Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Diagnostics (Basel) ; 13(13)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37443612

RESUMO

The emergence of COVID-19 has caused unprecedented impacts on global public health and many other aspects. Meanwhile, many types of methods have been developed to detect the causative agent, SARS-CoV-2; this has greatly advanced the technologies in the diagnostic field. Here, we describe the development and validation of a sample-in-result-out POCKIT Central SARS-CoV-2 PCR system for detecting SARS-CoV-2 in comparison with a commercial reference real-time RT-PCR assay (TaqPath COVID-19 Combo Kit). Both assays were specific and did not cross-react with non-SARS-CoV-2 agents. Both assays were able to detect various SARS-CoV-2 strains including some variants. Based on testing serial dilutions of SARS-CoV-2 USA-WA1/2020 isolate, the limit of detection was 0.8 TCID50/mL (1.87 × 103 genomic copies/mL) for POCKIT Central SARS-CoV-2 PCR and 0.16 TCID50/mL (3.75 × 102 genomic copies/mL) for the reference PCR. Subsequently, 183 clinical samples were tested by both assays and the diagnostic sensitivity, specificity, and agreement of the POCKIT Central SARS-CoV-2 PCR were 91.7%, 100%, and 94.0%, respectively, when compared to the reference PCR. The compact sample-to-result POCKIT Central SARS-CoV-2 PCR system is a simplified and efficient point-of-care tool for SARS-CoV-2 detection. In addition, this platform can be readily adapted to detect other human and animal viruses.

2.
Influenza Other Respir Viruses ; 13(6): 610-617, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31487118

RESUMO

BACKGROUND: Avian influenza A (H7N9) remains circulating in China. For countries at risk of introduction of H7N9, such as Vietnam, early detection of H7N9 virus is essential for the early containment of the virus. Insulated isothermal reverse transcriptase PCR (iiRT-PCR) is a portable PCR system that can be deployed under field conditions to identify pathogens at the sampling site. Applying PCR at the sampling site will greatly reduce the time to obtain a diagnostic result which allows the veterinary authority to take immediate action to contain disease spreading. OBJECTIVE: To determine analytical and diagnostic sensitivity and specificity of the portable iiRT-PCR for H7N9 virus detection. METHODS: A panel of 59 virus isolates, including H7N9, avian influenza viruses of subtype H1 to H13, swine and human influenza viruses, Newcastle disease virus, and infectious bursal disease virus, were tested by H7 and N9 iiRT-PCR reagents, using probes and primers specific to H7 or N9, in comparison with laboratory-based real-time RT-PCR assays to determine analytical sensitivity and specificity. Fifty oropharyngeal samples from experimentally infected chicken and ducks with H7N9 and 50 non-infected control swabs were tested by the H7 iiRT-PCR to determine diagnostic sensitivity and specificity. RESULTS: The H7 and N9 iiRT-PCR reagents yielded comparable levels of analytical sensitivity and specificity with real-time RT-PCR for the detection of H7N9 virus. Diagnostic sensitivity and specificity of H7 iiRT-PCR were 98% and 100%, respectively. CONCLUSION: The observed high sensitivity and specificity of iiRT-PCR for H7N9 detection show its potential for early detection of H7N9 in risk-based surveillance.


Assuntos
Subtipo H7N9 do Vírus da Influenza A/genética , Influenza Aviária/diagnóstico , Influenza Aviária/virologia , Técnicas de Diagnóstico Molecular/veterinária , Reação em Cadeia da Polimerase/veterinária , Animais , Galinhas , Patos , Subtipo H7N9 do Vírus da Influenza A/classificação , Subtipo H7N9 do Vírus da Influenza A/isolamento & purificação , Orofaringe/virologia , Testes Imediatos , Sensibilidade e Especificidade , Vietnã
3.
PLoS One ; 14(7): e0218139, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31291289

RESUMO

BACKGROUND: The insulated isothermal PCR (iiPCR) technology enables consistent PCR amplification and detection in a simple heating device. A pan-dengue virus (DENV) RT-iiPCR, targeting the 5' untranslated region, was validated previously on the semi-automated POCKIT combo system (involving separate devices for nucleic acid extraction and PCR amplification/detection) to offer performance comparable to a laboratory real-time PCR. Working on the same technologies, a compact automated sample-in-answer-out system (POCKIT Central Nucleic Acid Analyser) has been available commercially for iiPCR, minimizing human error risks and allowing easy molecular bio-detection near points of need. Here, we evaluated the analytical and clinical performance of the pan-DENV RT-iiPCR on the fully automated system by comparison to those on the semi-automated system. METHODOLOGY/PRINCIPAL FINDINGS: Testing sera containing serial diluted DENV-1, -2, -3, or -4 cell culture stock, the pan-DENV RT-iiPCR system had similar 100% detection endpoints on the two systems; i.e. at 1, 10, 1 and 10 PFU/ml, respectively, on the fully automated system, and at 10, 1, 10 and 10 PFU/ml, respectively, on the semi-automated system. Furthermore, both fully automated and semi-automated PCR system can detect all four DENV serotypes in mosquitos. Clinical performance of the reagent on the two systems was evaluated by testing 60 human serum samples. Both systems detected the same 40 samples (ten DENV-1, -2, -3, and -4 positive each) and did not detect the other 20; 100% agreement (κ = 1) was found between the two systems. CONCLUSIONS/SIGNIFICANCE: With performance comparable to a previously validated system, the fully-automated PCR system allows applications of the pan-DENV reagent as a useful tool near points of need to facilitate easy, fast and effective detection of dengue virus and help mitigate versatile public health challenges in the control and management of dengue disease.


Assuntos
Culicidae/virologia , Vírus da Dengue/isolamento & purificação , Dengue/sangue , Adulto , Idoso , Animais , Dengue/virologia , Vírus da Dengue/genética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito/economia , Reação em Cadeia da Polimerase/economia , Reação em Cadeia da Polimerase/métodos , Adulto Jovem
4.
BMC Vet Res ; 15(1): 168, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-31126297

RESUMO

BACKGROUND: Seneca Valley virus (SVV) has emerged in multiple countries in recent years. SVV infection can cause vesicular lesions clinically indistinguishable from those caused by other vesicular disease viruses, such as foot-and-mouth disease virus (FMDV), swine vesicular disease virus (SVDV), vesicular stomatitis virus (VSV), and vesicular exanthema of swine virus (VESV). Sensitive and specific RT-PCR assays for the SVV detection is necessary for differential diagnosis. Real-time RT-PCR (rRT-PCR) has been used for the detection of many RNA viruses. The insulated isothermal PCR (iiPCR) on a portable POCKIT™ device is user friendly for on-site pathogen detection. In the present study, SVV rRT-PCR and RT-iiPCR were developed and validated. RESULTS: Neither the SVV rRT-PCR nor the RT-iiPCR cross-reacted with any of the vesicular disease viruses (20 FMDV, two SVDV, six VSV, and two VESV strains), classical swine fever virus (four strains), and 15 other common swine viruses. Analytical sensitivities of the SVV rRT-PCR and RT-iiPCR were determined using serial dilutions of in vitro transcribed RNA as well as viral RNA extracted from a historical SVV isolate and a contemporary SVV isolate. Diagnostic performances were further evaluated using 125 swine samples by two approaches. First, nucleic acids were extracted from the 125 samples using the MagMAX™ kit and then tested by both RT-PCR methods. One sample was negative by the rRT-PCR but positive by the RT-iiPCR, resulting in a 99.20% agreement (124/125; 95% CI: 96.59-100%, κ = 0.98). Second, the 125 samples were tested by the taco™ mini extraction/RT-iiPCR and by the MagMAX™ extraction/rRT-PCR system in parallel. Two samples were positive by the MagMAX™/rRT-PCR system but negative by the taco™ mini/RT-iiPCR system, resulting in a 98.40% agreement (123/125; 95% CI: 95.39-100%, κ = 0.97). The two samples with discrepant results had relatively high CT values. CONCLUSIONS: The SVV rRT-PCR and RT-iiPCR developed in this study are very sensitive and specific and have comparable diagnostic performances for SVV RNA detection. The SVV rRT-PCR can be adopted for SVV detection in laboratories. The SVV RT-iiPCR in a simple field-deployable system could serve as a tool to help diagnose vesicular diseases in swine at points of need.


Assuntos
Picornaviridae/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária , Doenças dos Suínos/virologia , Animais , Variação Genética , Picornaviridae/genética , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sensibilidade e Especificidade , Suínos , Doenças dos Suínos/diagnóstico
5.
J Virol Methods ; 259: 116-121, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29902491

RESUMO

Bovine leukemia virus (BLV) is a contagious, oncogenic deltaretrovirus of cattle with a worldwide distribution. In the US, over 40% of dairy cows are infected with the virus, and evidence of its economic impact is growing. This study evaluated the performance of a field-deployable automatic nucleic acid-extraction/insulated isothermal PCR (iiPCR) system for on-site BLV-proviral DNA detection in dairy cows compared with a conventional laboratory real-time PCR (rt-PCR). Assay performance was verified in parallel tests of 36 archived blood samples with 100% agreement (κ = 1.0; n = 36) between the iiPCR and conventional rt-PCR systems, and the limit of detection of the iiPCR assay was estimated to be 4 copies (genome equivalent) per reaction. The field-deployable iiPCR system was subsequently used on-farm to test freshly collected blood samples, and showed 100% agreement (κ = 1.0; n = 32) with the laboratory rt-PCR system. Fresh blood samples were collected on a second farm and tested on both systems, also with 100% agreement (κ = 1.0; n = 34). The field-deployable iiPCR/POCKIT™ combo system performs as well as a conventional laboratory-based rt-PCR system for detection of BLV proviral DNA in whole blood and may be a useful tool for on-farm evaluation of BLV-infection status in dairy cattle.


Assuntos
DNA Viral/isolamento & purificação , Leucose Enzoótica Bovina/diagnóstico , Vírus da Leucemia Bovina/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Testes Imediatos , Reação em Cadeia da Polimerase/métodos , Provírus/isolamento & purificação , Animais , Automação/métodos , Bovinos , DNA Viral/genética , Leucose Enzoótica Bovina/virologia , Vírus da Leucemia Bovina/genética , Provírus/genética
6.
J Clin Microbiol ; 56(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29436418

RESUMO

Dengue virus (DENV) infection, a mosquito-borne disease, is a major public health problem in tropical countries. Point-of-care DENV detection with good sensitivity and specificity enables timely early diagnosis of DENV infection, facilitating effective disease management and control, particularly in regions of low resources. The Pockit dengue virus reagent set (GeneReach Biotech), a reverse transcription insulated isothermal PCR (RT-iiPCR), is available to detect all four serotypes of DENV on the field-deployable Pockit system, which is ready for on-site applications. In this study, analytical and clinical performances of the assay were evaluated. The index assay did not react with 14 non-DENV human viruses, indicating good specificity. Compared to the U.S. CDC DENV-1-4 real-time quantitative RT-PCR (qRT-PCR) assay, testing with serial dilutions of virus-spiked human sera demonstrated that the index assay had detection endpoints that were separately comparable with the 4 serotypes. Excellent reproducibility was observed among repeat tests done by six operators at three sites. In clinical performance, 195 clinical sera collected around Kaohsiung city in 2012 and 21 DENV-4-spiked sera were tested with the RT-iiPCR and qRT-PCR assays in parallel. The 121 (11 DENV-1, 78 DENV-2, 11 DENV-3, and 21 DENV-4) qRT-PCR-positive and 95 qRT-PCR-negative samples were all positive and negative by the RT-iiPCR reagent results, respectively, demonstrating high (100%) interrater agreement (95% confidence interval [CI95%], ∼98.81% to 100%; κ = 1). With analytical and clinical performance equivalent to those of the reference qRT-PCR assay, the index PCR assay on the field-deployable system can serve as a highly sensitive and specific on-site tool for DENV detection.


Assuntos
Vírus da Dengue/isolamento & purificação , Dengue/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Dengue/sangue , Vírus da Dengue/genética , Humanos , Técnicas de Diagnóstico Molecular/normas , RNA Viral/genética , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sorogrupo
7.
J Feline Med Surg ; 20(4): 362-369, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28589743

RESUMO

Objectives Feline leukaemia virus (FeLV), a gamma retrovirus, causes diseases of the feline haematopoietic system that are invariably fatal. Rapid and accurate testing at the point-of-need (PON) supports prevention of virus spread and management of clinical disease. This study evaluated the performance of an insulated isothermal PCR (iiPCR) that detects proviral DNA, and a reverse transcription (RT)-iiPCR that detects both viral RNA and proviral DNA, for FeLV detection at the PON. Methods Mycoplasma haemofelis, feline coronavirus, feline herpesvirus, feline calicivirus and feline immunodeficiency virus were used to test analytical specificity. In vitro transcribed RNA, artificial plasmid, FeLV strain American Type Culture Collection VR-719 and a clinical FeLV isolate were used in the analytical sensitivity assays. A retrospective study including 116 clinical plasma and serum samples that had been tested with virus isolation, real-time PCR and ELISA, and a prospective study including 150 clinical plasma and serum samples were implemented to evaluate the clinical performances of the iiPCR-based methods for FeLV detection. Results Ninety-five percent assay limit of detection was calculated to be 16 RNA and five DNA copies for the RT-iiPCR, and six DNA copies for the iiPCR. Both reactions had analytical sensitivity comparable to a reference real-time PCR (qPCR) and did not detect five non-target feline pathogens. The clinical performance of the RT-iiPCR and iiPCR had 98.82% agreement (kappa[κ] = 0.97) and 100% agreement (κ = 1.0), respectively, with the qPCR (n = 85). The agreement between an automatic nucleic extraction/RT-iiPCR system and virus isolation to detect FeLV in plasma or serum was 95.69% (κ = 0.95) and 98.67% (κ = 0.85) in a retrospective (n = 116) and a prospective (n = 150) study, respectively. Conclusions and relevance These results suggested that both RT-iiPCR and iiPCR assays can serve as reliable tools for PON FeLV detection.


Assuntos
Síndrome de Imunodeficiência Adquirida Felina/diagnóstico , Vírus da Imunodeficiência Felina/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Animais , Gatos , Síndrome de Imunodeficiência Adquirida Felina/virologia , Reação em Cadeia da Polimerase/veterinária , Estudos Prospectivos , RNA Viral/análise , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
J Mol Diagn ; 19(6): 817-827, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28807812

RESUMO

Middle East respiratory syndrome (MERS) is an emerging zoonotic viral respiratory disease that was first identified in Saudi Arabia in 2012. In 2015, the largest MERS outbreak outside of the Middle East region occurred in the Republic of Korea. The rapid nosocomial transmission of MERS-coronavirus (MERS-CoV) in Korean health care settings highlighted the importance and urgent need for a rapid and reliable on-site diagnostic assay to implement effective control and preventive measures. Here, the evaluation and validation of two newly developed reverse transcription-insulated isothermal PCR (RT-iiPCR) methods targeting the ORF1a and upE genes of MERS-CoV are described. Compared with World Health Organization-recommended singleplex real-time quantitative RT-PCR (RT-qPCR) assays, both RT-iiPCR assays had comparable analytical sensitivity for the detection of MERS-CoV RNA in tissue culture fluid and in sputum samples spiked with infectious virus. Furthermore, clinical evaluation was performed with sputum samples collected from subjects with acute and chronic respiratory illnesses, including patients infected with MERS-CoV. The overall agreement values between the two RT-iiPCR assays and the reference RT-qPCR assays were 98.06% (95% CI, 94.43%-100%; κ = 0.96) and 99.03% (95% CI, 95.88%-100%; κ = 0.99) for ORF1a and upE assays, respectively. The ORF1a and upE MERS-CoV RT-iiPCR assays coupled with a field-deployable system provide a platform for a highly sensitive and specific on-site tool for diagnosis of MERS-CoV infections.


Assuntos
Infecções por Coronavirus/diagnóstico , Coronavírus da Síndrome Respiratória do Oriente Médio/isolamento & purificação , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por Coronavirus/genética , Infecções por Coronavirus/virologia , Humanos , Coronavírus da Síndrome Respiratória do Oriente Médio/genética , Coronavírus da Síndrome Respiratória do Oriente Médio/patogenicidade , RNA Viral/genética , República da Coreia/epidemiologia , Transcrição Reversa/genética
9.
Poult Sci ; 96(1): 35-41, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27389062

RESUMO

Mycoplasma synoviae (MS), causing respiratory diseases, arthritis, and eggshell apex abnormalities in avian species, is an important pathogen in the poultry industry. Implementation of a biosecurity plan is important in MS infection management. Working on a field-deployable POCKIT™ device, an insulated isothermal polymerase chain reaction (iiPCR) assay has a potential for timely MS detection on the farm. The MS iiPCR assay had limit of detection 95% of about 9 genome equivalents by testing serial dilutions of a standard DNA. The detection endpoint of the assay for detection of MS genomic DNA was comparable to a reference real-time PCR. The assay did not crossreact with other important avian pathogens, including avian reovirus, Mycoplasma gallisepticum, Staphylococcus aureus, Escherichia coli, Pasteurella multocida, and Salmonella Pullorum. When 92 synovial fluid and respiratory tract swab samples collected from chickens, turkeys, and geese suspected of MS infection were tested, the clinical performance of the MS iiPCR had 97.8% agreement (Cohen's kappa value, 0.95) with that of the reference real-time PCR. In conclusion, the MS iiPCR/POCKIT™ system, working with field-deployable manual or automatic nucleic acid extraction methods, has potential to serve as a rapid and sensitive on-site tool to facilitate timely detection of MS.


Assuntos
Proteínas de Bactérias/isolamento & purificação , Galinhas , Lectinas/isolamento & purificação , Infecções por Mycoplasma/veterinária , Mycoplasma synoviae/isolamento & purificação , Doenças das Aves Domésticas/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Animais , Infecções por Mycoplasma/diagnóstico , Infecções por Mycoplasma/microbiologia , Doenças das Aves Domésticas/microbiologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sistema Respiratório/microbiologia , Sensibilidade e Especificidade , Líquido Sinovial/microbiologia
10.
J Virol Methods ; 241: 58-63, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27993615

RESUMO

Equine herpesvirus myeloencephalopathy (EHM), a major problem for the equine industry in the United States, is caused by equine herpesvirus-1 (EHV-1). In addition, EHV-1 is associated with upper respiratory disease, abortion, and chorioretinal lesions in horses. Here we describe the development and evaluation of an inexpensive, user-friendly insulated isothermal PCR (iiPCR) method targeting open reading 30 (ORF30) to detect both neuropathogenic and non-neuropathogenic strains on the field-deployable POCKIT™ device for point-of-need detection of EHV-1. The analytical sensitivity of the EHV-1 iiPCR assay was 13 genome equivalents per reaction. The assay did not cross react with ten non-target equine viral pathogens. Performance of the EHV-1 iiPCR assay was compared to two previously described real-time PCR (qPCR) assays in two laboratories by using 104 archived clinical samples. All 53 qPCR-positive and 46 of the 51 qPCR-negative samples tested positive and negative, respectively, by the iiPCR. The agreement between the two assays was 95.19% (confidence interval 90.48-99.90%) with a kappa value of 0.90. In conclusion, the newly developed EHV-1 iiPCR assay is robust to provide specificity and sensitivity comparable to qPCR assays for the detection of EHV-1 nucleic acid in clinical specimens.


Assuntos
Infecções por Herpesviridae/veterinária , Herpesvirus Equídeo 1/isolamento & purificação , Doenças dos Cavalos/diagnóstico , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Animais , DNA Viral/genética , DNA Viral/isolamento & purificação , Encefalomielite/diagnóstico , Encefalomielite/veterinária , Encefalomielite/virologia , Infecções por Herpesviridae/diagnóstico , Infecções por Herpesviridae/virologia , Herpesvirus Equídeo 1/genética , Doenças dos Cavalos/virologia , Cavalos , Fases de Leitura Aberta/genética , Reação em Cadeia da Polimerase/economia , Sensibilidade e Especificidade , Temperatura
11.
J Virol Methods ; 235: 99-104, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27180038

RESUMO

There is no gold standard for detection of Rotavirus Group A (RVA), one of the main causes of diarrhea in neonatal animals. Sensitive and specific real-time RT-PCR (rtRT-PCR) assays are available for RVA but require submission of the clinical samples to diagnostic laboratories. Patient-side immunoassays for RVA protein detection have shown variable results, particularly with samples from unintended species. A sensitive and specific test for detection of RVA on the farm would facilitate rapid management decisions. The insulated isothermal RT-PCR (RT-iiPCR) assay works in a portable machine to allow sensitive and specific on-site testing. The aim of this investigation was to evaluate a commercially available RT-iiPCR assay for RVA detection in feces from different animal species. This assay was compared to an in-house rtRT-PCR assay and a commercially available rtRT-PCR kit, as well as an ELISA and EM for RVA detection. All three PCR assays targeted the well-conserved NSP5 gene. Clinical fecal samples from 108 diarrheic animals (mainly cattle and horses) were tested. The percentage of positive samples by ELISA, EM, in-house rtRT-PCR, commercial rtRT-PCR, and RT-iiPCR was 29.4%, 31%, 36.7%, 51.4%, 56.9%, respectively. The agreement between different assays was high (81.3-100%) in samples containing high viral loads. The sensitivity of the RT-iiPCR assay appeared to be higher than the commercially available rtRT-PCR assay, with a limit of detection (95% confidence index) of 3-4 copies of in vitro transcribed dsRNA. In conclusion, the user-friendly, field-deployable RT-iiPCR system holds substantial promise for on-site detection of RVA.


Assuntos
Ensaio de Imunoadsorção Enzimática , Fezes/virologia , Microscopia Eletrônica , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Infecções por Rotavirus/veterinária , Rotavirus/isolamento & purificação , Animais , Bovinos , Doenças dos Bovinos/diagnóstico , Doenças dos Bovinos/virologia , Diarreia/virologia , Doenças dos Cavalos/diagnóstico , Doenças dos Cavalos/virologia , Cavalos , Sistemas Automatizados de Assistência Junto ao Leito , RNA de Cadeia Dupla , RNA Viral/genética , RNA Viral/isolamento & purificação , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Rotavirus/genética , Infecções por Rotavirus/diagnóstico , Infecções por Rotavirus/virologia , Sensibilidade e Especificidade , Temperatura , Carga Viral , Proteínas não Estruturais Virais/genética
12.
J Virol Methods ; 234: 34-42, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27060624

RESUMO

Recent outbreaks of porcine epidemic diarrhea virus (PEDV) and porcine deltacoronavirus (PDCoV) in multiple countries have caused significant economic losses and remain a serious challenge to the swine industry. Rapid diagnosis is critical for the implementation of efficient control strategies before and during PEDV and PDCoV outbreaks. Insulated isothermal PCR (iiPCR) on the portable POCKIT™ device is user friendly for on-site pathogen detection. In the present study, a singleplex PEDV RT-iiPCR, a singleplex PDCoV RT-iiPCR, and a duplex PEDV/PDCoV real-time RT-PCR (rRT-PCR) commercial reagents targeting the M gene were compared to an N gene-based PEDV rRT-PCR and an M gene-based PDCoV rRT-PCR that were previously published and used as reference PCRs. All PCR assays were highly specific and did not cross react with other porcine enteric pathogens. Analytical sensitivities of the PEDV RT-iiPCR, PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR were determined using in vitro transcribed RNA as well as viral RNA extracted from ten-fold serial dilutions of PEDV and PDCoV cell culture isolates. Performance of each PCR assay was further evaluated using 170 clinical samples (86 fecal swabs, 24 feces, 19 intestines, and 41 oral fluids). Compared to the reference PEDV rRT-PCR, the sensitivity, specificity and accuracy of the PEDV RT-iiPCR were 97.73%, 98.78%, and 98.24%, respectively, and those of the duplex PEDV/PDCoV rRT-PCR were 98.86%, 96.34%, and 97.65%, respectively. Compared to the reference PDCoV rRT-PCR, the sensitivity, specificity and accuracy of the PDCoV RT-iiPCR were 100%, 100%, and 100%, respectively, and those of the PEDV/PDCoV duplex rRT-PCR were 96.34%, 100%, and 98.24%, respectively. Overall, all three new PCR assays were comparable to the reference rRT-PCRs for detection of PEDV and/or PDCoV. The PEDV and PDCoV RT-iiPCRs are potentially useful tools for on-site detection and the duplex PEDV/PDCoV rRT-PCR provides a convenient method to simultaneously detect the two viruses and differentiate PEDV from PDCoV.


Assuntos
Coronaviridae/isolamento & purificação , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/veterinária , Reação em Cadeia da Polimerase/métodos , Vírus da Diarreia Epidêmica Suína/isolamento & purificação , Doenças dos Suínos/diagnóstico , Animais , Coronaviridae/genética , Infecções por Coronavirus/virologia , Fezes/virologia , Vírus da Diarreia Epidêmica Suína/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sensibilidade e Especificidade , Suínos , Doenças dos Suínos/virologia , Temperatura
13.
J Virol Methods ; 234: 7-15, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27036504

RESUMO

Equine arteritis virus (EAV) is the causative agent of equine viral arteritis (EVA), a respiratory and reproductive disease of horses. Most importantly, EAV induces abortion in pregnant mares and can establish persistent infection in up to 10-70% of the infected stallions, which will continue to shed the virus in their semen. The objective of this study was to develop and evaluate a reverse transcription insulated isothermal polymerase chain reaction (RT-iiPCR) for the detection of EAV in semen and tissue samples. The newly developed assay had a limit of detection of 10 RNA copies and a 10-fold higher sensitivity than a previously described real-time RT-PCR (RT-qPCR). Evaluation of 125 semen samples revealed a sensitivity and specificity of 98.46% and 100.00%, respectively for the RT-qPCR assay, and 100.00% and 98.33%, respectively for the RT-iiPCR assay. Both assays had the same accuracy (99.2%, k=0.98) compared to virus isolation. Corresponding values derived from testing various tissue samples (n=122) collected from aborted fetuses, foals, and EAV carrier stallions are as follows: relative sensitivity, specificity, and accuracy of 88.14%, 96.83%, and 92.62% (k=0.85), respectively for the RT-qPCR assay, and 98.31%, 92.06%, and 95.08% (k=0.90), respectively for the RT-iiPCR assay. These results indicate that RT-iiPCR is a sensitive, specific, and a robust test enabling detection of EAV in semen and tissue samples with very considerable accuracy. Even though the RT-qPCR assay showed a sensitivity and specificity equal to virus isolation for semen samples, its diagnostic performance was somewhat limited for tissue samples. Thus, this new RT-iiPCR could be considered as an alternative tool in the implementation of EAV control and prevention strategies.


Assuntos
Infecções por Arterivirus/veterinária , Equartevirus/isolamento & purificação , Doenças dos Cavalos/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária , Sêmen/virologia , Animais , Infecções por Arterivirus/diagnóstico , Infecções por Arterivirus/prevenção & controle , Infecções por Arterivirus/virologia , Feminino , Doenças dos Cavalos/virologia , Cavalos , Masculino , Fases de Leitura Aberta , Gravidez , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sensibilidade e Especificidade , Temperatura
14.
J Clin Microbiol ; 54(6): 1528-1535, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27030492

RESUMO

Dengue virus (DENV) infection is considered a major public health problem in developing tropical countries where the virus is endemic and continues to cause major disease outbreaks every year. Here, we describe the development of a novel, inexpensive, and user-friendly diagnostic assay based on a reverse transcription-insulated isothermal PCR (RT-iiPCR) method for the detection of all four serotypes of DENV in clinical samples. The diagnostic performance of the newly established pan-DENV RT-iiPCR assay targeting a conserved 3' untranslated region of the viral genome was evaluated. The limit of detection with a 95% confidence was estimated to be 10 copies of in vitro-transcribed (IVT) RNA. Sensitivity analysis using RNA prepared from 10-fold serial dilutions of tissue culture fluid containing DENVs suggested that the RT-iiPCR assay was comparable to the multiplex real-time quantitative RT-PCR (qRT-PCR) assay for DENV-1, -3, and -4 detection but 10-fold less sensitive for DENV-2 detection. Subsequently, plasma collected from patients suspected of dengue virus infection (n = 220) and individuals not suspected of dengue virus infection (n = 45) were tested by the RT-iiPCR and compared to original test results using a DENV NS1 antigen rapid test and the qRT-PCR. The diagnostic agreement of the pan-DENV RT-iiPCR, NS1 antigen rapid test, and qRT-PCR tests was 93.9%, 84.5%, and 97.4%, respectively, compared to the composite reference results. This new RT-iiPCR assay along with the portable POCKIT nucleic acid analyzer could provide a highly reliable, sensitive, and specific point-of-need diagnostic assay for the diagnosis of DENV in clinics and hospitals in developing countries.


Assuntos
Vírus da Dengue/isolamento & purificação , Dengue/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Vírus da Dengue/genética , Humanos , Sensibilidade e Especificidade
15.
J Vet Diagn Invest ; 27(4): 510-5, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26185125

RESUMO

Feline immunodeficiency virus (FIV) is an important infectious agent of cats. Clinical syndromes resulting from FIV infection include immunodeficiency, opportunistic infections, and neoplasia. In our study, a 5' long terminal repeat/gag region-based reverse transcription insulated isothermal polymerase chain reaction (RT-iiPCR) was developed to amplify all known FIV strains to facilitate point-of-need FIV diagnosis. The RT-iiPCR method was applied in a point-of-need PCR detection platform--a field-deployable device capable of generating automatically interpreted RT-iiPCR results from nucleic acids within 1 hr. Limit of detection 95% of FIV RT-iiPCR was calculated to be 95 copies standard in vitro transcription RNA per reaction. Endpoint dilution studies with serial dilutions of an ATCC FIV type strain showed that the sensitivity of lyophilized FIV RT-iiPCR reagent was comparable to that of a reference nested PCR. The established reaction did not amplify any nontargeted feline pathogens, including Felid herpesvirus 1, feline coronavirus, Feline calicivirus, Feline leukemia virus, Mycoplasma haemofelis, and Chlamydophila felis. Based on analysis of 76 clinical samples (including blood and bone marrow) with the FIV RT-iiPCR, test sensitivity was 97.78% (44/45), specificity was 100.00% (31/31), and agreement was 98.65% (75/76), determined against a reference nested-PCR assay. A kappa value of 0.97 indicated excellent correlation between these 2 methods. The lyophilized FIV RT-iiPCR reagent, deployed on a user-friendly portable device, has potential utility for rapid and easy point-of-need detection of FIV in cats.


Assuntos
Síndrome de Imunodeficiência Adquirida Felina/diagnóstico , Vírus da Imunodeficiência Felina/isolamento & purificação , Animais , Gatos , Síndrome de Imunodeficiência Adquirida Felina/virologia , Vírus da Imunodeficiência Felina/genética , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/veterinária , RNA Viral/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Virol Methods ; 220: 35-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25889355

RESUMO

Canine parvovirus type 2 (CPV-2), including subtypes 2a, 2b and 2c, causes an acute enteric disease in both domestic and wild animals. Rapid and sensitive diagnosis aids effective disease management at points of need (PON). A commercially available, field-deployable and user-friendly system, designed with insulated isothermal PCR (iiPCR) technology, displays excellent sensitivity and specificity for nucleic acid detection. An iiPCR method was developed for on-site detection of all circulating CPV-2 strains. Limit of detection was determined using plasmid DNA. CPV-2a, 2b and 2c strains, a feline panleukopenia virus (FPV) strain, and nine canine pathogens were tested to evaluate assay specificity. Reaction sensitivity and performance were compared with an in-house real-time PCR using serial dilutions of a CPV-2b strain and 100 canine fecal clinical samples collected from 2010 to 2014, respectively. The 95% limit of detection of the iiPCR method was 13 copies of standard DNA and detection limits for CPV-2b DNA were equivalent for iiPCR and real-time PCR. The iiPCR reaction detected CPV-2a, 2b and 2c and FPV. Non-targeted pathogens were not detected. Test results of real-time PCR and iiPCR from 99 fecal samples agreed with each other, while one real-time PCR-positive sample tested negative by iiPCR. Therefore, excellent agreement (k = 0.98) with sensitivity of 98.41% and specificity of 100% in detecting CPV-2 in feces was found between the two methods. In conclusion, the iiPCR system has potential to serve as a useful tool for rapid and accurate PON, molecular detection of CPV-2.


Assuntos
Doenças do Cão/diagnóstico , Doenças do Cão/virologia , Infecções por Parvoviridae/veterinária , Parvovirus Canino/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Animais , Cães , Fezes/virologia , Infecções por Parvoviridae/diagnóstico , Infecções por Parvoviridae/virologia , Sensibilidade e Especificidade , Fatores de Tempo
17.
Phytopathology ; 105(2): 160-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25163013

RESUMO

Agrobacterium tumefaciens transfers a specific DNA fragment from the resident tumor-inducing (Ti) plasmid and effector virulence (Vir) proteins to plant cells during infection. A. tumefaciens VirB1-11 and VirD4 proteins assemble as the type IV secretion system (T4SS), which mediates transfer of the T-DNA and effector Vir protein into plant cells, thus resulting in crown gall disease in plants. Previous studies revealed that an α-crystallin-type, small heat-shock protein (HspL) is a more effective VirB8 chaperone than three other small heat-shock proteins (HspC, HspAT1, and HspAT2). Additionally, HspL contributes to efficient T4SS-mediated DNA transfer and tumorigenesis under room-temperature growth. In this study, we aimed to characterize the impact of HspL on Agrobacterium-mediated transformation efficiency under heat-shock treatment. During heat shock, transient transformation efficiency and VirB8 protein accumulation were lower in the hspL deletion mutant than in the wild type. Overexpression of HspL in A. tumefaciens enhanced the transient transformation efficiency in root explants of both susceptible and recalcitrant Arabidopsis ecotypes. In addition, the reduced transient transformation efficiency during heat stress was recovered by overexpression of HspL in A. tumefaciens. HspL may help maintain VirB8 homeostasis and elevate Agrobacterium-mediated transformation efficiency under both heat-shock and nonheat-shock growth.


Assuntos
Agrobacterium tumefaciens/patogenicidade , Arabidopsis/microbiologia , Proteínas de Choque Térmico/genética , Doenças das Plantas/microbiologia , Fatores de Virulência/genética , Agrobacterium tumefaciens/genética , Agrobacterium tumefaciens/fisiologia , Proteínas de Bactérias/genética , DNA Bacteriano/genética , Regulação Bacteriana da Expressão Gênica , Temperatura Alta , Raízes de Plantas/microbiologia , Tumores de Planta , Plasmídeos/genética , Estresse Fisiológico , Virulência
18.
BMC Vet Res ; 10: 213, 2014 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-25200113

RESUMO

BACKGROUND: Canine distemper virus (CDV) has been associated with outbreaks of canine infectious respiratory disease in shelters and boarding kennel environments. POCKITTM Nucleic Acid Analyzer is a field-deployable device capable of generating automatically interpreted insulated isothermal polymerase chain reaction (iiPCR) results from extracted nucleic acid within one hour. In this study, reverse transcription iiPCR (RT-iiPCR) was developed to facilitate point-of-need diagnosis of CDV infection. RESULTS: Analytical sensitivity (limit of detection 95%) of the established CDV RT-iiPCR was about 11 copies of in vitro transcribed RNA per reaction. CDV RT-iiPCR generated positive signals from CDV, but not Bordetella bronchiseptica, canine parvovirus, canine herpesvirus, canine adenovirus 2, canine influenza virus (subtype H3N8), canine parainfluenza virus, and canine respiratory coronavirus. To evaluate accuracy of the established reaction in canine distemper clinical diagnosis, 110 specimens from dogs, raccoons, and foxes suspected with CDV infection were tested simultaneously by CDV RT-iiPCR and real-time RT-PCR. CDV RT-iiPCR demonstrated excellent sensitivity (100%) and specificity (100%), compared to real-time RT-PCR. CONCLUSIONS: The results indicated an excellent correlation between RT-iiPCR and a reference real time RT-PCR method. Working in a lyophilized format, the established method has great potential to be used for point-of-care diagnosis of canine distemper in animals, especially in resource-limited facilities.


Assuntos
Vírus da Cinomose Canina/isolamento & purificação , Cinomose/virologia , Reação em Cadeia da Polimerase/veterinária , Animais , Cinomose/diagnóstico , Cães , Reação em Cadeia da Polimerase/métodos , RNA Viral/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
19.
J Virol Methods ; 207: 66-72, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24992669

RESUMO

Equine influenza (EI) is an acute, highly contagious viral respiratory disease of equids. Currently, equine influenza virus (EIV) subtype H3N8 continues to be the most important respiratory pathogen of horses in many countries around the world. The need to achieve a rapid diagnosis and to implement effective quarantine and movement restrictions is critical in controlling the spread of EIV. In this study, a novel, inexpensive and user-friendly assay based on an insulated isothermal RT-PCR (iiRT-PCR) method on the POCKIT™, a field-deployable device, was described and validated for point-of-need detection of EIV-H3N8 in clinical samples. The newly established iiRT-PCR assay targeting the EIV HA3 gene was evaluated for its sensitivity using in vitro transcribed (IVT) RNA, as well as ten-fold serial dilutions of RNA extracted from the prototype H3N8 strain A/equine/Miami/1/63. Inclusivity and exclusivity panels were tested for specificity evaluation. Published real-time RT-PCR (rRT-PCR) assays targeting the NP and HA3 genes were used as the reference standards for comparison of RNA extracted from field strains and from nasal swab samples collected from experimentally infected horses, respectively. Limit of detection with a 95% probability (LoD95%) was estimated to be 11copies of IVT RNA. Clinical sensitivity analysis using RNA prepared from serial dilutions of a prototype EIV (Miami 1/63/H3N8) showed that the iiRT-PCR assay was about 100-fold more sensitive than the rRT-PCR assay targeting the NP gene of EIV subtype H3N8. The iiRT-PCR assay identified accurately fifteen EIV H3N8 strains and two canine influenza virus (CIV) H3N8 strains, and did not cross-react with H6N2, H7N7, H1N1 subtypes or any other equine respiratory viral pathogens. Finally, 100% agreement was found between the iiRT-PCR assay and the universal influenza virus type A rRT-PCR assay in detecting the EIV A/equine/Kentucky/7/07 strain in 56 nasal swab samples collected from experimentally inoculated horses. Therefore, the EIV H3N8 subtype specific iiRT-PCR assay along with the portable POCKIT™ Nucleic Acid Analyzer provides a highly reliable, sensitive and specific on-site detection system of both equine and canine influenza viruses.


Assuntos
Vírus da Influenza A Subtipo H3N8/isolamento & purificação , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Medicina Veterinária/instrumentação , Medicina Veterinária/métodos , Animais , Cavalos , Vírus da Influenza A Subtipo H3N8/genética , Infecções por Orthomyxoviridae/diagnóstico , Infecções por Orthomyxoviridae/veterinária , Infecções por Orthomyxoviridae/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
20.
PLoS One ; 9(3): e90545, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625894

RESUMO

Timely pond-side detection of white spot syndrome virus (WSSV) plays a critical role in the implementation of bio-security measures to help minimize economic losses caused by white spot syndrome disease, an important threat to shrimp aquaculture industry worldwide. A portable device, namely POCKIT™, became available recently to complete fluorescent probe-based insulated isothermal PCR (iiPCR), and automatic data detection and interpretation within one hour. Taking advantage of this platform, the IQ Plus™ WSSV Kit with POCKIT system was established to allow simple and easy WSSV detection for on-site users. The assay was first evaluated for its analytical sensitivity and specificity performance. The 95% limit of detection (LOD) of the assay was 17 copies of WSSV genomic DNA per reaction (95% confidence interval [CI], 13 to 24 copies per reaction). The established assay has detection sensitivity similar to that of OIE-registered IQ2000™ WSSV Detection and Protection System with serial dilutions of WSSV-positive Litopenaeus vannamei DNA. No cross-reaction signals were generated from infectious hypodermal and haematopoietic necrosis virus (IHHNV), monodon baculovirus (MBV), and hepatopancreatic parvovirus (HPV) positive samples. Accuracy analysis using 700 L. vannamei of known WSSV infection status shows that the established assayhassensitivity93.5% (95% CI: 90.61-95.56%) and specificity 97% (95% CI: 94.31-98.50%). Furthermore, no discrepancy was found between the two assays when 100 random L. vannamei samples were tested in parallel. Finally, excellent correlation was observed among test results of three batches of reagents with 64 samples analyzed in three different laboratories. Working in a portable device, IQ Plus™ WSSV Kit with POCKIT system allows reliable, sensitive and specific on-site detection of WSSV in L. vannamei.


Assuntos
Penaeidae/virologia , Reação em Cadeia da Polimerase/instrumentação , Viroses/diagnóstico , Viroses/veterinária , Animais , Aquicultura , DNA Viral/isolamento & purificação , Processamento Eletrônico de Dados , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vírus da Síndrome da Mancha Branca 1/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...