Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37787629

RESUMO

X-ray diagnostics are key instruments for understanding the physics behind inertial confinement fusion experiments. We report on the multilayer design optimization for the Toroidal X-ray Imager (TXI), a hard x-rays microscope instrument designed by Commissariat à l'énergie atomique (CEA) and Laboratoire Charles Fabry (LCF) to be installed on the National Ignition Facility. TXI includes six channels designed for three different energy bands centered on 8.7, 13, and 17.5 keV. Each channel is made up of two toroidal mirrors arranged in a Wolter-like configuration. The required field of view is 800 × 400 µm2, and the resolution should be better than 5 µm. In addition, we seek to estimate the spatial distribution of the temperature, which requires no spectral overlap of the different energy bands and a good spectral homogeneity of the image produced. The development of the multilayer coatings was performed in a two-step method. First, the coatings were optimized to obtain proper energy bands. Then, an x-ray tracing code was used to calculate the integrated optical response of each channel and adjust the response of the mirror to fulfill the requirements. To fulfill all the specifications, we propose an original design using a combination of two aperiodic coatings, one with a narrow bandwidth and the other one with a larger bandwidth.

2.
Rev Sci Instrum ; 93(11): 113502, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461505

RESUMO

During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100-200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel-ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2-4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2-4 keV spectral power with an uncertainty of ±8.7%.

3.
Rev Sci Instrum ; 89(11): 113702, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501355

RESUMO

High-resolution, high-sensitivity X-ray imaging is a real challenge in high-energy density plasma experiments. We present an improved design of the Fresnel ultra high-resolution imager instrument. Using an Ultra-High-Intensity (UHI) laser to generate hot and dense plasma in a small volume of an Al-Ti mixed target provides simultaneous imaging of both Al and Ti X-ray emission. Specifically, the Al Heß (or Lyß) and the Ti Heα lines are imaged with a resolution of (2.7 ± 0.3) µm and (5.5 ± 0.3) µm, respectively. It features two transmission Fresnel phase zone plates fabricated on the same substrate, each associated with a multilayer mirror for spectral selection. Their spatial resolution has been measured on the PTB synchrotron radiation facility laboratory at BESSY II and on the EQUINOX laser facility. Results obtained on an UHI experiment highlight the difference of emission zone sizes between Al and Ti lines and the versatility of this instrument.

4.
Rev Sci Instrum ; 88(1): 013701, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147634

RESUMO

High-resolution, high-sensitivity X-ray imaging is a real challenge in laser plasma diagnostic to attain reliable data in high-energy density plasma experiments. In this context, ultra-high-intensity lasers generate hot and dense plasma but only in a small volume. An experiment has been performed at the LULI2000 laser facility to diagnose such plasma conditions from thermal spectroscopic data. To image the emission zone plasma's Al Heß, a Fresnel-lens-based X-ray imager has been developed. It features a 846 µm-diameter Fresnel Phase Zone Plate (FPZP) and a Pd/B4C multilayer mirror (thickness d = 5.1 nm). This association can be used between 1500 eV and 2100 eV. The FPZP's efficiency was measured on a synchrotron facility (SOLEIL) and its spatial resolution in a laser facility (EQUINOX). The mirror reflectivity was measured on the synchrotron facility BESSY II. With experimental conditions, the system resolution reaches 3.8 ± 0.6 µm with an adequate efficiency in the 1800 eV-1900 eV energy range with a solid angle of 9 × 10-6 sr. Consequently, a FPZP is an excellent optics setup for high-resolution quasi-monochromatic X-ray imaging and provides a good collection angle. Bragg-Fresnel lenses, based on the principle of FPZP and mirrors, are currently designed for an X-ray imager at the Laser MégaJoule facility.

5.
Opt Express ; 22(21): 25853-65, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25401618

RESUMO

We present an experimental study and performance improvement of periodic and aperiodic Ni/SiC multilayer coatings. Periodic Ni/SiC multilayer mirrors have been coated and characterized by grazing incidence X-ray reflectometry at 8.048 keV (Cu Kα radiation) and by measurements at 3 keV and 5 keV on synchrotron radiation facilities. An interdiffusion effect is found between Ni and SiC layers. A two-material model, Ni(x)Si(y)/SiC, using a silicide instead of Ni, was used to fit the measurements. The addition of 0.6 nm W barrier layers at the interfaces allows a significant reduction of the interdiffusion between Ni and SiC. In order to obtain a specific reflectivity profile in the 2 - 8 keV energy range, we have designed and coated aperiodic multilayer mirrors by using Ni/SiC with and without W barrier layers. The experimental reflectivity profiles as a function of the photon energy were measured on a synchrotron radiation facility in both cases. Adding W barrier layers in Ni/SiC multilayers provides a better precision on the layer thicknesses and a very good agreement between the experimental data and the targeted spectral profile.


Assuntos
Compostos Inorgânicos de Carbono/química , Níquel/química , Fenômenos Ópticos , Compostos de Silício/química , Tungstênio/química , Modelos Teóricos , Raios X
6.
Rev Sci Instrum ; 85(1): 013503, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24517761

RESUMO

CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV < photon energy < 5 keV) use only a filter and a coaxial detector. A further improvement of DMX consists in flat-response X-ray channels for a precise absolute measurement of the photon flux in the photon energy range from 0.1 keV to 6 keV. Such channels are equipped with a filter, a Multilayer Mirror (MLM), and a coaxial detector. We present as an example the development of channel for the gold M emission lines in the photon energy range from 2 keV to 4 keV which has been successfully used on the OMEGA laser facility. The results of the radiant power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

7.
Rev Sci Instrum ; 83(10): 10E533, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127039

RESUMO

Multilayer mirrors with enhanced bandwidth were developed with special performances for dense plasma diagnostics and mainly for high spatial resolution x-ray imaging. The multilayer coatings are designed to provide broadband x-ray reflectance at low grazing incidence angles. They are deposited onto toroidal mirror substrates. Our research is directed at the development of non-periodic (depth graded) W∕Si multilayer specifically designed for use in the 1 to 30 keV photon energy band. First, we present a study for a 5 to 22 keV x-ray spectral window at 0.45° grazing angle. The goal is to obtain a high and constant reflectivity. Second, we have modeled a broadband mirror coating for harder x-rays in the range from 10 to 30 keV, with a non-periodic structure containing 300 W∕SiC layers with periods in the range from 0.8 to 4 nm, designed for 0.35° grazing incidence angle.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...