Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Heart Lung Transplant ; 34(12): 1604-10, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26163154

RESUMO

BACKGROUND: Right heart failure (RHF) is a serious post-operative complication of left ventricular assist device (LVAD) implantation, with significant morbidity and mortality. Many clinical, hemodynamic and laboratory variables have been shown to have prognostic value for appearance of RHF. We sought to investigate the incidence of new-onset right ventricular dysfunction (RVD) complicating the long-term use of LVADs. METHODS: We retrospectively examined all patients supported with a continuous-flow LVAD for >1 year at our center. RESULTS: Twenty patients (mean age 54 ± 10 years, 95% men, 60% with ischemic cardiomyopathy, left ventricular ejection fraction 22 ± 6%, pulmonary capillary wedge pressure 23.5 ± 7.5 mm Hg, brain natriuretic peptide [BNP] 1,566 ± 1,536 pg/ml, serum creatinine 1.6 ± 0.64 mg/dl, furosemide dose 643 ± 410 mg/day) underwent long-term mechanical support as destination therapy support with a continuous-flow LVAD (HeartMate II) at our center. During follow-up (1,219 ± 692 days), 9 patients (45%) manifested symptoms and signs of RVD (increase in right atrial pressure [RAP], BNP and daily furosemide dose compared with the early post-operative period). In these patients, RAP was increased by 6.6 ± 2.6 mm Hg and BNP by 526 ± 477 pg/ml, whereas furosemide dose increased by 145 ± 119 mg. The mean and median times of RVD onset were 2.3 ± 1.5 and 2.1 years, respectively, after LVAD implantation (range 0.4 to 4.8 years). Four of these patients (44.4%) demonstrated further deterioration of RV function and died 73 ± 106 days (median 25 days, range 9 to 231 days) after first manifestation of RVD. Comparisons of baseline variables regarding medical history and clinical status did not demonstrate significant differences between the patients with or without RVD, including parameters related to RV function at the time of implantation. CONCLUSIONS: Late-onset RVD is a complication of LVAD support, which can manifest several months to years from device implantation. This complication has significant adverse implications with regard to patient outcome. Prognostic factors need to be identified to follow and treat high-risk patients more efficiently.


Assuntos
Coração Auxiliar/efeitos adversos , Disfunção Ventricular Direita/etiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Disfunção Ventricular Direita/epidemiologia
3.
Int J Cardiol ; 192: 3-8, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25981570

RESUMO

BACKGROUND: Right ventricular dysfunction is associated with high morbidity and mortality in candidates for left ventricular assist device (LVAD) implantation or cardiac transplantation. METHODS: We examined the effects of prolonged intra-aortic balloon pump (IABP) support on right ventricular, renal and hepatic functions in patients presenting with end-stage heart failure. RESULTS: Between March 2008 and June 2013, fifteen patients (mean age = 49.5 years; 14 men) with end-stage systolic heart failure (HF), contraindications for any life saving procedure (conventional cardiac surgery, heart transplantation, LVAD implantation) and right ventricular dysfunction were supported with the IABP. The patients remained on IABP support for a mean of 73 ± 50 days (median 72, range of 13-155). We measured the echocardiographic and hemodynamic changes in right ventricular function, and the changes in serum creatinine and bilirubin concentrations before and during IABP support. Mean right atrial pressure decreased from 12.7 ± 6.5 to 3.8 ± 3.3 (P < 0.001) and pulmonary artery pressure decreased from 35.7 ± 10.6 to 25 ± 8.4 mmHg (P = 0.001), while cardiac index increased from 1.5 ± 0.4 to 2.2 ± 0.7 l/m(2)/min (P = 0.003) and right ventricular stroke work index from 485 ± 228 to 688 ± 237 mmHg × ml/m(2) (P = 0.043). Right ventricular end-diastolic diameter decreased from 34.0 ± 6.5 mm to 27.8 ± 6.2 mm (P < 0.001) and tricuspid annular systolic tissue Doppler velocity increased from 9.6 ± 2.4 cm/s to 11.1 ± 2.3 cm/s (P = 0.029). Serum creatinine and bilirubin decreased from 2.1 ± 1.3 to 1.4 ± 0.6 mg/dl and 2.0 ± 1.0 to 0.9 ± 0.5 mg/dl, respectively (P = 0.002 and P < 0.001, respectively). CONCLUSIONS: Prolonged IABP support of patients presenting with end-stage heart failure and right ventricular dysfunction induced significant improvement in right ventricular and peripheral organ function.


Assuntos
Insuficiência Cardíaca/terapia , Balão Intra-Aórtico , Disfunção Ventricular Direita/terapia , Função Ventricular Direita/fisiologia , Remodelação Ventricular/fisiologia , Adulto , Bilirrubina/sangue , Creatinina/sangue , Ecocardiografia , Feminino , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Testes de Função Renal , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Direita/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...