1.
MMWR CDC Surveill Summ ; 43(1): 9-17, 1994 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-8208239

RESUMO

PROBLEM/CONDITION: A case of occupational asthma is a sentinel health event indicating a need for preventive intervention. REPORTING PERIOD COVERED: 1988-1992. DESCRIPTION OF SYSTEMS: As part of the Sentinel Event Notification System for Occupational Risks (SENSOR) Program, initiated by CDC's National Institute for Occupational Safety and Health in 1987, state-based surveillance and intervention programs for occupational asthma (OA) have been under development in Michigan and New Jersey. The initial 5-year projects in these states have been completed. RESULTS: From 1988 through 1992, the SENSOR programs in these states identified a total of 535 cases of occupational asthma and related conditions. Of these 535 cases, 328 cases met the SENSOR surveillance case definition for OA. In addition, 128 cases were classified as possible OA, 42 as reactive airways dysfunction syndrome, and 37 as occupationally aggravated asthma. In both Michigan and New Jersey, manufacturing was the industrial sector with the largest proportion of cases. In Michigan, > 40% of the case-patients worked in transportation equipment manufacturing. In New Jersey, 15% of case-patients worked in manufacturing of chemicals and allied products. Overall, isocyanates were the most frequently reported asthma-causing agents (19.4% of cases). Follow-up industrial hygiene sampling measured suspect agents at airborne concentrations generally below the permissible exposure limits established by the Occupational Safety and Health Administration. INTERPRETATION: In its first 5 years, the SENSOR system has led to the identification of previously unrecognized causes of occupational asthma. Overall findings indicate the need for more comprehensive control of such well-known occupational allergens as the isocyanates. In addition, SENSOR interventions have prompted improvements in protection for workers. ACTIONS TAKEN: Approaches to state-based surveillance and intervention for OA are being developed through newly funded 5-year SENSOR projects in four states (California, Massachusetts, Michigan, and New Jersey). The goal is to develop a model for effective state-based OA surveillance that can be applied by any state health department.


Assuntos
Asma/epidemiologia , Doenças Profissionais/epidemiologia , Vigilância da População , Asma/prevenção & controle , Humanos , Michigan/epidemiologia , New Jersey/epidemiologia , Doenças Profissionais/prevenção & controle , Vigilância da População/métodos
2.
Chest ; 100(6): 1515-21, 1991 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1835690

RESUMO

The purpose of this study was to identify the strengths and limitations of using portable peak flowmeters to document suspected cases of occupational asthma that were reported to a statewide surveillance project. The New Jersey Department of Health conducts surveillance for occupational asthma as part of the federally sponsored Sentinel Event Notification System for Occupational Risks (SENSOR). Between May 1988 and January 1990, 70 cases were reported voluntarily by physicians. Subjects who were still employed in suspected work sites were requested to test themselves for at least 15 days, using portable peak flowmeters to generate serial measurements of their peak expiratory flow rate (PEFR). For each of the 14 subjects who were successfully tested, the PEFR data provided valuable information about their asthma-work association. However, a large number of subjects whose cases were reported (56) either could not be tested or were not successfully tested. The proportion of subjects completing the test would probably improve if it were conducted when their conditions were first diagnosed. Accordingly, the collection of serial peak flow measurements to document occupational asthma would best be initiated by the treating physician when the patient first sought care, rather than waiting until after the case was reported to the state health department.


Assuntos
Asma/diagnóstico , Doenças Profissionais/diagnóstico , Testes de Função Respiratória/instrumentação , Reologia , Adulto , Asma/etiologia , Ritmo Circadiano , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ocupações , Pico do Fluxo Expiratório