Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 22(5): 494-501, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18059078

RESUMO

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the determination of roxithromycin in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 2.2 mL 96-deep-well plates. Roxithromycin and the internal standard clarithromycin were extracted from 100 microL of human plasma by LLE, using methyl t-butyl ether as the organic solvent. All liquid transfer steps were performed automatically using robotic liquid handling workstations. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted. Sample analysis was performed by reversed-phase LC-MS/MS, with positive ion electrospray ionization, using multiple-reaction monitoring. The method had a very short chromatographic run time of 1.6 min. The calibration curve was linear for the range of concentrations 50.0-20.0x10(3) ng mL(-1). The proposed method was fully validated and it was proven to be selective, accurate, precise, reproducible and suitable for the determination of roxithromycin in human plasma. Therefore, it was applied to the rapid and reliable determination of roxithromycin in a bioequivalence study after per os administration of 300 mg tablet formulations of roxithromycin.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Roxitromicina/sangue , Espectrometria de Massas em Tandem/métodos , Análise de Variância , Antibacterianos/sangue , Antibacterianos/farmacocinética , Humanos , Reprodutibilidade dos Testes , Roxitromicina/farmacocinética , Equivalência Terapêutica
2.
Biomed Chromatogr ; 21(2): 201-8, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17221909

RESUMO

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for terbinafine quantification in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 2.2 mL 96-deepwell plates. Terbinafine and the internal standard (IS) N-methyl-1-naphthalenemethylamine were extracted from human plasma by LLE, using a mixture of methyl t-butyl ether (MTBE)-hexane (70:30, v/v) as the organic solvent. All liquid transfer steps, including preparation of calibration standards and quality control samples, as well as the addition of the IS, were performed automatically by using robotic liquid handling workstations. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of a reconstitution solution. Sample analysis was performed by reversed-phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The method had a very short sample preparation time and a chromatographic run time of 2.2 min. It was proved to have excellent sensitivity, specificity, accuracy as well as inter- and intraday precision for the quantification of terbinafine in human plasma. The calibration curve was linear for the range of concentrations 5.0-2000.0 ng/mL. The proposed method was applied to the rapid and reliable determination of terbinafine in a bioequivalence study after per os administration of 250 mg tablet formulations of terbinafine.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Naftalenos/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Automação , Estabilidade de Medicamentos , Humanos , Reprodutibilidade dos Testes , Terbinafina , Equivalência Terapêutica
3.
J Pharm Biomed Anal ; 43(3): 1151-5, 2007 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-17045443

RESUMO

In the current study, a semi-automated, 96-well format, solid-phase extraction (SPE), analytical column-switching method for alendronate determination in human urine is developed, validated and applied to a bioequivalence study. The current protocol was a substantial improvement of an existing classical method. A robotic liquid handling system was employed to simplify and reduce the time of sample preparation procedure. Automated SPE was carried out using a 96-well cartridge plate and a vacuum control system. Urine samples were determined by applying a column-switching protocol with fluorescence detection. Analysis time, due to the column-switching procedure, was about half of the conventional LC approach (11.5 min instead of 21 min). The method application required the determination of alendronate in urine samples obtained from 96 healthy volunteers as part of a bioequivalence study of two 70 mg alendronate sodium tablets. All major pharmacokinetic parameters of the bioequivalence study were estimated and reported.


Assuntos
Alendronato/urina , Conservadores da Densidade Óssea/urina , Alendronato/farmacocinética , Autoanálise , Conservadores da Densidade Óssea/farmacocinética , Calibragem , Química Farmacêutica , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Masculino , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Fluorescência , Equivalência Terapêutica
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 836(1-2): 79-82, 2006 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-16581316

RESUMO

A rapid and sensitive LC-MS/MS method for the quantification of ondansetron was developed and validated. The plasma samples were treated by a semi-automated liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Ondansetron and the internal standard (IS) granisetron were analyzed by combined reversed phase LC-MS/MS, with positive ion electrospray ionization, using multiple reactions monitoring (MRM). The statistical evaluation for this method reveals excellent linearity, accuracy and precision values for the range of concentrations 0.25-40.0 ng/mL. The proposed method enabled the reliable determination of ondansetron in bioequivalence studies after per os administration of a 4 or 8 mg tablet.


Assuntos
Cromatografia Líquida/métodos , Ondansetron/sangue , Antagonistas da Serotonina/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Anal Bioanal Chem ; 384(1): 199-207, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16333603

RESUMO

A semi-automated liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous quantification of the antifungal drug itraconazole (ITZ) and its coactive metabolite hydroxyitraconazole (OH-ITZ) in human plasma. The plasma samples underwent liquid-liquid extraction (LLE) in 2.2 mL 96 deepwell plates. ITZ, OH-ITZ and the internal standard (IS) R51012 were extracted from plasma, using a mixture of acetonitrile (ACN) and methyl t-butyl ether (MTBE) as the organic solvent. This specific mixture, due to its composition, had a significant impact on the performance of the assay. All liquid transfer steps, including preparation of calibration standards and quality control samples as well as the addition of the IS, were performed automatically using robotic liquid handling workstations for parallel sample processing. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analytes and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by combined reversed phase LC/MS/MS, with positive ion electrospray ionization and a TurboIonSpray interface, using multiple reactions monitoring (MRM). The method was shown to be sensitive and specific to both ITZ and OH-ITZ, it revealed excellent linearity for the range of concentrations 2-500 ng mL(-1) for ITZ and 4-1000 ng mL(-1) for OH-ITZ, it was very accurate and it gave very good inter- and intra-day precisions. The proposed high-throughput method was employed in a bioequivalence study after per os administration of two 100 mg tablets of ITZ, and it allowed this study to be completed in under four days.


Assuntos
Cromatografia Líquida/métodos , Itraconazol/sangue , Itraconazol/química , Espectrometria de Massas em Tandem/métodos , Humanos , Hidroxilação
6.
Rapid Commun Mass Spectrom ; 19(14): 2055-61, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15988714

RESUMO

A semi-automated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of glimepiride in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Glimepiride and the internal standard (IS) glibenclamide were extracted from human plasma by LLE, using a mixture of ethyl acetate/diethyl ether 50:50 (v/v) as the organic solvent. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analyte and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by reversed-phase LC/MS/MS with positive ion electrospray ionization, using multiple reaction monitoring. The method proved to be sensitive and specific for both drugs, and statistical evaluation revealed excellent linearity for the range of concentrations 2.0-500.0 ng/mL with very good accuracy and inter- and intra-day precisions. The proposed method enabled the rapid and reliable determination of glimepiride in pharmacokinetic or bioequivalence studies after per os administration of a 3 or 4 mg tablet of glimepiride.


Assuntos
Cromatografia Líquida/métodos , Hipoglicemiantes/análise , Espectrometria de Massas/métodos , Compostos de Sulfonilureia/análise , Acetatos , Cromatografia Líquida/instrumentação , Éter , Humanos , Hipoglicemiantes/sangue , Hipoglicemiantes/farmacocinética , Espectrometria de Massas/instrumentação , Solventes , Compostos de Sulfonilureia/sangue , Compostos de Sulfonilureia/farmacocinética
SELEÇÃO DE REFERÊNCIAS