Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IUCrJ ; 8(Pt 1): 124-130, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33520248

RESUMO

X-ray photon correlation spectroscopy (XPCS) is a routine technique to study slow dynamics in complex systems at storage-ring sources. Achieving nanosecond time resolution with the conventional XPCS technique is, however, still an experimentally challenging task requiring fast detectors and sufficient photon flux. Here, the result of a nanosecond XPCS study of fast colloidal dynamics is shown by employing an adaptive gain integrating pixel detector (AGIPD) operated at frame rates of the intrinsic pulse structure of the storage ring. Correlation functions from single-pulse speckle patterns with the shortest correlation time of 192 ns have been calculated. These studies provide an important step towards routine fast XPCS studies at storage rings.

2.
Nat Commun ; 11(1): 4511, 2020 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-32908128

RESUMO

Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported.


Assuntos
Cristalografia/instrumentação , Elétrons , Dispositivos Lab-On-A-Chip , Lasers , Aldeído Liases/ultraestrutura , Proteínas de Escherichia coli/ultraestrutura , Hidrodinâmica
3.
J Synchrotron Radiat ; 26(Pt 1): 74-82, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30655470

RESUMO

The Adaptive Gain Integrating Pixel Detector (AGIPD) is an X-ray imager, custom designed for the European X-ray Free-Electron Laser (XFEL). It is a fast, low-noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 104 photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.

4.
J Synchrotron Radiat ; 23(1): 111-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698052

RESUMO

With the increased brilliance of state-of-the-art synchrotron radiation sources and the advent of free-electron lasers (FELs) enabling revolutionary science with EUV to X-ray photons comes an urgent need for suitable photon imaging detectors. Requirements include high frame rates, very large dynamic range, single-photon sensitivity with low probability of false positives and (multi)-megapixels. At DESY, one ongoing development project - in collaboration with RAL/STFC, Elettra Sincrotrone Trieste, Diamond, and Pohang Accelerator Laboratory - is the CMOS-based soft X-ray imager PERCIVAL. PERCIVAL is a monolithic active-pixel sensor back-thinned to access its primary energy range of 250 eV to 1 keV with target efficiencies above 90%. According to preliminary specifications, the roughly 10 cm × 10 cm, 3.5k × 3.7k monolithic sensor will operate at frame rates up to 120 Hz (commensurate with most FELs) and use multiple gains within 27 µm pixels to measure 1 to ∼100000 (500 eV) simultaneously arriving photons. DESY is also leading the development of the AGIPD, a high-speed detector based on hybrid pixel technology intended for use at the European XFEL. This system is being developed in collaboration with PSI, University of Hamburg, and University of Bonn. The AGIPD allows single-pulse imaging at 4.5 MHz frame rate into a 352-frame buffer, with a dynamic range allowing single-photon detection and detection of more than 10000 photons at 12.4 keV in the same image. Modules of 65k pixels each are configured to make up (multi)megapixel cameras. This review describes the AGIPD and the PERCIVAL concepts and systems, including some recent results and a summary of their current status. It also gives a short overview over other FEL-relevant developments where the Photon Science Detector Group at DESY is involved.

5.
Rev Sci Instrum ; 79(3): 035106, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18377044

RESUMO

We examined the high precision deposition of toner and polymer microparticles with a typical size of approximately 10 microm on electrode arrays with electrodes of 100 microm and below using custom-made microelectronic chips. Selective desorption of redundant particles was employed to obtain a given particle pattern from preadsorbed particle layers. Microparticle desorption was regulated by dielectrophoretic attracting forces generated by individual pixel electrodes, tangential detaching forces of an air flow, and adhesion forces on the microchip surface. A theoretical consideration of the acting forces showed that without pixel voltage, the tangential force applied for particle detachment exceeded the particle adhesion force. When the pixel voltage was switched on, however, the sum of attracting forces was larger than the tangential detaching force, which was crucial for desorption efficiency. In our experiments, appropriately large dielectrophoretic forces were achieved by applying high voltages of up to 100 V on the pixel electrodes. In addition, electrode geometries on the chip's surface as well as particle size influenced the desorption quality. We further demonstrated the compatibility of this procedure to complementary metal oxide semiconductor chip technology, which should allow for an easy technical implementation with respect to high-resolution microparticle deposition.


Assuntos
Procedimentos Analíticos em Microchip/métodos , Microeletrodos , Polímeros , Eletricidade , Tamanho da Partícula , Semicondutores , Propriedades de Superfície
6.
Science ; 318(5858): 1888, 2007 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-18096799

RESUMO

Arrays promise to advance biology through parallel screening for binding partners. We show the combinatorial in situ synthesis of 40,000 peptide spots per square centimeter on a microchip. Our variant Merrifield synthesis immobilizes activated amino acids as monomers within particles, which are successively attracted by electric fields generated on each pixel electrode of the chip. With all different amino acids addressed, particles are melted at once to initiate coupling. Repetitive coupling cycles should allow for the translation of whole proteomes into arrays of overlapping peptides that could be used for proteome research and antibody profiling.


Assuntos
Técnicas de Química Combinatória , Peptídeos/síntese química , Aminoácidos/química , Eletricidade , Análise Serial de Proteínas/métodos
7.
Rev Sci Instrum ; 78(7): 075111, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17672797

RESUMO

In this study examples for a noncontact procedure that allow the description of instant electric charging of moving microparticles that contact dielectric surfaces, for instance, of a flow hose are presented. The described principle is based on the measurement of induced currents in grounded metal wire probes, as moving particles pass close to the probe. The feasibility of the approach was tested with laser printer toner particles of a given size for different basic particle flow and charging conditions. An analytic description for the induced currents was developed and compared to observed effects in order to interpret the results qualitatively. The implementation of the presented procedure can be applied to transparent and nontransparent particle containers and flow lines of complex geometry which can be composed from the presented basic flow stream configurations.


Assuntos
Eletroquímica/instrumentação , Teste de Materiais/instrumentação , Eletricidade Estática , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais/métodos , Microesferas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...