Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J AOAC Int ; 95(2): 307-12, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22649911

RESUMO

At the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," on June 29, 2011, an Expert Review Panel agreed that the method "Determination of Vitamin B12 in Infant Formulas and Adult Nutritionals by Liquid Chromatography/UV Detection with Immunoaffinity Extraction" be adopted AOAC Official First Action status. The method is applicable for the determination of vitamin B12, which includes added cyanocobalamin and natural forms, making it applicable to both fortified and nonfortified products. Vitamin B12 is extracted from the sample in sodium acetate buffer in the presence of sodium cyanide (100 degrees C, 30 min). After purification and concentration with an immunoaffinity column, vitamin B12 is determined by LC with UV detection (361 nm). A single-laboratory validation study was conducted on a range of products, including milk- and soy-based infant formulas, cereals, cocoa beverages, health care products, and polyvitamin premixes. The method demonstrated linear response over a large range of concentrations, recovery rates of 100.8 +/- 7.5% (average +/- SD), repeatability RSD (RSDr) of 2.1%, and intermediate reproducibility (RSD(iR)) of 4.3%. LOD and LOQ values were 0.10 and 0.30 microg/100 g, respectively, and correlation with the reference microbiological assay was good (R2 = 0.9442). The results of the study were published in J. AOAC Int. 91, 786-793 (2008). The performance characteristics of the method met the standard method performance requirements set forth by the Stakeholder Panel on Infant Formula and Adult Nutritionals; thus, the method was determined to be appropriate for First Action status.


Assuntos
Cromatografia Líquida/métodos , Alimentos Formulados/análise , Fórmulas Infantis/química , Vitamina B 12/química , Vitaminas/química , Adulto , Criança , Análise de Alimentos/métodos , Humanos , Lactente , Extração Líquido-Líquido , Padrões de Referência , Reprodutibilidade dos Testes , Raios Ultravioleta
2.
J AOAC Int ; 95(2): 301-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22649910

RESUMO

Vitamin A, a fat-soluble vitamin, is essential for health and plays an important part in vision, bone growth, reproduction, regulating the immune system, cell function, and skin health. Due to the advances in technology and the expansion of its uses, LC technologies are being studied for effectiveness in detecting and quantifying vitamin A in an effort to help determine the amount of vitamin A in various types of samples. For this reason, an Expert Review Panel agreed on June 29, 2011, at the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," to approve "Determination of Vitamin A in Infant Formula and Adult Nutritionals by UPLC-UV" as AOAC Official Method 2011.07. To move from First to Final Action status, it was recommended that additional information be generated for all types of infant formulas and adult nutritional formula matrixes at varied concentration levels, as indicated in the standard method performance requirements. International units or retinol equivalents typically represent the concentration of vitamin A in food and supplements. However, for the purpose of this method, the concentration represented is presented in microg/100 g.


Assuntos
Cromatografia Líquida/métodos , Alimentos Formulados/análise , Fórmulas Infantis/química , Vitamina A/química , Vitaminas/química , Adulto , Criança , Análise de Alimentos/métodos , Humanos , Lactente , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J AOAC Int ; 93(5): 1494-502, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21140662

RESUMO

A fast and simple chromatographic method to determine biotin in foods is presented. Biotin is extracted using papain (60 degrees C, 1 h). After pH adjustment and filtration, biotin is determined by LC with fluorescence detection using postcolumn reagent avidin-FITC (avidin labeled with fluorescein isothiocyanate). The method has been validated in a large range of products: milk- and soy-based infant formulas, cereals, cocoa-malt beverages, and clinical nutrition products. The method showed recovery rates of 98.1 +/- 5.7% (average +/- SD) in a large range of concentrations. Biotin concentrations determined in infant formula standard reference materials 1846 and 1849 were in agreement with reference values. RSD of repeatability (RSDr) varied from 2.0 to 4.5%, and intermediate reproducibility (RSD(iR)) from 5.8 to 9.4%. LOD and LOQ were 3.0 and 5.0 microg/100 g, respectively. The proposed method is suitable for routine analysis of biotin in fortified foods (infant formulas, infant cereals, cocoa-malt beverages, and clinical nutrition products). It can be used as a faster, more selective, and precise alternative to the classical microbiological determination, and is easily transferable among laboratories.


Assuntos
Bebidas/análise , Biotina/análise , Cacau/química , Cromatografia Líquida de Alta Pressão/métodos , Grão Comestível/química , Fórmulas Infantis/química , Fluorescência , Humanos , Lactente , Reprodutibilidade dos Testes
4.
J AOAC Int ; 91(4): 786-93, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18727538

RESUMO

A fast and simple method to determine vitamin B12 in foods is presented. The method allows, in addition to the determination of added cyanocobalamin, the determination of natural vitamin B12 forms, making it also applicable to nonfortified products, especially those that are milk-based. Vitamin B12 is extracted in sodium acetate buffer in the presence of sodium cyanide (100 degrees C, 30 min). After purification and concentration with an immunoaffinity column, vitamin B12 is determined by liquid chromatography with UV detection (361 nm). The method has been validated in analyses of a large range of products: milk- and soy-based infant formulas, cereals, cocoa beverages, health care products, and polyvitamin premixes. The method showed appropriate performance characteristics: linear response over a large range of concentrations, recovery rates of 100.8 +/- 7.5% (average +/- standard deviation), relative standard deviation of repeatability, RSDr, of 2.1%, and intermediate reproducibility, RSDiR, of 4.3%. Limits of detection and quantitation were 0.10 and 0.30 microg/100 g, respectively, and correlation with the reference microbiological assay was good (R2 = 0.9442). The proposed method is suitable for the routine determination of vitamin B12 in fortified foods, as well as in nonfortified dairy products. It can be used as a faster, more selective, and more precise alternative to the classical microbiological determination.


Assuntos
Alimentos Fortificados/análise , Vitamina B 12/análise , Vitaminas/análise , Cromatografia de Afinidade , Cromatografia Líquida de Alta Pressão , Imunoquímica , Indicadores e Reagentes , Padrões de Referência , Reprodutibilidade dos Testes , Solventes , Espectrofotometria Ultravioleta
5.
J AOAC Int ; 88(4): 1008-14, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16152915

RESUMO

An optical biosensor inhibition immunoassay was developed using a specific pantothenic acid-binding protein for the quantitation of free pantothenic acid (vitamin B5) in foodstuffs. Samples were prepared by a simple extraction procedure in buffer, and vitamin content was estimated against authentic calibrants in the same buffer. Performance parameters included a working range of 10-5000 ng/mL, a limit of detection of 4.4 ng/mL, precision relative standard deviation of 5.4-7.1% over a range of concentrations, and recoveries > 95% in the matrixes tested. A wide range of foodstuffs, including National Institute of Standards and Technology reference samples, were tested in 3 independent laboratories and the results were compared with microbiological assay and liquid chromatography/mass spectrometry (LC/MS) methods. The results indicate that the biosensor technique is appropriate for the estimation of pantothenic acid in a wide range of foodstuffs.


Assuntos
Técnicas Biossensoriais/métodos , Suplementos Nutricionais/análise , Imunoensaio/métodos , Ácido Pantotênico/análise , Técnicas Biossensoriais/instrumentação , Calibragem , Cromatografia Líquida/métodos , Relação Dose-Resposta a Droga , Análise de Alimentos , Concentração de Íons de Hidrogênio , Imunoensaio/instrumentação , Fórmulas Infantis/química , Espectrometria de Massas/métodos , Ressonância de Plasmônio de Superfície
6.
J Chromatogr A ; 1032(1-2): 1-6, 2004 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-15065769

RESUMO

Methods for Vitamin B5 determination in food products remain limited by their low sensitivity and poor selectivity. Here, we have developed a liquid chromatography-mass spectrometry (LC-MS) method for Vitamin B5 determination in wide range of fortified food products. Vitamin B5 was extracted from food samples by heat treatment and analysed by LC-MS in the positive mode using electrospray ionisation (ESI). Vitamin B5 was quantified using hopantenic acid (HOPA) as internal standard after their separation on a C18 narrow-bore column with a gradient of mobile phase made of water/acetonitrile and trifluoroacetic acid (TFA) 0.025%. MS with single ion monitoring mode at mass m/z 220 was used for Vitamin B5 quantification. Calibration curve between 0.5 and 10 microg/ml of Vitamin B5 was linear (r2=0.9993) and the detection limit was determined to be 800 pg. The overall quantitative efficiency of the method was evaluated using Nestle reference sample (infant formula). The intra-assay RSD was 4.8% (n=8), the inter-assay RSD 6.4% (n=4) and the recoveries of the spiked samples were above 95%. Application of the LC-MS method to Vitamin B5 determination in wide range of fortified food products including three US National Institute of Standards and Technology (NIST) reference samples (RM 8435, RM 8415 and SRM 1546) shows consistent results with those obtained by microbiology and recoveries of Vitamin B5 between 93 and 104% for the spiked samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Alimentos Fortificados/análise , Ácido Pantotênico/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Calibragem , Padrões de Referência , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta
7.
J Chromatogr A ; 1022(1-2): 115-23, 2004 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-14753777

RESUMO

A novel method for the simultaneous quantification of Vitamins A, D3 and E in fortified infant formulae has been developed using isocratic normal-phase liquid chromatography with positive atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS). Food products were saponified and the vitamins were extracted by solid-phase extraction (SPE) on a Chromabond XTR cartridge. Quantification of Vitamins D3 and E were performed with Vitamin D2 and 5,7-dimethyltocol (DMT) as internal standards (IS), respectively while no IS was used for Vitamin A. Detection of the vitamins was made in the selected ion monitoring (SIM) mode. MS calibration curves were linear between 0.15 and 12 mg/l for Vitamin A, 5-400 microg/l for Vitamin D3 and 0.25-20 mg/l for Vitamin E with regression coefficient r2 > 0.996 and the limits of detection were below 1.4 ng. The repeatability (CV) obtained on a reference dietetic infant formula was 2.3% for Vitamin A, 2.6% for Vitamin E and 5.9% for Vitamin D3. The between-day variations (CV) over 6 days were in the ranges of 2.4-6.9% for the three vitamins. The mean recoveries from a reference infant formula spiked with all three vitamins ranged from 96 to 105% with a relative standard error less than 9%. The applicability of the method was demonstrated by analyzing a set of infant formula and infant cereals; similar results were obtained with the LC-MS method and reference HPLC methods.


Assuntos
Colecalciferol/análise , Alimentos Infantis , Vitamina A/análise , Vitamina E/análise , Humanos , Lactente , Espectrometria de Massas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...