Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Brain Stimul ; 14(3): 635-642, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33785406

RESUMO

BACKGROUND: Post-traumatic Stress Disorder (PTSD) often does not respond to available treatments. Memories are vulnerable to disruption during reconsolidation, and electroconvulsive therapy (ECT) has amnestic effects OBJECTIVE/HYPOTHESIS: To test the use of ECT to disrupt the reconsolidation of traumatic memories as a potential treatment for PTSD METHODS: Participants were adults from the civilian population and were referred for ECT treatment for severe depression with comorbid PTSD symptoms. Twenty-eight participants were randomly assigned to reactivation of a traumatic or non-traumatic memory using audio script driven imagery prior to each ECT treatment. Primary outcomes were change in scores on the Modified PTSD Symptom Scale - Self Report (MPSS-SR) and the Clinician-Administered PTSD Scale for DSM-5 (CAPS-5). Secondary outcomes included a comparison of the change in heart rate while listening to the script RESULTS: Twenty-five female patients who completed a post-ECT assessment were included in the analysis. No significant group differences were found in the MPSS-SR or CAPS-5 scores from pre-ECT to post-ECT or 3-month follow-ups. However, both groups improved at post-ECT and 3-month follow up. Partial eta squared estimates of effect size showed large effect sizes for all outcomes (η2 > 0.13). Changes in heart rate were not significantly different between groups or over time CONCLUSIONS: ECT paired with pre-treatment traumatic memory reactivation was not more effective for treating PTSD symptoms than ECT with non-traumatic memory reactivation. While our primary hypothesis was not supported, our data provides further support for the efficacy of ECT for improving symptoms of PTSD with comorbid depression. ClinicalTrials.gov. https://clinicaltrials.gov/ct2/show/NCT04027452. IDENTIFIER: NCT04027452.


Assuntos
Eletroconvulsoterapia , Transtornos de Estresse Pós-Traumáticos , Adulto , Feminino , Frequência Cardíaca , Humanos , Transtornos de Estresse Pós-Traumáticos/terapia , Tempo , Resultado do Tratamento
2.
Behav Brain Res ; 381: 112420, 2020 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-31821787

RESUMO

Neuronal calcium sensor-1 or Frequenin is a calcium sensor widely expressed in the nervous system, with roles in neurotransmission, neurite outgrowth, synaptic plasticity, learning, and motivated behaviours. Neuronal calcium sensor-1 has been implicated in neuropsychiatric disorders including autism spectrum disorder, schizophrenia, and bipolar disorder. However, the role of neuronal calcium sensor-1 in behavioural phenotypes and brain changes relevant to autism spectrum disorder have not been evaluated. We show that neuronal calcium sensor-1 deletion in the mouse leads to a mild deficit in social approach and impaired displaced object recognition without affecting social interactions, behavioural flexibility, spatial reference memory, anxiety-like behaviour, or sensorimotor gating. Morphologically, neuronal calcium sensor-1 deletion leads to increased dendritic arbour complexity in the frontal cortex. At the level of hippocampal synaptic plasticity, neuronal calcium sensor-1 deletion leads to a reduction in long-term potentiation in the dentate gyrus, but not area Cornu Ammonis 1. Metabotropic glutamate receptor-induced long-term depression was unaffected in both dentate and Cornu Ammonis 1. These studies identify roles for neuronal calcium sensor-1 in specific subregions of the brain including a phenotype relevant to neuropsychiatric disorders.


Assuntos
Comportamento de Escolha/fisiologia , Cognição/fisiologia , Potenciação de Longa Duração/genética , Proteínas Sensoras de Cálcio Neuronal/genética , Plasticidade Neuronal/genética , Neuropeptídeos/genética , Reconhecimento Psicológico/fisiologia , Animais , Ansiedade/genética , Região CA1 Hipocampal/fisiologia , Giro Denteado/fisiopatologia , Lobo Frontal/patologia , Camundongos , Camundongos Knockout , Receptores de Glutamato Metabotrópico , Filtro Sensorial/genética , Comportamento Social , Interação Social , Memória Espacial/fisiologia
3.
J Neurosci Methods ; 294: 81-90, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29126813

RESUMO

BACKGROUND: There have been inconsistencies in the histological abnormalities found in the cerebral cortex from patients with schizophrenia, bipolar disorder and major depression. Discrepancies in previously published reports may arise from small sample sizes, inconsistent methodology and biased cell counting. METHODS: We applied automated quantification of neuron density, neuron size and cortical layer thickness in large regions of the cerebral cortex in psychiatric patients. This method accurately segments DAPI positive cells that are also stained with CUX2 and FEZF2. Cortical layer thickness, neuron density and neuron size were automatically computed for each cortical layer in numerous Brodmann areas. RESULTS: We did not find pronounced cytoarchitectural abnormalities in the anterior cingulate cortex or orbitofrontal cortex in patients with schizophrenia, bipolar disorder or major depressive disorder. There were no significant differences in layer thickness measured in immunohistochemically stained slides compared with traditional Nissl stained slides. Automated cell counts were correlated, reliable and consistent with manual counts, while being much less time-consuming. CONCLUSION: We demonstrate the validity of using a novel automated analysis approach to post-mortem brain tissue. We were able to analyze large cortical areas and quantify specific cell populations using immunohistochemical markers. Future analyses could benefit from efficient automated analysis.


Assuntos
Giro do Cíngulo/patologia , Imuno-Histoquímica/métodos , Transtornos Mentais/patologia , Neurônios/patologia , Córtex Pré-Frontal/patologia , Adulto , Idoso , Algoritmos , Contagem de Células , Feminino , Giro do Cíngulo/metabolismo , Proteínas de Homeodomínio/metabolismo , Humanos , Masculino , Transtornos Mentais/metabolismo , Pessoa de Meia-Idade , Neurônios/metabolismo , Córtex Pré-Frontal/metabolismo , Reprodutibilidade dos Testes , Fatores de Transcrição/metabolismo
4.
J Cardiovasc Electrophysiol ; 28(3): 273-279, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27933666

RESUMO

INTRODUCTION: Because of the unclear prognostic effects of ablation of atrial fibrillation (AF), oral anticoagulation (OAC) is often continued after ablation even in asymptomatic patients. We sought to determine the frequency of stroke and AF recurrence in patients on and off therapeutic OAC 1 year after a successful AF ablation. METHODS AND RESULTS: Patients that underwent AF ablation and were free of AF 12 months after ablation were selected from our AF database. During follow-up (FU), patients were screened for recurrence of AF, changes in OAC or antiarrhythmic medication, and the occurrence of stroke or transient ischemic attack (TIA). A total of 398 patients (median age 60.7 years [50.8, 66.8], 25% female) were investigated. The median duration of FU was 529 (373, 111,3.5) days. OAC was discontinued in 276 patients (69.3%). During FU, 4 patients (1%) suffered from stroke and 55 patients (13.8%) experienced a recurrence of AF. Persistent AF was significantly associated with a greater chance of AF recurrence (49.1% vs. 26.8%; P = 0.001). Neither CHADS2 nor CHA2DS2-VASc-Score nor recurrence of AF were significantly different in patients with or without stroke. There was a trend toward a higher percentage of coronary artery disease among patients that experienced stroke (50% vs. 10%; P = 0.057). CONCLUSION: The overall risk of stroke and AF recurrence is low in patients with a recurrence free interval of at least 12 months after AF ablation. Of note, recurrence of AF was not associated with a higher risk of stroke in our study population.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ataque Isquêmico Transitório/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Doença da Artéria Coronariana/complicações , Bases de Dados Factuais , Intervalo Livre de Doença , Esquema de Medicação , Feminino , Humanos , Incidência , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
5.
Can J Cardiol ; 32(11): 1348-1354, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27118059

RESUMO

BACKGROUND: Success rates of atrial fibrillation (AF) ablation have been shown to be significantly lower for patients with persistent AF. However, little is known about the risk factors predicting progression to persistent AF in patients awaiting AF ablation. METHODS: We performed a retrospective, single-centre investigation of patients with paroxysmal AF at the time of placement on the ablation waiting list. Patients were defined as having progressed if they had developed self-reported or electrocardiogram-recorded AF durations more than 7 days while awaiting ablation. After ablation, clinical visits at 3, 6, 9, 12, and 18 months were performed with a minimum of a 48-hour-Holter and electrocardiogram. Baseline characteristics including left atrial diameter (LA) and the HATCH score were analyzed by univariable and multivariable analysis for predicting progression to persistent AF. RESULTS: During a median waiting time of 9.7 (6.1, 14.2) months, 60 of 564 patients (11%) progressed to persistent AF. In patients who progressed, ablation took longer (180 [150, 249] minutes vs 157 [125, 210] minutes; P = 0.009) and was associated with a higher rate of recurrence after a median of 12 months (53.3% vs 39.1%; P < 0.001). The HATCH score was a poor predictor of AF progression (area under the curve 0.54), whereas an LA diameter of more than 45 mm (odds ratio 3.46, P < 0.001) and heart failure (odds ratio 3.11, P = 0.036) were strong and independent predictors of AF progression in multivariable analysis. CONCLUSIONS: Patients with an increased LA diameter or heart failure have a significantly increased risk of progression to persistent AF. These characteristics may define patients who should undergo earlier catheter ablation to optimize outcome.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Progressão da Doença , Feminino , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Duração da Cirurgia , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Medição de Risco
6.
Can J Cardiol ; 30(12): 1541-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25475459

RESUMO

BACKGROUND: There is a paucity of data that compare traditional vitamin K antagonist (VKA) with novel oral anticoagulant regimens in periprocedural management of cardioversion or ablation of atrial fibrillation (AF). We sought to compare outcomes of use of VKA, dabigatran (DABI), and rivaroxaban (RIVA) anticoagulation around the time of intervention. METHODS: We studied consecutive patients undergoing cardioversion or ablation of AF at our centre from October 2010 to October 2013. There were 3 different anticoagulation groups: warfarin (VKA), DABI, and RIVA. Safety was assessed according to number of strokes, transient ischemic attacks (TIAs), and clinically important and not important bleeding events. RESULTS: Baseline characteristics were well balanced between the groups. Average follow-up was 6 months (± 4 months). A total of 901 patients who underwent cardioversion were studied (VKA [n = 471], DABI [n = 288] and RIVA [n = 141]). In these patients there were no strokes seen during follow-up and 2 TIAs in the DABI group. Bleeding rates were low, with no significant difference between the 3 groups. A total of 680 patients who underwent ablation were studied (VKA [n = 319], DABI [n = 220] and RIVA [n = 171]). There were no strokes reported during follow-up and 3 TIAs: 2 in the VKA group and 1 in the DABI group not resulting in a significant difference between the groups. Bleeding rates were low, with no significant difference between the groups. CONCLUSIONS: Overall, there was a low incidence of adverse events for all anticoagulation regimens. Warfarin, DABI, and RIVA use around the time of the procedure are safe and reasonable options for patients who undergo cardioversion or AF ablation.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Cardioversão Elétrica/métodos , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...