Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Air Waste Manag Assoc ; 68(5): 494-510, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29341854

RESUMO

The replacement of the Desert Research Institute (DRI) model 2001 with model 2015 thermal/optical analyzers (TOAs) results in continuity of the long-term organic carbon (OC) and elemental carbon (EC) database, and it adds optical information with no additional carbon analysis effort. The value of multiwavelength light attenuation is that light absorption due to black carbon (BC) can be separated from that of brown carbon (BrC), with subsequent attribution to known sources such as biomass burning and secondary organic aerosols. There is evidence of filter loading effects for the 25% of all samples with the highest EC concentrations based on the ratio of light attenuation to EC. Loading corrections similar to those used for the seven-wavelength aethalometer need to be investigated. On average, nonurban Interagency Monitoring of PROtected Visual Environments (IMPROVE) samples show higher BrC fractions of short-wavelength absorption than urban Chemical Speciation Network (CSN) samples, owing to greater influence from biomass burning and aged aerosols, as well as to higher primary BC contributions from engine exhaust at urban sites. Sequential samples taken during an Everglades National Park wildfire demonstrate the evolution from flaming to smoldering combustion, with the BrC fraction increasing as smoldering begins to dominate the fire event. IMPLICATIONS: The inclusion of seven wavelengths in thermal/optical carbon analysis of speciated PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 µm) samples allows contributions from biomass burning and secondary organic aerosols to be estimated. This separation is useful for evaluating control strategy effectiveness, identifying exceptional events, and determining natural visibility conditions.


Assuntos
Carbono/análise , Monitoramento Ambiental/métodos , Material Particulado/análise , Fuligem/análise , Aerossóis/análise , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Biomassa , Carbono/química , Tamanho da Partícula , Material Particulado/química , Fuligem/química , Emissões de Veículos/análise , Incêndios Florestais
2.
Anal Bioanal Chem ; 401(10): 3141-52, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21626190

RESUMO

Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Métodos Analíticos de Preparação de Amostras/normas , Carbono/análise , Métodos Analíticos de Preparação de Amostras/instrumentação , Métodos Analíticos de Preparação de Amostras/métodos , Controle de Qualidade
3.
J Air Waste Manag Assoc ; 57(9): 1014-23, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17912920

RESUMO

Thermally derived carbon fractions including organic carbon (OC) and elemental carbon (EC) have been reported for the U.S. Interagency Monitoring of PROtected Visual Environments (IMPROVE) network since 1987 and have been found useful in source apportionment studies and to evaluate quartz-fiber filter adsorption of organic vapors. The IMPROVE_A temperature protocol defines temperature plateaus for thermally derived carbon fractions of 140 degrees C for OC1, 280 degrees C for OC2, 480 degrees C for OC3, and 580 degrees C for OC4 in a helium (He) carrier gas and 580 degrees C for EC1, 740 degrees C for EC2, and 840 degrees C for EC3 in a 98% He/2% oxygen (O2) carrier gas. These temperatures differ from those used previously because new hardware used for the IMPROVE thermal/optical reflectance (IMPROVE_TOR) protocol better represents the sample temperature than did the old hardware. A newly developed temperature calibration method demonstrates that these temperatures better represent sample temperatures in the older units used to quantify IMPROVE carbon fractions from 1987 through 2004. Only the thermal fractions are affected by changes in temperature. The OC and EC by TOR are insensitive to the change in temperature protocol, and therefore the long-term consistency of the IMPROVE database is conserved. A method to detect small quantities of O2 in the pure He carrier gas shows that O2 levels above 100 ppmv also affect the comparability of thermal carbon fractions but have little effect on the IMPROVE_TOR split between OC and EC.


Assuntos
Carbono/análise , Monitoramento Ambiental , Poluição Ambiental/análise , Temperatura , Atmosfera/química , Calibragem , Carbono/química , Bases de Dados Factuais , Oxigênio/análise
4.
J Air Waste Manag Assoc ; 56(4): 474-91, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16681212

RESUMO

Results from six continuous and semicontinuous black carbon (BC) and elemental carbon (EC) measurement methods are compared for ambient samples collected from December 2003 through November 2004 at the Fresno Supersite in California. Instruments included a multi-angle absorption photometer (MAAP; lambda = 670 nm); a dual-wavelength (lambda = 370 and 880 nm) aethalometer; seven-color (lambda = 370, 470, 520, 590, 660, 880, and 950 nm) aethalometers; the Sunset Laboratory carbon aerosol analysis field instrument; a photoacoustic light absorption analyzer (lambda = 1047 nm); and the R&P 5400 ambient carbon particulate monitor. All of these acquired BC or EC measurements over periods of 1 min to 1 hr. Twenty-four-hour integrated filter samples were also acquired and analyzed by the Interagency Monitoring of Protected Visual Environments (IMPROVE) thermal/optical reflectance carbon analysis protocol. Site-specific mass absorption efficiencies estimated by comparing light absorption with IMPROVE EC concentrations were 5.5 m2/g for the MAAP, 10 m2/g for the aethalometer at a wavelength of 880 nm, and 2.3 m2/g for the photoacoustic analyzer; these differed from the default efficiencies of 6.5, 16.6, and 5 m2/g, respectively. Scaling absorption by inverse wavelength did not provide equivalent light absorption coefficients among the instruments for the Fresno aerosol measurements. Ratios of light absorption at 370 nm to those at 880 nm from the aethalometer were nearly twice as high in winter as in summer. This is consistent with wintertime contributions from vehicle exhaust and from residential wood combustion, which is believed to absorb more shorter-wavelength light. To reconcile BC and EC measurements obtained by different methods, a better understanding is needed of the wavelength dependence of light-absorption and mass-absorption efficiencies and how they vary with different aerosol composition.


Assuntos
Poluentes Ocupacionais do Ar/análise , Carbono/análise , Monitoramento Ambiental/métodos , Filtração , Estações do Ano , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...