty-four patients with suspected vasculitis who underwent MRI and PET/CT were retrospectively evaluated. MRI was analyzed for concentric contrast enhancement and wall thickening, and flow artifact intensity (4-point-scales). PET/CT analysis comprised qualitative, quantitative and semiquantitative methods. Imaging findings were correlated with final diagnosis derived from the clinical follow-up data. RESULTS: Fifteen of 24 patients had a clinically confirmed active vasculitis, two had inactive vasculitis and 7 no vasculitis. [18F]FDG-PET/CT and 3D-T1w TSE-MRI revealed both a high diagnostic accuracy of 88% and 83%, respectively. In patients in whom both PET/CT and MRI showed concordant findings (19 patients), the accuracy increased to 95% with a high positive predictive value (92%) and negative predictive value (100%); thus, a correct diagnosis was obtained in 18 of 19 patients. Among the five patients with discordant findings PET/CT correctly identified the two patients without active vasculitis while rated false positive on MRI. Of the three remaining patients with active vasculitis, two were correctly identified by MRI and one by PET/CT. CONCLUSIONS: 3D-T1w TSE-MRI and [18F]FDG-PET/CT are both useful in the diagnosis of active vasculitis with high diagnostic accuracies. The diagnostic accuracy was even optimized by combining the two analysis methods. Therefore, there might be substantial potential for the application of whole-body hybrid PET/MRI in the evaluation of vasculitis in future studies.


Assuntos
Aorta/diagnóstico por imagem , Fluordesoxiglucose F18 , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Vasculite/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
Eur Radiol ; 30(2): 866-876, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31691123

RESUMO

OBJECTIVES: To evaluate the diagnostic value of a contrast-enhanced 3D T1-weighted-modified volumetric isotropic turbo spin-echo acquisition sequence (T1-mVISTA) in comparison with a conventional 3D T1-weighted magnetization-prepared rapid gradient-echo (T1-MP-RAGE) sequence for the detection of meningeal enhancement in patients with meningitis. METHODS: Thirty patients (infectious meningitis, n = 12; neoplastic meningitis, n = 18) and 45 matched controls were enrolled in this retrospective case-control study. Sets of randomly selected T1-mVISTA and T1-MP-RAGE images (both with 0.8-mm isotropic resolution) were read separately 4 weeks apart. Image quality, leptomeningeal and dural enhancement, grading of visual contrast enhancement, and diagnostic confidence were compared using the Kruskal-Wallis rank sum test. RESULTS: Image quality was rated to be good to excellent in 75 out of 75 cases (100%) for T1-mVISTA and 74 out of 75 cases (98.7%) for T1-MP-RAGE. T1-mVISTA detected significantly more patients with leptomeningeal enhancement (p = 0.006) compared with T1-MP-RAGE (86.7 vs. 50.0%, p < 0.001), each with specificity of 100%. Similarly, sensitivity of T1-mVISTA for the detection of dural and/or leptomeningeal enhancement was also significantly higher compared with that of T1-MP-RAGE (96.7 vs. 80.0%, p = 0.025) without significant differences regarding specificity (97.8 vs. 95.6%, p = 0.317). No significant differences were found for dural enhancement alone. Diagnostic confidence in T1-mVISTA was significantly higher (p = 0.01). Visual contrast enhancement was tendentially higher in T1-mVISTA. CONCLUSIONS: T1-mVISTA may be an adequate and probably better alternative to T1-MP-RAGE for detection of leptomeningeal diseases. KEY POINTS: • Black-blood T1-mVISTA showed a significant higher sensitivity for the detection of leptomeningeal enhancement compared with MP-RAGE without losses regarding specificity. • Diagnostic confidence was assessed significantly higher in T1-mVISTA. • T1-mVISTA should be considered a supplement or an alternative to T1-MP-RAGE in patients with suspected leptomeningeal diseases.


Assuntos
Neoplasias Meníngeas/diagnóstico por imagem , Meningite/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional/métodos , Lactente , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias Meníngeas/secundário , Meningites Bacterianas/diagnóstico por imagem , Meningite Viral/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
11.
Ultraschall Med ; 40(5): 638-645, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30674040

RESUMO

PURPOSE: To assess the diagnostic value of intima media thickness measurements and contrast-enhanced ultrasound (CEUS) of the supraaortic arteries in the assessment of disease activity in Takayasu arteritis (TA). MATERIALS AND METHODS: Patients with TA and involvement of the carotid and/or subclavian/axillary arteries underwent CEUS imaging in addition to B-mode and color duplex ultrasound. The maximum IMT (mIMT) was measured and high-resolution CEUS of the most prominently thickened vessel segment was performed. Two blinded readers reviewed the CEUS movies, with semiquantitative assessment of microbubble enhancement of the arterial wall (grade 0: no or minimal; grade 1: moderate; grade 2: pronounced). Clinical symptoms, acute phase reactants, and established indices of clinical disease activity (NIH criteria, ITAS score) were recorded. RESULTS: 40 examinations in 17 patients were analyzed. According to clinical judgement, 27 and 13 cases were classified as clinically inactive and active, respectively. An mIMT-cutoff of > 2.7 mm identified active disease with a sensitivity and specificity of 69.2 % and 88.9 %, respectively (area under the curve 0.83). The interobserver agreement of CEUS analysis was substantial (Cohen's kappa 0.76). By consensus reading, 17, 15, and 8 cases were classified as uptake grade 0, grade 1 and grade 2, respectively. Grade 0 uptake was exclusively present in 17 clinically inactive patients. Grade 1 uptake was seen in 10 patients with clinically inactive disease and 5 patients with clinically active disease. Grade 2 uptake was exclusively present in 8 patients with active disease. CONCLUSION: Both sonographic IMT measurements and high-resolution CEUS are promising in the ad-hoc assessment of disease activity in patients with TA.


Assuntos
Meios de Contraste , Arterite de Takayasu , Ultrassonografia/métodos , Adulto , Espessura Intima-Media Carotídea , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Arterite de Takayasu/diagnóstico por imagem , Arterite de Takayasu/patologia
12.
Int J Rheum Dis ; 22(8): 1371-1377, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30565885

RESUMO

AIM: To determine the diagnostic yield of 18 F-fluorodeoxyglucose positron emission tomography (PET) in disease activity assessment of large vessel vasculitides (LVV). METHODS: Patients with LVV who had undergone PET (between 2004 and June 2010) or PET co-registered with computed tomography (PET/CT; since June 2010) were identified. Clinical disease activity was assessed using established scoring systems. PET images were reviewed by two blinded nuclear medicine physicians. Uptake of the aortic wall was compared to the liver uptake utilizing a visual 4-point score, with a vessel wall uptake similar or higher than liver uptake considered as active disease. Various target-to-background ratios were calculated. Receiver operator characteristics analysis was applied to determine the diagnostic accuracy of PET for detecting clinically active disease. Interobserver agreement of visual readings was measured with Cohen´s kappa. RESULTS: Eighty examinations in 62 patients were analyzed, with a mean time between diagnosis and PET of 106 ± 171 weeks. Fifty-seven cases were finally classified as clinically active and 23 cases as clinically inactive. With a cut-off value of 1.3, the aorta-to-liver ratio yielded a sensitivity and specificity of 84.2% and 82.6% (area under the curve 0.9). Overall, sensitivity and specificity of visual analysis were 68.4% and 91.3%, but sensitivity decreased to 54% in patients treated for more than 3 months. Interobserver agreement of visual rating was excellent (κ: 0.93). CONCLUSION: Positron emission tomography is specific and reliable in disease activity assessment of LVV, but lacks sensitivity for detecting active disease in patients under long-term immunosuppressive treatment.


Assuntos
Aorta/diagnóstico por imagem , Arterite de Células Gigantes/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Arterite de Takayasu/diagnóstico por imagem , Biomarcadores/sangue , Bases de Dados Factuais , Feminino , Fluordesoxiglucose F18/administração & dosagem , Arterite de Células Gigantes/sangue , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Arterite de Takayasu/sangue
13.
Invest Radiol ; 53(11): 698-704, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30095558

RESUMO

OBJECTIVES: Arteritic anterior ischemic optic neuropathy (A-AION) caused by inflammatory occlusion of the posterior ciliary arteries is the most common reason for irreversible vision loss in patients with giant cell arteritis. Atypical clinical presentation and negative funduscopy can delay systemic high-dose corticosteroid therapy to prevent impending permanent blindness and involvement of the contralateral eye.The purpose of this study was to assess the diagnostic accuracy of 3-dimensional (3D) high-resolution T1-weighted black-blood magnetic resonance imaging (T1-BB-MRI) for the detection of posterior ciliary artery involvement in patients with giant cell arteritis and funduscopic A-AION. MATERIALS AND METHODS: After institutional review board approval and informed consent, 27 patients with suspected giant cell arteritis and vision disturbances were included in this monocentric prospective cohort study. Giant cell arteritis was diagnosed in 18 patients according to the diagnostic reference standard (6 men, 73.8 [69.0-78.0] years); 14 of those were positive for A-AION. Precontrast and postcontrast 3D T1-BB-MRI was performed in all 27 patients. Two radiologists separately assessed image quality and local fat suppression (4-point scale), visual contrast enhancement (3-point scale), and diagnostic confidence (5-point scale) regarding arteritic posterior ciliary artery involvement. Magnetic resonance imaging findings were assessed in comparison to funduscopy. Statistical analysis included accuracy parameters and interrater agreement. RESULTS: Sensitivity of 3D T1-BB-MRI was 92.9% (95% confidence interval, 66.1%-99.8%) and specificity was 92.3% (95% confidence interval, 64.0%-99.8%) for detection of A-AION-positive patients. Image quality and local fat suppression were assessed with 3.2 ± 0.8 (median 3) and 3.8 ± 0.5 (median 4). Visual contrast enhancement with 2.3 ± 0.8 (median 3) and diagnostic confidence was rated at 4.7 ± 0.5 (median 5). Interrater agreement was high (κ = 0.85, P < 0.001). Three-dimensional T1-BB-MRI displayed bilateral findings in 50% of the cases, whereas only unilateral A-AION was detected in funduscopy as a possible indication for the contralateral eye at risk. CONCLUSIONS: Three-dimensional T1-BB-MRI allows accurate detection of arteritic posterior ciliary artery involvement in patients with A-AION. Further, 3D T1-BB-MRI seems to display arteritic involvement of the posterior ciliary arteries earlier than funduscopy and might, therefore, display "vision-at-risk" in patients with visual impairment and suspected giant cell arteritis but unremarkable funduscopy.


Assuntos
Arterite de Células Gigantes/complicações , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuropatia Óptica Isquêmica/complicações , Neuropatia Óptica Isquêmica/diagnóstico por imagem , Idoso , Estudos de Coortes , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Nervo Óptico/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Invest Radiol ; 53(1): 13-19, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28858894

RESUMO

OBJECTIVES: The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS). MATERIALS AND METHODS: After institutional review board approval and informed consent, 22 patients (8 men; aged 31.0 ± 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study.Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm resolution (T1-mVISTA_1.0). Reference lesions were defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests. RESULTS: Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions were significantly increased in T1-mVISTA compared with MP-RAGE (P < 0.001). Significantly more contrast-enhancing lesions were detected with T1-mVISTA than with MP-RAGE (71 vs 39, respectively; P < 0.001). With MP-RAGE, 25.6% of lesions were missed in the initial reading, whereas only 4.2% of lesions were missed with T1-mVISTA. Increase of the voxel volume from 0.8 mm to 1.0 mm isotropic in T1-mVISTA_1.0 did not affect the detectability of lesions, whereas scan time was decreased from 4:43 to 1:55 minutes. CONCLUSIONS: Three-dimensional T1-mVISTA improves the detection rates of contrast-enhancing cerebral MS lesions compared with conventional 3D MP-RAGE sequences by increasing CNR of lesions and might, therefore, be useful in patient management.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Estudos de Coortes , Feminino , Humanos , Masculino , Esclerose Múltipla Recidivante-Remitente/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes
15.
Vasa ; 47(2): 149-152, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29271720

RESUMO

Takayasu arteritis (TA) is a rare large vessel vasculitis, affecting the aorta and its major branches, typically in young women. In this case report, we present three cases of young women of Caucasian descent who experienced relapses while under treatment with the monoclonal humanized antibody to the interleukin 6 receptor, tocilizumab. Active vasculitic lesions of the supraaortic (common carotid and axillary) arteries were detected and characterized via high resolution contrast enhanced ultrasound. Based on these cases, we discuss the potential role of contrast enhanced ultrasound in the diagnosis and follow-up of TA as well as the current data on the efficacy of tocilizumab in the treatment of TA.


Assuntos
Anti-Inflamatórios/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Artéria Axilar/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Fosfolipídeos/administração & dosagem , Hexafluoreto de Enxofre/administração & dosagem , Arterite de Takayasu/diagnóstico por imagem , Arterite de Takayasu/tratamento farmacológico , Ultrassonografia Doppler em Cores , Adulto , Feminino , Humanos , Valor Preditivo dos Testes , Recidiva , Arterite de Takayasu/imunologia , Resultado do Tratamento , Adulto Jovem
16.
Rofo ; 189(7): 624-631, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28445914

RESUMO

Purpose Recent studies have suggested that intraluminal thrombi show contrast enhancement on carotid black-blood T1w MRI. The aim of this study was to evaluate the significance of intraluminal contrast enhancement (iCE) regarding symptom status in patients with spontaneous cervical artery dissection (sCAD). Methods 33 consecutive patients (19 men) with sCAD received a brain MRI (DIFF, T2w, T2*w, FLAIR) and a multi-sequence 3T-MRI with fat-saturated high-resolution black-blood T1w-sequences pre- and post-contrast, contrast-enhanced MR angiography and TOF images of carotid and vertebral arteries. Presence/absence of iCE, vessel occlusion and vessel wall hematoma (hyperintense in T1w pre-contrast) were analysed by two radiologists in consensus decision. Results 44 of 132 analysed vessels had a vessel wall hematoma, consistent with sCAD. In 17 of 44 dissected vessels an acute ischemic stroke was found. 16 of 17 (94.1 %) vessels ipsilateral to ischemic stroke demonstrated iCE, compared to 9 of 44 (20.4 %) dissected vessels without stroke (P< 0.001). The presence/absence of iCE resulted in a sensitivity, specificity, positive and negative predictive value and accuracy for ischemic stroke of 0.94, 0.67, 0.64, 0.95, and 0.77, respectively, and an odds ratio of 32.0. Conclusion iCE, which is suggestive of intraluminal thrombus formation, is strongly correlated with ischemic symptoms in patients with sCAD. Key points · Intraluminal contrast enhancement is associated with cerebral ischemia in corresponding vessel territories in patients with cervical artery dissection.. · Our results suggest that intraluminal contrast enhancement represents intraluminal thrombus formation.. · Black-blood imaging might be useful to identify those patients with cervical artery dissection at higher risk for initial or recurrent stroke.. Citation Format · Coppenrath E, Lenz O, Sommer N et al. Clinical Significance of Intraluminal Contrast Enhancement in Patients with Spontaneous Cervical Artery Dissection: A Black-Blood MRI Study. Fortschr Röntgenstr 2017; 189: 624 - 631.


Assuntos
Dissecação da Artéria Carótida Interna/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Dissecação da Artéria Vertebral/diagnóstico por imagem , Adulto , Idoso , Dissecação da Artéria Carótida Interna/complicações , Infarto Cerebral/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Fatores de Risco , Sensibilidade e Especificidade , Dissecação da Artéria Vertebral/complicações
17.
Clin Exp Rheumatol ; 35 Suppl 103(1): 128-133, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28375835

RESUMO

OBJECTIVES: We aimed to determine the diagnostic accuracy of B-mode compression sonography of the temporal arteries (tempCS) and B-mode sonographic measurement of the axillary artery intima media thickness (axIMT) for the diagnosis of giant cell arteritis (GCA). METHODS: After having established measurement of tempCS and axIMT in our routine diagnostic workup, 92 consecutive patients with a suspected diagnosis of GCA were investigated. Clinical characteristics were recorded and wall thickening of the temporal arteries (tempCS) and axillary arteries (axIMT) was measured (mm). Using the final clinical diagnosis as the reference standard, receiver operator characteristics (ROC) analysis was performed. In a subgroup of 26 patients interobserver agreement was assessed using Spearman's rank correlation. RESULTS: Cranial GCA, extracranial GCA, and combined cranial/extracranial GCA were diagnosed in 18, 7, and 9 individuals, respectively. For the diagnosis of cranial GCA, tempCS had an excellent area under the curve (AUC) of 0.95, with a cut-off of ≥0.7 mm offering a sensitivity and specificity of 85% and 95%. The AUC of axIMT for the diagnosis of extracranial GCA was 0.91 (cut-off ≥1.2 mm: sensitivity and specificity 81.3 and 96.1%). Applying a combined tempCS/axIMT cut-off of ≥0.7mm/1.2 mm, we calculated an overall sensitivity and specificity for the final clinical diagnosis of cranial and/or extracranial GCA of 85.3% and 91.4%. Interobserver agreement was strong for both parameters assessed (Spearman's rho 0.72 and 0.77, respectively). CONCLUSIONS: The combination of tempCS/axIMT allows objective sonographic assessment in suspected GCA with promising diagnostic accuracy.


Assuntos
Artéria Axilar/diagnóstico por imagem , Arterite de Células Gigantes/diagnóstico por imagem , Artérias Temporais/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Eur Radiol ; 27(9): 3947-3955, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28168366

RESUMO

OBJECTIVE: To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. METHODS: Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. RESULTS: Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P < 0.001) and the TLR_12M rates (IW: 8 (13.3%); OC: 19 (27.5%); CC: 27 (54.0%); P < 0.001) differed significantly, as did the subgroup analyses (DBM: P = 0.05; RR: P = 0.003; HLP: P = 0.005; CAD: P = 0.02; localization: P < 0.001; calcification: P < 0.001), with the best patency for the IW stent and the highest TLR_12M for the CC stent. CONCLUSION: The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. KEY POINTS: • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.


Assuntos
Angioplastia/instrumentação , Arteriopatias Oclusivas/cirurgia , Artéria Femoral/cirurgia , Artéria Poplítea/cirurgia , Stents , Idoso , Ligas/uso terapêutico , Angioplastia/métodos , Angioplastia com Balão/métodos , Arteriopatias Oclusivas/patologia , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Doença Arterial Periférica/patologia , Doença Arterial Periférica/cirurgia , Desenho de Prótese , Reperfusão/métodos , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia
19.
Eur Radiol ; 27(5): 2119-2128, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27510630

RESUMO

OBJECTIVES: To evaluate the feasibility of T1w-3D black-blood turbo spin echo (TSE) sequence with variable flip angles for the diagnosis of thoracic large vessel vasculitis (LVV). METHODS: Thirty-five patients with LVV, diagnosed according to the current standard of reference, and 35 controls were imaged at 3.0T using 1.2 × 1.3 × 2.0 mm3 fat-suppressed, T1w-3D, modified Volumetric Isotropic TSE Acquisition (mVISTA) pre- and post-contrast. Applying a navigator and peripheral pulse unit triggering (PPU), the total scan time was 10-12 min. Thoracic aorta and subclavian and pulmonary arteries were evaluated for image quality (IQ), flow artefact intensity, diagnostic confidence, concentric wall thickening and contrast enhancement (CWT, CCE) using a 4-point scale. RESULTS: IQ was good in all examinations (3.25 ± 0.72) and good to excellent in 342 of 408 evaluated segments (83.8 %), while 84.1 % showed no or minor flow artefacts. The interobserver reproducibility for the identification of CCE and CWT was 0.969 and 0.971 (p < 0.001) with an average diagnostic confidence of 3.47 ± 0.64. CCE and CWT were strongly correlated (Cohen's k = 0.87; P < 0.001) and significantly more frequent in the LVV-group (52.8 % vs. 1.0 %; 59.8 % vs. 2.4 %; P < 0.001). CONCLUSIONS: Navigated fat-suppressed T1w-3D black-blood MRI with PPU-triggering allows diagnosis of thoracic LVV. KEY POINTS: • Cross-sectional imaging is frequently applied in the diagnosis of LVV. • Navigated, PPU-triggered, T1w-3D mVISTA pre- and post contrast takes 10-12 min. • In this prospective, single-centre study, T1w-3D mVISTA accurately depicted large thoracic vessels. • T1w-3D mVISTA visualized CWT/CCW as correlates of mural inflammation in LVV. • T1w-3D mVISTA might be an alternative diagnostic tool without ionizing radiation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Vasculite/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aortite/diagnóstico por imagem , Artefatos , Estudos de Viabilidade , Feminino , Arterite de Células Gigantes/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Artéria Subclávia/diagnóstico por imagem , Arterite de Takayasu/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia Doppler Dupla/métodos , Adulto Jovem
20.
Eur Radiol ; 26(7): 2359-68, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26431708

RESUMO

OBJECTIVES: Vascular closure devices can accelerate haemostasis after arteriotomy, but induce scarring. The aim of the study was to prospectively analyse the feasibility of a novel biodegradable arterial closure device (CD). METHODS: Two hundred fifty-five patients (183 male; age 36-98 years) with an access vessel diameter >3 mm received the biodegradable CD after endovascular therapy. Technical success rate, time-to-haemostasis (TTH) and time-to-ambulation (TTA) were measured. Puncture site complications were categorized as minor (local hematoma, minor bleeding) or major (pseudoaneurysm, embolization, dissection, thrombotic occlusion, hematoma/major bleeding requiring surgery, access site infection). RESULTS: Technical success was achieved in 98.8 % (252 cases); device failure occurred in three cases (1.2 %). The average TTH and TTA were 11.3 ± 26.9 s and 73.0 ± 126.3 min. The major complication rate was 1.6 %, with three pseudoaneurysms and one retroperitoneal bleeding. The minor complication rate was 2.0 %, with five small hematomas. Neither cardiovascular risk factors nor access vessel characteristics had statistically significant influence on adverse events. Re-puncture was uncomplicated in 32 cases after 155.0 ± 128.8 days. CONCLUSIONS: Handling of the new biodegradable CD is safe. The complication rates are tolerably low and comparable to other CDs. Post-procedural sonography showed no significant palpable subcutaneous changes in the access site. KEY POINTS: • VCDs can increase time efficiency and patient comfort after intervention. • In this prospective single-centre-study, biodegradable CD was safe and easily applicable. • Its major and minor complication rates are comparable to other CDs. • Its mean time-to-haemostasis and time-to-ambulation were 11.3 ± 26.9 s and 73.0 ± 126.3 min. • Post-procedural sonography showed no significant palpable subcutaneous changes at the access site.


Assuntos
Artéria Femoral/cirurgia , Técnicas Hemostáticas/instrumentação , Dispositivos de Oclusão Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...