Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113512, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461481

RESUMO

Dedicated nuclear diagnostics have been designed, developed, and built within EUROFUSION enhancement programs in the last ten years for installation at the Joint European Torus and capable of operation in high power Deuterium-Tritium (DT) plasmas. The recent DT Experiment campaign, called DTE2, has been successfully carried out in the second half of 2021 and provides a unique opportunity to evaluate the performance of the new nuclear diagnostics and for an understanding of their behavior in the record high 14 MeV neutron yields (up to 4.7 × 1018 n/s) and total number of neutrons (up to 2 × 1019 n) achieved on a tokamak. In this work, we will focus on the 14 MeV high resolution neutron spectrometers based on artificial diamonds which, for the first time, have extensively been used to measure 14 MeV DT neutron spectra with unprecedented energy resolution (Full Width at Half Maximum of ≈1% at 14 MeV). The work will describe their long-term stability and operation over the DTE2 campaign as well as their performance as neutron spectrometers in terms of achieved energy resolution and high rate capability. This important experience will be used to outline the concept of a spectroscopic neutron camera for the SPARC tokamak. The proposed neutron camera will be the first one to feature the dual capability to measure (i) the 2.5 and 14 MeV neutron emissivity profile via the conventional neutron detectors based on liquid or plastics scintillators and (ii) the 14 MeV neutron spectral emission via the use of high-resolution diamond-based spectrometers. The new opportunities opened by the spectroscopic neutron camera to measure plasma parameters will be discussed.

2.
Nanotechnology ; 32(2): 024002, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-32957094

RESUMO

Thermal and concentrated solar solid-state converters are devices with no moving parts, corresponding to long lifetimes, limited necessity of maintenance, and scalability. Among the solid-state converters, the thermionic-based devices are attracting an increasing interest in the specific growing sector of energy conversion performed at high-temperature. During the last 10 years, hybrid thermionic-based concepts, conceived to cover operating temperatures up to 2000 °C, have been intensively developed. In this review, the thermionic-thermoelectric, photon-enhanced thermionic emission, thermionic-photovoltaic energy converters are extensively discussed. The design and development processes as well as the tailoring of the properties of nanostructured materials performed by the authors are comprehensively described and compared with the advances achieved by the international scientific community.

3.
J Nanosci Nanotechnol ; 17(3): 1564-570, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-29693353

RESUMO

Zinc antimonide (ZnSb) is a promising thermoelectric material for the temperature range 300­ 600 K. ZnSb thin films were prepared by nanosecond Pulsed Laser Deposition (PLD) to evaluate the performance of nanostructured films for thermoelectric conversion by the determination of the Power Factor. A study of the influence of structural, compositional and thermoelectric properties of thin films is reported as a function of different deposition parameters, such as repetition rate, pulse energy, and substrate temperature. The evaluation of a thin film ZnSb compound with excess Sb has been performed to verify the variation of the thermoelectric properties. The obtained results are reported and discussed in the 300­600 K temperature range.

4.
Rev Sci Instrum ; 87(11): 11D833, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910565

RESUMO

A prototype Single crystal Diamond Detector (SDD) was installed at the Joint European Torus (JET) in 2013 along an oblique line of sight and demonstrated the possibility to carry out neutron spectroscopy measurements with good energy resolution and detector stability in discharges heated by neutral beam injection and radio-frequency waves. Starting from these positive results, within the Vertical Neutron Spectrometer project of the Joint European Torus, we have developed a pixelated instrument consisting of a matrix of 12 independent SDDs, called the Diamond Vertical Neutron Spectrometer (DVNS), which boosts the detection efficiency of a single SDD by an order of magnitude. In this paper we describe the main features of the DVNS, including the detector design, energy resolution, and data acquisition system for on-line processing. Preliminary spectroscopy measurements of 2.5 MeV neutrons from the present deuterium plasma at JET are finally presented.

5.
Rev Sci Instrum ; 85(11): 11E101, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430280

RESUMO

Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (<30 ns), which are essential to enable high counting rate (>1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the (12)C(n, α)(9)Be reaction occurring between neutrons and (12)C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.

6.
Phys Med ; 24(3): 159-68, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18468930

RESUMO

New solid-state detectors, based on chemical vapour deposited (CVD) polycrystalline diamonds produced by hot-filament (HF) or microwave plasma (MW) assisted deposition methods, were constructed for radiation therapy dosimetry. Properties of diamond crystals, such as high radiation sensitivity, resistance to radiation damage and tissue-equivalence giving a low-energy dependence are very advantageous for clinical dosimetry. Therefore the encapsulation was specially designed for these detectors to have as little influence as possible on the radiation response. The prototypes were irradiated with use of a wide range of photon beam qualities ((60)Co gamma-rays, 6 and 18 MV X-rays). The radiation sensitivity varied considerably between samples deposited with HF (9 nC Gy(-1)mm(-3)) and MW (66 and 144 nC Gy(-1)mm(-3)) methods. For all detectors the leakage current was of the order of 10% of the radiation-induced current (bias voltage 100 V, dose rate 0.3 Gy/min). When irradiated with (60)Co gamma-rays, the detectors showed a dose-rate linearity with an exponential Delta parameter close to unity. However, a difference of 8% was found between Delta values for the different beam qualities. A small energy dependence was observed, for which the most probable sources are interface effects due to the silver electrodes and partly the geometry of the encapsulation which needs to be further optimized. Despite some limitations in the performance of present prototype detectors, with an improved CVD technique producing crystals of better electrical and dosimetric properties, and with a well-designed tissue-equivalent encapsulation, CVD-diamonds could serve as very good dosimeters for radiotherapy.


Assuntos
Diamante , Fótons , Radiometria/métodos , Doses de Radiação , Fatores de Tempo , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...