Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 60(7): 1884-90, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23380848

RESUMO

Microultrasound (micro-US), also known as ultrasound biomicroscope, is able to delineate small structures with fine spatial resolution. However, micro-US suffers limited depth of penetration due to significantly large attenuation at high frequencies. Modulated excitation imaging has displayed the capability to improve the penetration depth, while maintaining the spatial resolution. But the effectiveness of this technique in micro-US has not been fully demonstrated. In addition, the current modulated excitation imaging systems for micro-US are designed for specific excitation method, therefore, lack of flexibility, and are typically bulky and expensive. This paper presents the development of a novel system to achieve modulated excitation imaging with high programmability and flexibility to satisfy various micro-US studies. It incorporates a high-voltage arbitrary waveform generator for producing desired excitation waveform, and a programmable imaging receiver implemented by the state-of-the-art electronics and field-programmable gate array. Test results show that the proposed modulated excitation imaging system can acquire up to 20 dB signal-to-noise ratio improvement and 83% increase of penetration depth in contrast to traditional short-pulse imaging method. In vivo experiment on the dorsal skin of a human hand demonstrates good performance of the programmable modulated excitation imaging system.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Microscopia Acústica/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Artigo em Inglês | MEDLINE | ID: mdl-23287923

RESUMO

Micro-ultrasound is an invaluable imaging tool for many clinical and preclinical applications requiring high resolution (approximately several tens of micrometers). Imaging systems for micro-ultrasound, including single-element imaging systems and linear-array imaging systems, have been developed extensively in recent years. Single-element systems are cheaper, but linear-array systems give much better image quality at a higher expense. Annular-array-based systems provide a third alternative, striking a balance between image quality and expense. This paper presents the development of a novel programmable and real-time annular-array imaging platform for micro-ultrasound. It supports multi-channel dynamic beamforming techniques for large-depth-of-field imaging. The major image processing algorithms were achieved by a novel field-programmable gate array technology for high speed and flexibility. Real-time imaging was achieved by fast processing algorithms and high-speed data transfer interface. The platform utilizes a printed circuit board scheme incorporating state-of-the-art electronics for compactness and cost effectiveness. Extensive tests including hardware, algorithms, wire phantom, and tissue mimicking phantom measurements were conducted to demonstrate good performance of the platform. The calculated contrast-to-noise ratio (CNR) of the tissue phantom measurements were higher than 1.2 in the range of 3.8 to 8.7 mm imaging depth. The platform supported more than 25 images per second for real-time image acquisition. The depth-of-field had about 2.5-fold improvement compared to single-element transducer imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microtecnologia/instrumentação , Microtecnologia/métodos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Algoritmos , Desenho de Equipamento , Modelos Biológicos , Imagens de Fantasmas , Transdutores
3.
Artigo em Inglês | MEDLINE | ID: mdl-23143570

RESUMO

Visualization of the blood vessels can provide valuable morphological information for diagnosis and therapy strategies for cardiovascular disease. Intravascular ultrasound (IVUS) is able to delineate internal structures of vessel wall with fine spatial resolution. However, the developed IVUS is insufficient to identify the fibrous cap thickness and tissue composition of atherosclerotic lesions. Novel imaging strategies have been proposed, such as increasing the center frequency of ultrasound or using a modulated excitation technique to improve the accuracy of diagnosis. Dual-mode tomography combining IVUS with optical tomography has also been developed to determine tissue morphology and characteristics. The implementation of these new imaging methods requires an open system that allows users to customize the system for various studies. This paper presents the development of an IVUS system that has open structures to support various imaging strategies. The system design is based on electronic components and printed circuit board, and provides reconfigurable hardware implementation, programmable image processing algorithms, flexible imaging control, and raw RF data acquisition. In addition, the proposed IVUS system utilized a miniaturized ultrasound transducer constructed using PMNPT single crystal for better piezoelectric constant and electromechanical coupling coefficient than traditional lead zirconate titanate (PZT) ceramics. Testing results showed that the IVUS system could offer a minimum detectable signal of 25 µV, allowing a 51 dB dynamic range at 47 dB gain, with a frequency range from 20 to 80 MHz. Finally, phantom imaging, in vitro IVUS vessel imaging, and multimodality imaging with photoacoustics were conducted to demonstrate the performance of the open system.


Assuntos
Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Algoritmos , Animais , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Suínos , Tomografia , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...