Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 11(5): 594-600, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19363054

RESUMO

AIMS: The deleterious effects of right ventricular apex (RVA) pacing may offset the potential benefit of ventricular rate (VR) regularization during atrial fibrillation (AF). Recent studies suggested that right ventricular septal (RVS) pacing may prevent the potential deleterious effects of RVA pacing and enhance the VR regularization (VRR) with ventricular pacing due to closer proximity of the pacing site to the retrograde atrioventricular conduction. METHODS AND RESULTS: We randomized 24 patients with permanent AF and symptomatic bradycardia to undergo RVA (n = 12) or RVS (n = 12) pacing. A VRR algorithm was programmed for all patients at 6-month after implantation. All patients underwent 6 min hall walk (6MHW) to assess exercise capacity at 6, 12, and 24 months, and radionuclide ventriculography to determine left ventricular ejection fraction (LVEF) at 6 and 24 months. Baseline characteristics were comparable in both groups except pacing QRS duration was significantly shorter during RVS pacing than RVA pacing (132 +/- 4 vs. 151 +/- 6 ms, P = 0.012). In both groups, VRR significantly increased the percentage of ventricular pacing and reduced VR variability (P < 0.05) without increasing mean VR (P > 0.05). At 6 months, 6MHW and LVEF were comparable in patients with RVA and RVS pacing (P > 0.05). At 24 months, patients with RVA pacing had significant decreases in LVEF and 6MHW after VRR pacing (P < 0.05), whereas RVS pacing with VRR preserved LVEF and improved 6MHW (P < 0.05). CONCLUSION: In patients with permanent AF, VRR pacing at RVS, but not at RVA, preserves LVEF and provides incremental benefit for exercise capacity.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Tolerância ao Exercício/fisiologia , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Função Ventricular Esquerda/fisiologia , Septo Interventricular/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cintilografia , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Septo Interventricular/diagnóstico por imagem
2.
J Am Coll Cardiol ; 46(12): 2292-7, 2005 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-16360061

RESUMO

OBJECTIVES: The purpose of this research was to investigate the effect of using rate-adaptive pacing and atrioventricular interval (AVI) adaptation on exercise performance during cardiac resynchronization therapy (CRT). BACKGROUND: The potential incremental benefits of using rate-adaptive pacing and AVI adaptation with CRT during exercise have not been studied. METHODS: We studied 20 patients with heart failure, chronotropic incompetence (<85% age-predicted heart rate [AP-HR] and <80% HR reserve), and implanted with CRT. All patients underwent a cardiopulmonary exercise treadmill test using DDD mode with fixed AVI (DDD-OFF), DDD mode with adaptive AVI on (DDD-ON), and DDDR mode with adaptive AVI on (DDDR-ON) to measure metabolic equivalents (METs) and peak oxygen consumption (VO2max). RESULTS: During DDD-OFF mode, not all patients reached 85% AP-HR during exercise, and 55% of patients had <70% AP-HR. Compared to patients with >70% AP-HR, patients with <70% AP-HR had significantly lower baseline HR (66 +/- 3 beats/min vs. 80 +/- 5 beats/min, p = 0.015) and percentage HR reserve (27 +/- 5% vs. 48 +/- 6%, p = 0.006). In patients with <70% AP-HR, DDDR-ON mode increased peak exercise HR, exercise time, METs, and VO2max compared with DDD-OFF and DDD-ON modes (p < 0.05), without a significant difference between DDD-OFF and DDD-ON modes. In contrast, there were no significant differences in peak exercise HR, exercise time, METs, and VO2max among the three pacing modes in patients with >70% AP-HR. The percentage HR changes during exercise positively correlated with exercise time (r = 0.67, p < 0.001), METs (r = 0.56, p < 0.001), and VO2max (r = 0.55, p < 0.001). CONCLUSIONS: In heart failure patients with severe chronotropic incompetence as defined by failure to achieve >70% AP-HR, appropriate use of rate-adaptive pacing with CRT provides incremental benefit on exercise capacity during exercise.


Assuntos
Adaptação Fisiológica , Baixo Débito Cardíaco/fisiopatologia , Baixo Débito Cardíaco/terapia , Estimulação Cardíaca Artificial/métodos , Exercício Físico , Frequência Cardíaca , Idoso , Algoritmos , Nó Atrioventricular/fisiopatologia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
3.
Pacing Clin Electrophysiol ; 28(5): 421-4, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15869674

RESUMO

BACKGROUND: Recent studies have demonstrated that transvenous catheter cryoablation is a safe and effective technique for creating pulmonary veins (PVs) electrical isolation for the treatment of atrial fibrillation (AF). However, the impacts of this procedure on quality-of-life (QoL) have not been evaluated. METHODS AND RESULTS: We studied the effects of PV isolation using transvenous catheter cryoablation on QoL in 46 patients (34 men, mean age: 50 +/- 12 years) with drug-refractory AF. QoL was assessed by Medical Outcomes Study Short Form-36 (SF-36) and Symptom Checklist at baseline and 3-month after cryoablation, and compared with those in a sex-age matched normal control. At 3-month follow-up, 24 of 46 patients (52%) had no recurrence of AF, including 11 patients who were not taking antiarrhythmic drugs. At baseline, patients with AF had significantly lower QoL scores in overall and in 5/8 subscales of SF-36 than the sex-age matched control group (P < 0.05). In patients with successful outcome after cryoablation showed a significant improvement in overall and in 5/8 subscales of SF-36 QoL scores have significantly increased as compared with the baseline (P < 0.05). Furthermore, their QoL scores in overall and in 6/8 subscales of SF-36 were similar to the sex-age matched control group (P > 0.05). The Symptom Checklist also showed significant reduction in both the symptoms frequency scores and symptoms severity scores at 3-month follow-up as compared with baseline (P < 0.05). CONCLUSIONS: Successful PV isolation using transvenous catheter cryoablation is associated with significant reduction in the frequency and severity of AF symptoms and improvement in the general QoL, reaching the levels of normal controls.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Qualidade de Vida , Ablação por Cateter/métodos , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 28 Suppl 1: S242-5, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15683506

RESUMO

Upon standing from a supine position, the normal response is an increase in heart rate to maintain blood pressure (BP). In patients with chronotropic incompetence, heart rate may not increase upon standing, and they may experience orthostatic hypotension (OH). We evaluated a new orthostatic response (OSR) pacing algorithm that uses an accelerometer signal to detect sudden activity following prolonged rest to trigger a 2 minutes increase in pacing rate to 94 bpm. Ten recipients of DDDR pacemakers which contain the OSR compensation algorithm (mean age = 77 +/- 9 years, 8 women) with sick sinus syndrome (n = 6) or atrioventricular block (n = 4) were studied. In all patients BP was measured before and 0.5, 1, 1.5, 2, and 3 minutes after standing at their programmed base rate. A 20 mmHg fall in systolic BP upon standing was observed in five patients (OH patients), while the other five were considered non-OH patients. The measurements were repeated with the OSR algorithm turned on. Mean BP was defined as 1/3 systolic BP + 2/3 diastolic BP. Baseline heart rate was significantly slower in OH patients (62 +/- 2 bpm) than non-OH patients (71 +/- 7 bpm, P < 0.05). In OH patients mean BP increased significantly upon standing (P < 0.05 for all comparisons) with the algorithm ON instead of decreasing with the algorithm OFF, at 1 minute (+3.4 vs -10.3 mmHg), 1.5 minutes (+7.0 vs -4.9 mmHg), 2 minutes (+1.6 vs -6.7 mmHg), and 3 minutes (+2.5 vs -8.5 mmHg). These preliminary results suggest that the OSR algorithm maintains BP upon standing in patients with OH.


Assuntos
Algoritmos , Pressão Sanguínea/fisiologia , Hipotensão Ortostática/fisiopatologia , Marca-Passo Artificial , Postura/fisiologia , Idoso , Feminino , Humanos , Masculino , Decúbito Dorsal
5.
J Am Coll Cardiol ; 40(8): 1451-8, 2002 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-12392836

RESUMO

OBJECTIVES: We sought to evaluate the long-term effects of alternative right ventricular pacing sites on myocardial function and perfusion. BACKGROUND: Previous studies have demonstrated that asynchronous ventricular activation due to right ventricular apical (RVA) pacing alters regional myocardial perfusion and functions. METHODS: We randomized 24 patients with complete atrioventricular block to undergo permanent ventricular stimulation either at the RVA (n = 12) or right ventricular outflow (RVOT) (n = 12). All patients underwent dipyridamole thallium myocardial scintigraphy and radionuclide ventriculography at 6 and 18 months after pacemaker implantation. RESULTS: After pacing, the mean QRS duration was significantly longer during RVA pacing than during RVOT pacing (151 +/- 6 vs. 134 +/- 4 ms, p = 0.03). At six months, the incidence of myocardial perfusion defects (50% vs. 25%) and regional wall motion abnormalities (42% vs. 25%) and the left ventricular ejection fraction (LVEF) (55 +/- 3% vs. 55 +/- 1%) were similar during RVA pacing and RVOT pacing (p > 0.05). However, at 18 months, the incidence of myocardial perfusion defects (83% vs. 33%) and regional wall motion abnormalities (75% vs. 33%) were higher and LVEF (47 +/- 3 vs. 56 +/- 1%) was lower during RVA pacing than during RVOT pacing (all p < 0.05). Patients with RVA pacing had a significant increase in the incidence of myocardial perfusion defects (p < 0.05) and a decrease in LVEF (p < 0.01) between 6 and 18 months, but patients with RVOT pacing did not (p > 0.05). CONCLUSIONS: This study demonstrates that preserved synchronous ventricular activation with RVOT pacing prevents the long-term deleterious effects of RVA pacing on myocardial perfusion and function in patients implanted with a permanent pacemaker.


Assuntos
Estimulação Cardíaca Artificial , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Idoso , Idoso de 80 Anos ou mais , Circulação Coronária , Dipiridamol , Eletrocardiografia , Feminino , Bloqueio Cardíaco/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Estudos Prospectivos , Ventriculografia com Radionuclídeos , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Vasodilatadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...