Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 13(7)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37511953

RESUMO

The assessment of boron microdistribution is essential to evaluate the suitability of boron neutron capture therapy (BNCT) in different biological models. In our laboratory, we have reported a methodology to produce cell imprints on polycarbonate through UV-C sensitization. The aim of this work is to extend the technique to tissue samples in order to enhance spatial resolution. As tissue structure largely differs from cultured cells, several aspects must be considered. We studied the influence of the parameters involved in the imprint and nuclear track formation, such as neutron fluence, different NTDs, etching and UV-C exposure times, tissue absorbance, thickness, and staining, among others. Samples from different biological models of interest for BNCT were used, exhibiting homogeneous and heterogeneous histology and boron microdistribution. The optimal conditions will depend on the animal model under study and the resolution requirements. Both the imprint sharpness and the fading effect depend on tissue thickness. While 6 h of UV-C was necessary to yield an imprint in CR-39, only 5 min was enough to observe clear imprints on Lexan. The information related to microdistribution of boron obtained with neutron autoradiography is of great relevance when assessing new boron compounds and administration protocols and also contributes to the study of the radiobiology of BNCT.

2.
Appl Radiat Isot ; 165: 109331, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32777741

RESUMO

In Argentina, a multi-institutional project has been established to assess the feasibility of applying BNCT ex-situ to the treatment of patients with multiple metastases in both lungs. Within this context, this work aims at applying the neutron autoradiography technique to study boron microdistribution in the lung. A comprehensive analysis of the different aspects for the generation of autoradiographic images of both normal and metastatic BDIX rat lungs was achieved. Histology, boron uniformity, optimal tissue thickness and water content in tissue were explored for the two types of samples. A qualitative and a quantitative analysis were performed. No heterogeneities in uptake were observed in normal lung. Conversely, samples with metastasis showed preferential boron uptake in the tumour areas with respect to surrounding tissue. Surrounding tissue would present a slightly higher uptake of boron than the normal lung. Quantitative results of boron concentration values and ratios determined by neutron autoradiography were obtained. In order to contribute to BNCT dosimetry, further analysis increasing the number of samples is warranted.


Assuntos
Autorradiografia/métodos , Boro/farmacocinética , Pulmão/metabolismo , Nêutrons , Animais , Terapia por Captura de Nêutron de Boro/métodos , Ratos
3.
Int J Radiat Biol ; 95(5): 646-654, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30601686

RESUMO

PURPOSE: Boron neutron capture therapy (BNCT) combines selective accumulation of 10B carriers in tumor tissue with subsequent neutron irradiation. BNCT has been proposed for the treatment of multiple, non-resectable, diffuse tumors in lung. The aim of the present study was to evaluate the therapeutic efficacy and toxicity of BNCT in an experimental model of lung metastases of colon carcinoma in BDIX rats and perform complementary survival studies. MATERIALS AND METHODS: We evaluated tumor control and toxicity in lung 2 weeks post-BNCT at 2 dose levels, including 5 experimental groups per dose level: T0 (euthanized pre-treatment), Boronophenylalanine-BNCT (BPA-BNCT), BPA + Sodium decahydrodecaborate-BNCT ((BPA + GB-10)-BNCT), Beam only (BO) and Sham (no treatment, same manipulation). Tumor response was assessed employing macroscopic and microscopic end-points. An additional experiment was performed to evaluate survival and oxygen saturation in blood. RESULTS AND CONCLUSIONS: No dose-limiting signs of short/medium-term toxicity were observed in lung. All end-points revealed statistically significant BNCT-induced tumor control vs Sham at both dose levels. The survival experiment showed a statistically significant 45% increase in post-treatment survival time in the BNCT group (48 days) versus Sham (33 days). These data consistently revealed growth suppression of lung metastases by BNCT with no manifest lung toxicity. Highlights Boron Neutron Capture Therapy suppresses growth of experimental lung metastases No BNCT-induced short/medium-term toxicity in lung is associated with tumor control Boron Neutron Capture Therapy increased post-treatment survival time by 45.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Pulmonares/radioterapia , Pesquisa Translacional Biomédica , Animais , Terapia por Captura de Nêutron de Boro/efeitos adversos , Linhagem Celular Tumoral , Neoplasias do Colo/secundário , Relação Dose-Resposta à Radiação , Neoplasias Pulmonares/patologia , Radiometria , Ratos , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...