Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 12(8): 985-9, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11487680

RESUMO

PURPOSE: To compare, with use of intravascular ultrasound (IVUS) as an internal reference standard in a porcine model, arterial diameters measured from arteriograms obtained with use of CO(2) to those obtained with use of iodinated contrast material (ICM). MATERIALS AND METHODS: In nine pigs, digital subtraction angiograms (DSAs) were obtained in the aorta and iliac arteries to compare vessel diameters measured with use of CO(2) to those measured with use of ICM. These measurements were divided by measurements made with use of intravascular ultrasound (IVUS) to yield a DSA/IVUS ratio. Differences between ICM and CO(2) were compared with analysis of variance to assess the effect of location (aorta vs iliac), contrast material used (ICM vs CO(2)), and position (posteroanterior, right anterior oblique, or left anterior oblique). Secondary analysis compared measurements of dependent and nondependent iliac arteries and compared the use of hand-injected CO(2) to that of CO(2) injected by an injector. RESULTS: The DSA/IVUS ratio was 70.7% +/- 4.4% with ICM use and 69.6% +/- 6.3% with CO(2) use, which did not represent a significant difference (P =.311). Animal position had no effect (P =.477). Underestimation was worse in the iliac arteries than in the aorta (67.4% +/- 1.5% vs 71.4% +/- 1.7%; P =.038). There was no difference in nondependent (P =.163) arteries, but CO(2) underestimated dependent iliac artery size more than ICM did (66.3% +/- 4.8% vs 70.3% +/- 5.4%; P =.051). Vessel diameter was underestimated more with the CO(2) injector than with hand-injected CO(2) (64.3% +/- 2.3% vs 71.7% +/- 1.7%; P <.0001). CONCLUSION: There is no difference in diameter underestimation between CO(2) and ICM in this animal model. Hand-injection of CO(2) causes less underestimation of vessel diameter than does the CO(2) injector.


Assuntos
Angiografia/métodos , Aorta Abdominal/ultraestrutura , Dióxido de Carbono , Meios de Contraste , Artéria Ilíaca/diagnóstico por imagem , Iodo , Animais , Aorta Abdominal/diagnóstico por imagem , Cobaias , Modelos Animais , Ultrassonografia
2.
Postgrad Med ; 61(5): 149-54, 1977 May.
Artigo em Inglês | MEDLINE | ID: mdl-193094

RESUMO

Hematologic complications of alcoholism are common. Folic acid deficiency can lead to pancytopenia. Iron-deficiency anemia, various hemolytic states, and abnormalities in both function and number of platelets can occur. There is a great deal of interest in the adverse effects of alcohol on pyridoxine (vitamin B6) and folic acid metabolism. Malignant disease often complicates alcoholism and should always be suspected.


Assuntos
Alcoolismo/complicações , Doenças Hematológicas/etiologia , Neoplasias/etiologia , Alcoolismo/terapia , Anemia Hipocrômica/etiologia , Anemia Sideroblástica/etiologia , Transtornos Plaquetários/etiologia , Carcinoma Hepatocelular/etiologia , Neoplasias Esofágicas/etiologia , Deficiência de Ácido Fólico/etiologia , Granulócitos , Humanos , Neoplasias Laríngeas/etiologia , Leucopenia/etiologia , Neoplasias Hepáticas/etiologia , Neoplasias Bucais/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...