Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Sci Total Environ ; 727: 138618, 2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32498211

RESUMO

Combined sewer overflows (CSOs) are a major source of surface water pollution and degradation. This is particularly visible where sewage collection with combined sewer and centralized treatment are well established, such as in Europe and North America: an overwhelming number of surface water bodies are in insufficient status of ecology, hydrology and physico-chemical parameters. Therefore, several countries have started implementing constructed wetlands (CWs) as mainstream on-spot treatment. This paper summarizes the main design approaches that can be adopted. We identified eight different schemes for the implementation of CSO-CWs, based on our international experience and documented by a literature analysis. The performance review includes conventional water quality parameters, as well as pathogen and emergent contaminant removal. Furthermore, modelling tools for advanced design and for understanding a wide applicability of these green infrastructures are presented. This paper also provides a review on other side benefits offered by the adoption of Nature-Based Solutions for CSO treatment, such as ecosystem services, and the most common issues related to their operation and maintenance. Our analysis has produced a list of key factors for design and operation, all derived from full-scale installations in operation up to more than ten years.

3.
Water Sci Technol ; 75(11-12): 2586-2597, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28617278

RESUMO

The performance of a vertical flow constructed wetland for combined sewer overflow treatment (CSO CW) has been evaluated. The full-scale site has been monitored for 3 years for major pollutants and for two load events for a range of micropollutants (metals, metalloids and polycyclic aromatic hydrocarbons (PAHs)). Performance were predominantly high (97% for total suspended solids (TSS), 80% for chemical oxygen demand (COD), 72% for NH4-N), even if several loads were extremely voluminous, pushing the filter to its limits. Two different filter materials (a 4:1 mixture of sand and zeolite and natural pozzolana) showed similar treatment performance. Furthermore, environmental factors were correlated with COD removal efficiency. The greatest influencers of COD removal efficiency were the inlet dissolved COD concentrations and the duration and potential evapotranspiration during inter-event periods. Furthermore, sludge was analysed for quality and a sludge depth map was created. The map, and calculating the changes in sludge volume, helped to understand solid accumulation dynamics.


Assuntos
Esgotos/análise , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/análise , Áreas Alagadas , Análise da Demanda Biológica de Oxigênio , França , Eliminação de Resíduos Líquidos/instrumentação
5.
Water Sci Technol ; 71(9): 1333-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25945849

RESUMO

Approximately 3,500 constructed wetlands (CWs) provide raw wastewater treatment in France for small communities (<5,000 people equivalent). Built during the past 30 years, most consist of two vertical flow constructed wetlands (VFCWs) in series (stages). Many configurations exist, with systems associated with horizontal flow filters or waste stabilization ponds, vertical flow with recirculation, partially saturated systems, etc. A database analyzed 10 years earlier on the classical French system summarized the global performances data. This paper provides a similar analysis of performance data from 415 full-scale two-stage VFCWs from an improved database expanded by monitoring data available from Irstea and the French technical department. Trends presented in the first study are confirmed, exhibiting high chemical oxygen demand (COD), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN) removal rates (87%, 93% and 84%, respectively). Typical concentrations at the second-stage outlet are 74 mgCOD L(-1), 17 mgTSS L(-1) and 11 mgTKN L(-1). Pollutant removal performances are summarized in relation to the loads applied at the first treatment stage. While COD and TSS removal rates remain stable over the range of applied loads, the spreading of TKN removal rates increases as applied loads increase.


Assuntos
Purificação da Água/estatística & dados numéricos , Áreas Alagadas , Análise da Demanda Biológica de Oxigênio , França , Nitrogênio/análise , Lagoas , Águas Residuárias/análise
6.
Water Sci Technol ; 71(8): 1113-27, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25909720

RESUMO

The application of wetland systems for the treatment of wineries wastewater started in the early 1990s in the USA followed a few years later by France, Italy, Germany and Spain. Various studies demonstrated the efficiency of constructed wetlands (CWs) as a low cost, low maintenance and energy-saving technology for the treatment of wineries wastewater. Several of these experiences have also shown lessons to be learnt, such as some limits in the tolerance of the horizontal subsurface flow and vertical subsurface flow classic CWs to the strength of the wineries wastewater, especially in the first stage for the multistage systems. This paper is presenting an overview of all the reported experiences at worldwide level during the last 15 years, giving particular attention and provision of details to those systems that have proven to get reliable and constant performances in the long-term period and that have been designed and realized as optimized solutions for the application of CW technology to this particular kind of wastewater. The organic loading rates (OLRs) applied to the examined 13 CW systems ranged from about 30 up to about 5,000 gCOD/m² d (COD: chemical oxygen demand), with the 80th percentile of the reported values being below 297 gCOD/m² d and the median at 164 gCOD/m² d; the highest OLR values have in all cases been measured during the peak season (vintage) and often have been linked to lower surface removal rates (SRRs) in comparison to the other periods of the year. With such OLRs the SRRs have ranged from a minimum of 15 up to 4,700 gCOD/m² d, with the 80th percentile of the reported values being below 308 gCOD/m² d and the median at 112 gCOD/m² d.


Assuntos
Indústria Alimentícia , Resíduos Industriais , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química , Áreas Alagadas , Análise da Demanda Biológica de Oxigênio
7.
Water Sci Technol ; 60(5): 1145-54, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19717900

RESUMO

Sludge drying reed beds have been used for dewatering and mineralization of sludge since the beginning of the 90s, but their insufficient performances in terms of Dry Matter [DM] content and mineralization of the sludge have made necessary new studies. Therefore, 8 pilots of 2 m2 each and a full-scale plant (13,000 p.e, 8 beds of 470 m2 in operation for 4 years) have been monitored to examine the influence of the sludge loading rate, the sludge quality and the loading frequency on the dewatering and mineralization efficiencies. Two filtration layers and two loading rhythms were tested on pilots which were fed at a loading rate of 25-30 kg DM m(-2) yr(-1) during the first year of operation (commissioning period). Hydraulic behaviour (infiltration rate, outflow), O2 and CO2 relative concentrations in the filtration media, redox potential, pollutants removal and dry matter content were assessed during all the study. The rheological quality of the extracted sludge from full scale beds was assessed and showed that its mechanical behaviour exceed those of sludge of comparable dry matter content, making its spreading easier. Therefore, this sludge could easily claim the status of solid and stabilized sludge according to the French regulation. Design and management recommendations (number of beds, loading rates, feeding/rest period) gained from the experiments results are suggested.


Assuntos
Poaceae/metabolismo , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Biodegradação Ambiental , Estudos de Viabilidade , Fenômenos Mecânicos , Projetos Piloto , Poaceae/crescimento & desenvolvimento , Reologia , Solo
8.
Water Sci Technol ; 60(3): 643-53, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19657159

RESUMO

French legislation requires the control of private on-site sanitation systems by local authorities. This will result in a large increase of the quantity of sludge from septic tanks to be treated. Nevertheless, large wastewater treatment plants are not systematically able to treat this sludge because they may have reached their nominal load or they are not so numerous in rural zone to avoid too long transportation. The study concerns both the feasibility of sludge reed beds devoted to the treatment of septage and the assessment of a simultaneous treatment with aerated sludge. The experiments have been carried out on eight pilot-scale drying reed beds (2 m(2)) planted with Phragmites australis. Two filtration layers of either vegetal compost or sand were tested. The study is focused on the commissioning period (first vegetative year) with a loading rate of 30 kg SS m(-2) yr(-1). According to these operational conditions, dewatering efficiencies reached approx. 30% DM during summer but less than 20% DM in winter for each filtration layer and sludge. High removal efficiencies, with an average of 96%, 92% and 89% for SS, COD and TKN respectively, were achieved with septage whereas they were lower for the mixture of aerated sludge and septage. The dewaterability of septage and its filtration behaviour were assessed by several parameters (Capillary Suction Time, bound water) which may be some interesting tools for an optimised loading strategy.


Assuntos
Poaceae/metabolismo , Esgotos/química , Aerobiose , Biodegradação Ambiental , Filtração , Substâncias Húmicas/análise , Oxirredução , Tamanho da Partícula , Projetos Piloto , Poaceae/crescimento & desenvolvimento , Eliminação de Resíduos Líquidos , Poluentes Químicos da Água/isolamento & purificação
9.
Water Sci Technol ; 56(3): 23-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17802834

RESUMO

The effect of organic loading, season and plant species on the treatment of fish farm effluent was tested using three-year old mesocosm wetland systems. During one year, nine 1 m2 mesocosms (horizontal subsurface flow), located in a controlled greenhouse environment, were fed with a reconstituted fish farm effluent containing a high fraction of soluble components (1,600 microS/cm and in mg/L: 230 +/- 80 COD, 179 +/- 60 sCOD, 100 +/- 40 TSS, 37 +/- 7 TKN, 14 +/- 2 TP). Combinations of three hydraulic loading rates (30, 60 and 90 L.m(-2) d(-1)) and two plant species (Phragmites australis, Typha angustifolia) and an unplanted control were tested for treatment performance and hydraulic behaviour. Loadings higher than 15 g COD m(-2) d(-1) resulted in a net decrease of hydraulic performances (generation of short circuiting) coupled with low TKN removal. Maximal TKN removal rates (summer: 1.2, winter: 0.6 g.m(-2) d(-1)) were reached in planted units. In all mesocosms, phosphorus was removed during summer (maximal removal rate: 0.3 g TP m(-2) d(-1)) and was released in winter (release rate = approximately half of summer removal rate). This study confirmed that constructed wetlands are susceptible to clogging when treating anaerobic storage tank supernatant rich in highly biodegradable compounds. Contributions of plants to hydraulic efficiency were mainly observed in summer, associated with high evapotranspiration rates. Both plant species gave a similar removal efficiency for all pollutants.


Assuntos
Anaerobiose , Eliminação de Resíduos Líquidos/métodos , Eliminação de Resíduos Líquidos/normas , Áreas Alagadas , Animais , Animais Domésticos , Peixes , Cinética , Fósforo , Plantas , Estações do Ano , Typhaceae , Eliminação de Resíduos Líquidos/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...