Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Urol ; 192(6): 1756-61, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25014577

RESUMO

PURPOSE: Although long-term outcomes after initial placement of artificial urinary sphincters are established, limited data exist comparing sphincter survival in patients with compromised urethras (prior radiation, artificial urinary sphincter placement or urethroplasty). We evaluated artificial urinary sphincter failure in patients with compromised and noncompromised urethras. MATERIALS AND METHODS: We performed a retrospective analysis of 86 sphincters placed at a single institution between December 1997 and September 2012. We assessed patient demographic, comorbid disease and surgical characteristics. All nonfunctioning, eroded or infected devices were considered failures. RESULTS: Of the 86 patients reviewed 67 (78%) had compromised urethras and had higher failure rates than the noncompromised group (34% vs 21%, p=0.02). Compared to the noncompromised group, cases of prior radiation therapy (HR 4.78; 95% CI 1.27, 18.04), urethroplasty (HR 8.61; 95% CI 1.27, 58.51) and previous artificial urinary sphincter placement (HR 8.14; 95% CI 1.71, 38.82) had a significantly increased risk of failure. The risk of artificial urinary sphincter failure increased with more prior procedures. An increased risk of failure was observed after 3.5 cm cuff placement (HR 8.62; 95% CI 2.82, 26.36) but not transcorporal placement (HR 1.21; 95% CI 0.49, 2.99). CONCLUSIONS: Artificial urinary sphincter placement in patients with compromised urethras from prior artificial urinary sphincter placement, radiation or urethroplasty had a statistically significant higher risk of failure than placement in patients with noncompromised urethras. Urethral mobilization and transection performed during posterior urethroplasty surgeries likely compromise urethral blood supply, predisposing patients to failure. Patients with severely compromised urethras from multiple prior procedures may have improved outcomes with transcorporal cuff placement rather than a 3.5 cm cuff.


Assuntos
Falha de Prótese , Uretra/efeitos da radiação , Uretra/cirurgia , Esfíncter Urinário Artificial , Idoso , Humanos , Pessoa de Meia-Idade , Implantação de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...