Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 13(6): 7668-79, 2013 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-23771156

RESUMO

A fast and non-destructive voltammetric method to detect cocaine in confiscated samples based on carbon paste electrode modified with methoxy-substituted N,N'-ethylene-bis(salcylideneiminato)uranyl(VI)complexes, [UO2(X-MeOSalen)(H2O)] · H2O, where X corresponds to the positions 3, 4 or 5 of the methoxy group on the aromatic ring, is described. The electrochemical behavior of the modified electrode and the electrochemical detection of cocaine were investigated using cyclic voltammetry. Using 0.1 mol · L(-1) KCl as supporting-electrolyte, a concentration-dependent, well-defined peak current for cocaine at 0.62 V, with an amperometric sensitivity of 6.25 × 104 µA · mol · L(-1) for cocaine concentrations ranging between 1.0 × 10(-7) and 1.3 × 10(-6) mol · L-1 was obtained. Chemical interference studies using lidocaine and procaine were performed. The position of the methoxy group affects the results, with the 3-methoxy derivative being the most sensitive.


Assuntos
Cocaína/análise , Complexos de Coordenação/química , Técnicas Eletroquímicas , Urânio/química , Carbono/química , Eletrodos , Eletrólitos/química , Ciências Forenses , Bases de Schiff/química
2.
Forensic Sci Int ; 221(1-3): 29-32, 2012 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-22525527

RESUMO

A new voltammetric method for the determination of Δ(9)-tetrahydrocannabinol (Δ(9)-THC) is described. The voltammetric experiments were accomplished in N-N dimethylformamide/water (9:1, v/v), using tetrabutylammonium tetrafluoroborate (TBATFB) 0.1mol/L as supporting electrolyte and a glassy carbon disk electrode as the working electrode. The anodic peak current was observed at 0.0V (vs. Ag/AgCl) after a 30s pre-concentration step under an applied potential of -1.2V (vs. Ag/AgCl). A linear dependence of Δ(9)-THC detection was obtained in the concentration range 2.4-11.3ng/mL, with a linear correlation coefficient of 0.999 and a detection limit of 0.34ng/mL. The voltammetric method was used to measure the content of Δ(9)-THC in samples (hemp and hashish) confiscated by the police. The elimination of chemical interferences from the samples was promptly achieved through prior purification using the TLC technique, by employing methanol/water (4:1, v/v) as the mobile phase. The results showed excellent correlation with results attained by HPLC.

3.
Forensic Sci Int ; 192(1-3): 94-7, 2009 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-19720482

RESUMO

In this work, a fast, non destructive voltammetric method for cocaine detection in acetonitrile medium using a platinum disk electrode chemically modified with cobalt-hexacyanoferrate (CoHCFe) film is described. The deposition of CoHCFe film at platinum disk (working electrode) was carried out in aqueous solution containing NaClO(4) at 0.1 mol L(-1) as supporting electrolite. Stability studies of the film and subsequent voltammetric analysis of cocaine were made in acetonitrile medium with NaClO(4) at 0.1 mol L(-1) as supporting electrolite. A reversible interaction between cocaine and CoHCFe at the film produces a proportional decrease of original peak current, due to the formation of a complex between cocaine and cobalt íons, with subsequent partial passivation of the film surface, being the intensity of current decrease used as analytical signal for cocaine. A linear dependence of cocaine detection was carried out in the range from 2.4 x 10(-4) to 1.5 x 10(-3)mol L(-1), with a linear correlation coefficient of 0.994 and a detection limit of 1.4 x 10(-4)mol L(-1). The analysis of confiscated samples by the proposed method indicated cocaine levels from 37% to 95% (m/m) and these results were validated by comparison to HPLC technique, being obtained good correlation between both methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...