Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Hypertens ; 36(9): 1798-1802, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29927840

RESUMO

BACKGROUND: Self-measurement of blood pressure (BP) is increasingly being used for the diagnosis of hypertension and to monitor BP at home. Whenever compared with ambulatory BP measurements, home BP values are frequently higher and less predictive for incident cardiovascular events. We hypothesized that this could be caused by a pressor response elicited by the self-measurement of BP. METHODS: A total of 50 patients (mean age 62.0 ±â€Š11.2 years, 44% women) were included, 25 with and 25 without at least 10/5 mmHg higher home BP compared with daytime ambulatory BP. All patients performed 10 consecutive oscillometric BP measurements after 10 min of rest, followed by another resting period of 10 min, while continuously monitoring BP and central hemodynamics using finger photoplethysmography. Baseline BP before the start of the self-measurements was compared with the average BP during the first 10 s of inflation of the cuff. RESULTS: In both groups, we observed a significant increase in SBP and DBP during cuff inflation. The mean rise in average BP was 6.9 ±â€Š6.3/4.5 ±â€Š4.3 mmHg in the group with and 4.4 ±â€Š9.4/2.7 ±â€Š5.3 mmHg in the group without a BP difference between home and daytime ambulatory BP compared with baseline, whereas the maximum increase in average BP was 17.4/8.4 mmHg and 17.7/7.5 mmHg (P < 0 01). The increase in BP coincided with an increase in heart rate and cardiac output. BP differences attenuated after multiple readings, but did not disappear. CONCLUSION: Our results support the existence of a pressor response during self-BP measurement that remains present after multiple BP readings.


Assuntos
Determinação da Pressão Arterial , Pressão Sanguínea , Hipertensão/diagnóstico , Adulto , Idoso , Monitorização Ambulatorial da Pressão Arterial , Débito Cardíaco , Feminino , Dedos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Oscilometria , Fotopletismografia , Autoexame
2.
J Appl Physiol (1985) ; 122(2): 223-229, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27765843

RESUMO

Blood pressure (BP) decreases in the first weeks after Roux-and-Y gastric bypass surgery. Yet the pathophysiology of the BP-lowering effects observed after gastric bypass surgery is incompletely understood. We evaluated BP, systemic hemodynamics, and baroreflex sensitivity in 15 obese women[mean age 42 ± 7 standard deviation (SD) yr, body mass index 45 ± 6 kg/m2] 2 wk before and 6 wk following Roux-and-Y gastric bypass surgery. Six weeks after gastric bypass surgery, mean body weight decreased by 13 ± 5 kg (10%, P < 0.001). Office BP decreased from 137 ± 10/86 ± 6 to 128 ± 12/81 ± 9 mmHg (P < 0.001, P < 0.01), while daytime ambulatory BP decreased from 128 ± 14/80 ± 9 to 114 ± 10/73 ± 6 mmHg (P = 0.01, P = 0.05), whereas nighttime BP decreased from 111 ± 13/66 ± 7 to 102 ± 9/62 ± 7 mmHg (P = 0.04, P < 0.01). The decrease in BP was associated with a 1.6 ± 1.2 l/min (20%, P < 0.01) decrease in cardiac output (CO), while systemic vascular resistance increased (153 ± 189 dyn·s·cm-5, 15%, P < 0.01). The maximal ascending slope in systolic blood pressure decreased (192 mmHg/s, 19%, P = 0.01), suggesting a reduction in left ventricular contractility. Baroreflex sensitivity increased from 9.0 [6.4-14.3] to 13.8 [8.5-19.0] ms/mmHg (median [interquartile range]; P < 0.01) and was inversely correlated with the reductions in heart rate (R = -0.64, P = 0.02) and CO (R = -0.61, P = 0.03). In contrast, changes in body weight were not correlated with changes in either BP or CO. The BP reduction following Roux-and-Y gastric bypass surgery is correlated with a decrease in CO independent of changes in body weight. The contribution of heart rate to the reduction in CO together with enhanced baroreflex sensitivity suggests a shift toward increased parasympathetic cardiovascular control. NEW & NOTEWORTHY: The reason for the decrease in blood pressure (BP) in the first weeks after gastric bypass surgery remains to be elucidated. We show that the reduction in BP following surgery is caused by a decrease in cardiac output. In addition, the maximal ascending slope in systolic blood pressure decreased suggesting a reduction in left ventricular contractility and cardiac workload. These findings help to understand the physiological changes following gastric bypass surgery and are relevant in light of the increased risk of heart failure in these patients.


Assuntos
Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia , Derivação Gástrica/efeitos adversos , Adulto , Barorreflexo/fisiologia , Índice de Massa Corporal , Feminino , Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Obesidade/fisiopatologia , Obesidade/cirurgia , Sistema Nervoso Parassimpático/fisiologia , Resistência Vascular/fisiologia
3.
J Clin Monit Comput ; 26(4): 267-78, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22695821

RESUMO

Monitoring of continuous blood pressure and cardiac output is important to prevent hypoperfusion and to guide fluid administration, but only few patients receive such monitoring due to the invasive nature of most of the methods presently available. Noninvasive blood pressure can be determined continuously using finger cuff technology and cardiac output is easily obtained using a pulse contour method. In this way completely noninvasive continuous blood pressure and cardiac output are available for clinical use in all patients that would otherwise not be monitored. Developments and state of art in hemodynamic monitoring are reviewed here, with a focus on noninvasive continuous hemodynamic monitoring form the finger.


Assuntos
Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/tendências , Determinação do Volume Sanguíneo/métodos , Determinação do Volume Sanguíneo/tendências , Débito Cardíaco , Monitorização Ambulatorial/métodos , Monitorização Ambulatorial/tendências , Humanos
4.
Anesthesiology ; 116(5): 1092-103, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22415387

RESUMO

BACKGROUND: If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. METHODS: Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. RESULTS: NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. CONCLUSION: Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.


Assuntos
Artérias/fisiologia , Monitores de Pressão Arterial , Monitorização Intraoperatória/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Determinação da Pressão Arterial/instrumentação , Procedimentos Cirúrgicos Cardíacos , Ponte de Artéria Coronária , Estudos de Viabilidade , Feminino , Dedos/irrigação sanguínea , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Torácicos
6.
Hypertension ; 57(4): 738-45, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21357278

RESUMO

Type 2 diabetes mellitus is associated with microvascular complications, hypertension, and impaired dynamic cerebral autoregulation. Intensive blood pressure (BP) control in hypertensive type 2 diabetic patients reduces their risk of stroke but may affect cerebral perfusion. Systemic hemodynamic variables and transcranial Doppler-determined cerebral blood flow velocity (CBFV), cerebral CO2 responsiveness, and cognitive function were determined after 3 and 6 months of intensive BP control in 17 type 2 diabetic patients with microvascular complications (T2DM+), in 18 diabetic patients without (T2DM-) microvascular complications, and in 16 nondiabetic hypertensive patients. Cerebrovascular reserve capacity was lower in T2DM+ versus T2DM- and nondiabetic hypertensive patients (4.6±1.1 versus 6.0±1.6 [P<0.05] and 6.6±1.7 [P<0.01], Δ%mean CBFV/mm Hg). After 6 months, the attained BP was comparable among the 3 groups. However, in contrast to nondiabetic hypertensive patients, intensive BP control reduced CBFV in T2DM- (58±9 to 54±12 cm·s(-1)) and T2DM+ (57±13 to 52±11 cm·s(-1)) at 3 months, but CBFV returned to baseline at 6 months only in T2DM-, whereas the reduction in CBFV progressed in T2DM+ (to 48±8 cm·s(-1)). Cognitive function did not change during the 6 months. Static cerebrovascular autoregulation appears to be impaired in type 2 diabetes mellitus, with a transient reduction in CBFV in uncomplicated diabetic patients on tight BP control, but with a progressive reduction in CBFV in diabetic patients with microvascular complications, indicating that maintenance of cerebral perfusion during BP treatment depends on the progression of microvascular disease. We suggest that BP treatment should be individualized, aiming at a balance between BP reduction and maintenance of CBFV.


Assuntos
Anti-Hipertensivos/uso terapêutico , Circulação Cerebrovascular/efeitos dos fármacos , Diabetes Mellitus Tipo 2/fisiopatologia , Angiopatias Diabéticas/tratamento farmacológico , Hipertensão/tratamento farmacológico , Adulto , Idoso , Análise de Variância , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Circulação Cerebrovascular/fisiologia , Cognição/efeitos dos fármacos , Cognição/fisiologia , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Diabetes Mellitus Tipo 2/tratamento farmacológico , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/fisiopatologia , Feminino , Humanos , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Fotopletismografia , Ultrassonografia Doppler Transcraniana
7.
J Hypertens ; 29(4): 682-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21330938

RESUMO

OBJECTIVE: Pressure wave reflections are age-dependent and generally assumed to increase with increasing peripheral resistance. We sought to determine the effect of standing on wave reflection in healthy older and younger individuals and the influence of increased peripheral resistance. METHODS: During supine rest and active standing, continuous finger arterial blood pressure was measured. Data obtained in the supine period and after 1 and 5 min standing were analysed. Aortic pressure and flow, calculated from finger pressure, were used to derive forward and backward pressure waves, reflection magnitude (ratio of backward and forward pressure waves), augmentation index, and peripheral resistance. RESULTS: Fifteen healthy older (aged 53±7 years) and 15 healthy younger (aged 29±5 years) individuals were included. In both groups, upon standing, stroke volume, cardiac output and pulse pressure decreased with an increase in heart rate and in diastolic pressure. In the older group peripheral resistance increased from 1.3±0.4 to 1.5±0.4 and 1.5±0.4 for supine, 1 and 5 min standing, whereas reflection magnitude decreased from 0.67±0.1 to 0.61±0.1 and 0.61±0.1, and augmentation index from 33±11 to 23±12 and 25±11. In the younger group peripheral resistance increased from 0.9±0.2 to 1.1±0.2 and 1.1±0.2, whereas reflection magnitude decreased from 0.55±0.05 to 0.48±0.05 and 0.49±0.05 and augmentation index from 18±11 to 1±18 and 4±19. CONCLUSION: With standing, haemodynamic variables change similarly in older and younger individuals. The opposite changes in reflection magnitude and peripheral resistance suggest that reflection and pressure augmentation are not solely dependent on peripheral resistance.


Assuntos
Postura , Resistência Vascular , Adulto , Estudos de Casos e Controles , Humanos , Pessoa de Meia-Idade
8.
Mol Med ; 17(3-4): 180-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21203694

RESUMO

Although a relation between diminished human immunity and stress is well recognized both within the general public and the scientific literature, the molecular mechanisms by which stress alters immunity remain poorly understood. We explored a novel model for acute human stress involving volunteers performing a first-time bungee jump from an altitude of 60 m and exploited this model to characterize the effects of acute stress in the peripheral blood compartment. Twenty volunteers were included in the study; half of this group was pretreated for 3 d with the ß-receptor blocking agent propranolol. Blood was drawn 2 h before, right before, immediately after and 2 h after the jump. Plasma catecholamine and cortisol levels increased significantly during jumping, which was accompanied by significantly reduced ex vivo inducibility of proinflammatory cytokines as well as activation of coagulation and vascular endothelium. Kinome profiles obtained from the peripheral blood leukocyte fraction contained a strong noncanonical glucocorticoid receptor signal transduction signature after jumping. In apparent agreement, jumping down-regulated Lck/Fyn and cellular innate immune effector function (phagocytosis). Pretreatment of volunteers with propranolol abolished the effects of jumping on coagulation and endothelial activation but left the inhibitory effects on innate immune function intact. Taken together, these results indicate that bungee jumping leads to a catecholamine-independent immune suppressive phenotype and implicate noncanonical glucocorticoid receptor signal transduction as a major pathway linking human stress to impaired functioning of the human innate immune system.


Assuntos
Altitude , Imunidade Inata/fisiologia , Esportes , Estresse Fisiológico/fisiologia , Adolescente , Antagonistas Adrenérgicos beta/farmacologia , Adulto , Coagulação Sanguínea/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Catecolaminas/sangue , Citocinas/metabolismo , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hidrocortisona/sangue , Imunidade Inata/efeitos dos fármacos , Contagem de Leucócitos , Leucócitos/citologia , Leucócitos/efeitos dos fármacos , Leucócitos/metabolismo , Lipopolissacarídeos/farmacologia , Masculino , Fosfotransferases/metabolismo , Propranolol/farmacologia , Estudos Prospectivos , Transdução de Sinais/efeitos dos fármacos , Adulto Jovem
9.
Clin Sci (Lond) ; 120(4): 161-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20828371

RESUMO

Acute psychological stress challenges the cardiovascular system with an increase in BP (blood pressure), HR (heart rate) and reduced BRS (baroreflex sensitivity). ß-adrenergic blockade enhances BRS during rest, but its effect on BRS during acute psychological stress is unknown. This study tested the hypothesis that BRS is higher during acute psychological stress in healthy subjects under ß-adrenergic blockade. Twenty healthy novice male bungee jumpers were randomized and studied with (PROP, n=10) or without (CTRL, n=10) propranolol. BP and HR responses and BRS [cross-correlation time-domain (BRSTD) and cross-spectral frequency-domain (BRSFD) analysis] were evaluated from 30 min prior up to 2 h after the jump. HR, cardiac output and pulse pressure were lower in the PROP group throughout the study. Prior to the bungee jump, BRS was higher in the PROP group compared with the CTRL group [BRSTD: 28 (24-42) compared with 17 (16-28) ms·mmHg-1, P<0.05; BRSFD: 27 (20-34) compared with 14 (9-19) ms·mmHg-1, P<0.05; values are medians (interquartile range)]. BP declined after the jump in both groups, and post-jump BRS did not differ between the groups. In conclusion, during acute psychological stress, BRS is higher in healthy subjects treated with non-selective ß-adrenergic blockade with significantly lower HR but comparable BP.


Assuntos
Antagonistas Adrenérgicos beta/farmacologia , Barorreflexo/efeitos dos fármacos , Estresse Psicológico/fisiopatologia , Doença Aguda , Adulto , Barorreflexo/fisiologia , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Propranolol/farmacologia , Adulto Jovem
12.
Eur J Appl Physiol ; 109(2): 141-57, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20052592

RESUMO

The Frank-Starling mechanism describes the relationship between stroke volume and preload to the heart, or the volume of blood that is available to the heart--the central blood volume. Understanding the role of the central blood volume for cardiovascular control has been complicated by the fact that a given central blood volume may be associated with markedly different central vascular pressures. The central blood volume varies with posture and, consequently, stroke volume and cardiac output (Q) are affected, but with the increased central blood volume during head-down tilt, stroke volume and Q do not increase further indicating that in the supine resting position the heart operates on the plateau of the Frank-Starling curve which, therefore, may be taken as a functional definition of normovolaemia. Since the capacity of the vascular system surpasses the blood volume, orthostatic and environmental stress including bed rest/microgravity, exercise and training, thermal loading, illness, and trauma/haemorrhage is likely to restrict venous return and Q. Consequently the cardiovascular responses are determined primarily by their effect on the central blood volume. Thus during environmental stress, flow redistribution becomes dependent on sympathetic activation affecting not only skin and splanchnic blood flow, but also flow to skeletal muscles and the brain. This review addresses the hypothesis that deviations from normovolaemia significantly influence these cardiovascular responses.


Assuntos
Volume Sanguíneo , Repouso em Cama/efeitos adversos , Exercício Físico/fisiologia , Hemorragia/fisiopatologia , Temperatura Alta , Humanos , Intolerância Ortostática/etiologia , Intolerância Ortostática/fisiopatologia , Postura/fisiologia , Choque/fisiopatologia , Estresse Fisiológico , Ausência de Peso/efeitos adversos
13.
Blood ; 114(16): 3473-8, 2009 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-19700663

RESUMO

Sickle cell disease (SCD) is associated with a high incidence of ischemic stroke. SCD is characterized by hemolytic anemia, resulting in reduced nitric oxide-bioavailability, and by impaired cerebrovascular hemodynamics. Cerebrovascular CO2 responsiveness is nitric oxide dependent and has been related to an increased stroke risk in microvascular diseases. We questioned whether cerebrovascular CO2 responsiveness is impaired in SCD and related to hemolytic anemia. Transcranial Doppler-determined mean cerebral blood flow velocity (V(mean)), near-infrared spectroscopy-determined cerebral oxygenation, and end-tidal CO2 tension were monitored during normocapnia and hypercapnia in 23 patients and 16 control subjects. Cerebrovascular CO2 responsiveness was quantified as Delta% V(mean) and Deltamicromol/L cerebral oxyhemoglobin, deoxyhemoglobin, and total hemoglobin per mm Hg change in end-tidal CO2 tension. Both ways of measurements revealed lower cerebrovascular CO2 responsiveness in SCD patients versus controls (V(mean), 3.7, 3.1-4.7 vs 5.9, 4.6-6.7 Delta% V(mean) per mm Hg, P < .001; oxyhemoglobin, 0.36, 0.14-0.82 vs 0.78, 0.61-1.22 Deltamicromol/L per mm Hg, P = .025; deoxyhemoglobin, 0.35, 0.14-0.67 vs 0.58, 0.41-0.86 Deltamicromol/L per mm Hg, P = .033; total-hemoglobin, 0.13, 0.02-0.18 vs 0.23, 0.13-0.38 Deltamicromol/L per mm Hg, P = .038). Cerebrovascular CO2 responsiveness was not related to markers of hemolytic anemia. In SCD patients, impaired cerebrovascular CO2 responsiveness reflects reduced cerebrovascular reserve capacity, which may play a role in pathophysiology of stroke.


Assuntos
Anemia Falciforme/fisiopatologia , Isquemia Encefálica/fisiopatologia , Circulação Cerebrovascular , Acidente Vascular Cerebral/fisiopatologia , Adulto , Anemia Falciforme/sangue , Anemia Falciforme/complicações , Anemia Falciforme/epidemiologia , Velocidade do Fluxo Sanguíneo , Isquemia Encefálica/sangue , Isquemia Encefálica/epidemiologia , Isquemia Encefálica/etiologia , Dióxido de Carbono/sangue , Feminino , Hemoglobinas/análise , Humanos , Incidência , Masculino , Óxido Nítrico/sangue , Oxigênio/sangue , Oxiemoglobinas/análise , Fatores de Risco , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
14.
J Appl Physiol (1985) ; 107(3): 816-23, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19574504

RESUMO

In the upright position, cerebral blood flow is reduced, maybe because arterial carbon dioxide partial pressure (Pa(CO(2))) decreases. We evaluated the time-dependent influence of a reduction in Pa(CO(2)), as indicated by the end-tidal Pco(2) tension (Pet(CO(2))), on cerebral perfusion during head-up tilt. Mean arterial pressure, cardiac output, middle cerebral artery mean flow velocity (MCA V(mean)), and dynamic cerebral autoregulation at supine rest and 70 degrees head-up tilt were determined during free breathing and with Pet(CO(2)) clamped to the supine level. The postural changes in central hemodynamic variables were equivalent, and the cerebrovascular autoregulatory capacity was not significantly affected by tilt or by clamping Pet(CO(2)). In the first minute of tilt, the decline in MCA V(mean) (10 +/- 4 vs. 3 +/- 4 cm/s; mean +/- SE; P < 0.05) and Pet(CO(2)) (6.8 +/- 4.3 vs. 1.7 +/- 1.6 Torr; P < 0.05) was larger during spontaneous breathing than during isocapnic tilt. However, after 2 min in the head-up position, the reduction in MCA V(mean) was similar (7 +/- 5 vs. 6 +/- 3 cm/s), although the spontaneous decline in Pet(CO(2)) was maintained (P < 0.05 vs. isocapnic tilt). These results suggest that the potential contribution of Pa(CO(2)) to the postural reduction in MCA V(mean) is transient, leaving the mechanisms for the sustained restrain in MCA V(mean) to be identified.


Assuntos
Dióxido de Carbono/sangue , Circulação Cerebrovascular/fisiologia , Postura/fisiologia , Adulto , Pressão Sanguínea/fisiologia , Humanos , Masculino , Artéria Cerebral Média/fisiologia , Mecânica Respiratória/fisiologia , Estresse Mecânico , Decúbito Dorsal/fisiologia , Adulto Jovem
15.
Stroke ; 40(3): 808-14, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19150866

RESUMO

BACKGROUND AND PURPOSE: Sickle cell disease (SCD) is associated with cerebral hyperperfusion and an increased risk of stroke. Also, both recurrent microvascular obstruction and chronic hemolysis affect endothelial function, potentially interfering with systemic and cerebral blood flow control. We addressed the question whether cerebrovascular control in patients with SCD is affected and related to hemolysis. METHODS: Systemic and cerebrovascular control were studied in 18 patients with SCD and 10 healthy subjects. Dynamic cerebral autoregulation was evaluated by transfer function analysis assessing the relationship between mean cerebral blood flow velocity and mean arterial pressure. RESULTS: Normal baroreflex sensitivity and postural cardiovascular reflex responses indicated integrity of systemic cardiovascular control. In the low- (0.07 to 0.15 Hz) frequency region, mean arterial pressure variability was comparable for both groups, but a larger mean cerebral blood flow velocity variability in SCD (6.1 [4.6 to 7.0] versus 4.2 [2.6 to 5.2] [cm x s(-1)](2) x Hz(-1); P<0.05) indicated a reduced capacity to buffer the transfer of blood pressure surges to the cerebral tissue. Impairment of dynamic cerebrovascular control was confirmed by a reduced mean arterial pressure-to-mean cerebral blood flow velocity transfer function phase lead in SCD versus healthy subjects (32+/-17 degrees versus 50+/-19 degrees , P<0.05) that was unrelated to the severity of hemolysis. CONCLUSIONS: In patients with SCD, dynamic cerebral autoregulation is impaired but appears unrelated to hemolysis.


Assuntos
Anemia Falciforme/fisiopatologia , Circulação Cerebrovascular/fisiologia , Homeostase/fisiologia , Adulto , Anemia Falciforme/diagnóstico por imagem , Contagem de Células Sanguíneas , Pressão Sanguínea/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Hemodinâmica/fisiologia , Hemólise/fisiologia , Humanos , Masculino , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA