Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Case Rep Radiol ; 2016: 1780909, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27800204

RESUMO

The evaluation of pulmonary veins during cross-sectional imaging of the chest and the knowledge of their embryology and anatomy are useful for detecting congenital conditions that may be clinically significant. Moreover, with the spread of cross-sectional imaging it is very frequent to find anatomical variants; therefore the radiologist should easily recognize their appearances. This case report shows a left-side upper partial anomalous pulmonary venous return (PAPVR) through a "curved" vein that joins the left brachiocephalic vein, in a female patient who underwent whole-body computed tomography (CT) for staging endometrial cancer. This was an incidental finding, not related to any symptoms; however, we explain the anatomical aspects of this abnormality within the congenital condition of PAPVR and its possible clinical relevance.

2.
Am J Cardiol ; 113(3): 422-8, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24315112

RESUMO

Disparities in the risk of coronary artery disease (CAD) between races may be influenced by differences in the thoracic adipose tissue. We compared computed tomography (CT)-derived volumes of epicardial adipose tissue (EAT), mediastinal adipose tissue (MAT), and pericoronary fat thickness (PFT) and correlations with CAD between black and white patients. This institutional review board-approved Health Insurance Portability and Accountability Act-compliant study included 372 age- and gender-matched black versus white patients (186 black, 54 ± 11 years, 50% men; 186 white, 54 ± 11 years, 50% men) who underwent CT for chest pain evaluation. EAT, MAT, and PFT were measured. The amount of coronary calcium was quantified as calcium score. CAD was defined as ≥50% coronary artery narrowing. EAT and MAT volumes were significantly lower in black than white patients (59 [twenty-fifth to seventy-fifth percentile 39 to 84] vs 97 [67 to 132] cm(3) and 44 [27 to 77] vs 87 [52 to 157] cm(3), for both p <0.001). Mean PFT in black patients was slightly lower than white patients (17.2 ± 3.2 vs 18.1 ± 3.4 mm, p <0.01). The relation between race and extent of adipose tissue remained significant after adjustment for cardiovascular risk factors. Significant correlations were observed between EAT and MAT volumes and calcium score in black and white patients (r = 0.19 to 0.26, p <0.01). For both races, the level of thoracic fat measurements was higher in present versus absent coronary calcification. A greater amount of thoracic fat was found with obstructive CAD only in white patients. In conclusion, CT-derived measurements of thoracic fat differ between symptomatic black and white patients, suggesting a differential relation between thoracic adipose tissue and CAD pathophysiology by race.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Negro ou Afro-Americano , Dor no Peito/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , População Branca , Doença Aguda , Dor no Peito/etnologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estados Unidos/epidemiologia
3.
Atherosclerosis ; 229(2): 443-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23880201

RESUMO

Chest pain associated with cocaine use represents an increasing problem in the emergency department (ED). Cocaine use has been linked to the acute coronary syndrome (ACS) and acute myocardial infarction (AMI). We used coronary computed tomography angiography (cCTA) to evaluate the prevalence, severity and composition of atherosclerotic lesions in cocaine users. We studied 78 patients with non-occasional cocaine use (52 men, 44 ± 7 years, 23 under the acute influence) and acute chest pain but without ACS, who had undergone cCTA in the ED. Patients were matched one-to-one by gender, race, symptoms, and risk-factors with a control cohort (n = 78; 52 men, 45 ± 6 years) not using cocaine. Each coronary segment was evaluated for the presence and composition (calcified, non-calcified, partially calcified) of atherosclerotic plaque and for stenosis. The prevalence of coronary stenosis was not significantly different between patients with and without cocaine use (13% versus 5%, P > 0.05). However, cocaine users on average had significantly more atherosclerotic plaques (0.44 ± 0.88 versus 0.29 ± 0.83, P < 0.05) and a tendency towards more calcified (0.64 ± 1.23 versus 0.55 ± 1.22, P > 0.05) and non-calcified plaques (0.26 ± 0.63 versus 0.17 ± 0.57, P > 0.05), yet not reaching statistical significance. Furthermore, cocaine users had significantly more partially calcified plaques (0.41 ± 0.61 versus 0.17 ± 0.41, P < 0.05) and higher partially calcified plaque volume (59.7 ± 33.3 mm(3) versus 25.6 ± 12.6 mm(3), P < 0.05). Thus, cocaine users tend to have more pronounced coronary atherosclerosis compared to patients without cocaine use at the time of presentation with acute chest pain.


Assuntos
Transtornos Relacionados ao Uso de Cocaína/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/epidemiologia , Tomografia Computadorizada por Raios X , Dor Aguda/epidemiologia , Adulto , Negro ou Afro-Americano/estatística & dados numéricos , Dor no Peito/epidemiologia , Feminino , Humanos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , População Branca/estatística & dados numéricos
4.
Acta Radiol ; 54(3): 249-58, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23446750

RESUMO

Significant literature on MDCT coronary angiography (MDCT-CA) has emerged in the last decade concerning patient's selection, technical aspects of different generations of CT equipment, ECG gating, contrast material and beta-blockade administration, acquisition parameters, and radiation dose. However, the literature regarding postprocessing, reading, and reporting is not so extensive. This review highlights the main elements of MDCT-CA data analysis, thereby allowing the radiologist to take full advantage of this technology and enable a structured report to be generated, promoting best practice with high-quality results.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Técnicas de Imagem de Sincronização Cardíaca , Humanos , Sistemas de Informação em Radiologia , Software
5.
Eur Radiol ; 23(5): 1306-15, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23207869

RESUMO

OBJECTIVES: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. METHODS: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. RESULTS: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. CONCLUSIONS: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. KEY POINTS: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.


Assuntos
Doenças Cardiovasculares/congênito , Doenças Cardiovasculares/diagnóstico por imagem , Angiografia Coronária/métodos , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Eur J Radiol ; 82(2): 270-4, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23137919

RESUMO

OBJECTIVE: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. MATERIALS AND METHODS: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.2 ± 9.8 years) who had undergone second generation dual-source cardiac CT with 120 kV, 175-426 mAs, and 500 ms gantry rotation. All data were reconstructed with a temporal resolution of 250 ms using traditional filtered-back projection (FBP) and of 200 ms using the TRIM-algorithm. Contrast attenuation and contrast-to-noise-ratio (CNR) were measured in the ascending aorta. The presence and severity of coronary motion artifacts was rated on a 4-point Likert scale. RESULTS: All scans were considered of diagnostic quality. Mean BMI was 36 ± 3.6 kg/m(2). Average heart rate was 60 ± 9 bpm. Mean effective dose was 13.5 ± 4.6 mSv. When comparing FBP- and TRIM reconstructed series, the attenuation within the ascending aorta (392 ± 70.7 vs. 396.8 ± 70.1 HU, p>0.05) and CNR (13.2 ± 3.2 vs. 11.7 ± 3.1, p>0.05) were not significantly different. A total of 110 coronary segments were evaluated. All studies were deemed diagnostic; however, there was a significant (p<0.05) difference in the severity score distribution of coronary motion artifacts between FBP (median=2.5) and TRIM (median=2.0) reconstructions. CONCLUSION: The algorithm evaluated here delivers diagnostic imaging quality of the coronary arteries despite 500 ms gantry rotation. Possible applications include improvement of cardiac imaging on slower gantry rotation systems or mitigation of the trade-off between temporal resolution and CNR in obese patients.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Eur Radiol ; 23(1): 125-32, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22777622

RESUMO

OBJECTIVES: Comparison of coronary artery stent assessment with cardiac CT angiography (cCTA) using traditional filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE), in both full- and half-radiation dose image data. METHODS: Dual-source cCTA studies of 37 implanted stents were reconstructed at full- and half-radiation dose with FBP and SAFIRE. Half-dose data were based on projections from one DSCT detector. In-stent noise, signal-to-noise ratio (SNR), and stent-lumen attenuation increase ratio (SAIR) were measured and image quality graded. Stent volumes were measured to gauge severity of beam hardening artefacts. RESULTS: Full-dose SAFIRE reconstructions were superior to full-dose FBP vis-à-vis in-stent noise (21.2 ± 6.6 vs. 35.7 ± 17.5; P < 0.05), SNR (22.1 ± 8.6 vs. 14.3 ± 6.7; P < 0.05), SAIR (19.6 ± 17.6 vs. 33.4 ± 20.4%; P < 0.05), and image quality (4.2 ± 0.86 vs. 3.5 ± 1.0; P < 0.05). Stent volumes were lower measured with SAFIRE (119.9 ± 53.7 vs. 129.8 ± 65.0 mm(3); P > 0.05). Comparing half-dose SAFIRE with full-dose FBP, in-stent noise (26.7 ± 13.0 vs. 35.7 ± 17.5; P < 0.05) and SNR (18.2 ± 6.9 vs. 14.3 ± 6.7; P < 0.05) improved significantly. SAIR (31.6 ± 24.3 vs. 33.4 ± 20.4%; P > 0.05), stent volume (129.6 ± 57.3 vs. 129.8 ± 65.0 mm(3); P > 0.05), and image quality (3.5 ± 1.0 vs. 3.7 ± 1.1; P > 0.05) did not differ. Radiation dose decreased from 8.7 ± 5.2 to 4.3 ± 2.6 mSv. CONCLUSIONS: Iterative reconstruction significantly improves imaging of coronary artery stents by CT compared with FBP, even with half-radiation-dose data.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Distribuição de Qui-Quadrado , Comorbidade , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Estatísticas não Paramétricas
8.
Meat Sci ; 86(3): 839-44, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20678868

RESUMO

An experimental investigation was carried out to study the evolution of the volatile compounds of ripened sausages as a function of both storage time (time) and composition of packaging atmosphere (MAP). Ripened sausages, prepared at an industrial plant, were packed applying three different atmosphere compositions and were stored for three months. The obtained data evinced that the evolution of the volatile compounds was significantly related to the variable time more than to the variable MAP. The main volatile compounds were those derived from spices. Among them, Δ3-carene was the most abundant and a significant decrease was observed during storage (p<0.05). The volatile compounds derived from lipid autoxidation showed generally a significant increase during storage, suggesting the raise of lipid oxidation also at low oxygen concentration. Moreover, octanal and nonanal were significantly influenced by the atmosphere composition, with the highest values in samples packed at the lowest CO2 concentration.


Assuntos
Manipulação de Alimentos/métodos , Embalagem de Alimentos/métodos , Produtos da Carne/análise , Compostos Orgânicos Voláteis/análise , Aldeídos/análise , Animais , Atmosfera , Monoterpenos Bicíclicos , Compostos Bicíclicos com Pontes/análise , Dióxido de Carbono , Peroxidação de Lipídeos , Oxigênio , Especiarias , Suínos , Fatores de Tempo , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...