Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Kyobu Geka ; 76(9): 699-702, 2023 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-37735728

RESUMO

A 68-year-old woman with immunosuppressive state following chemotherapy for cancer of unknown primary origin developed infective endocarditis due to methicillin-resistant Staphylococcus aureus (MRSA). Echocardiography showed shunt blood flow from the aortic annular abscess into the left atrium, which indicated infection of the intervalvular fibrosa (IVF). She underwent Commando procedure owing to progression of heart failure. The aortic valve, IVF, and anterior leaflet of the mitral valve were resected. The mitral valve was replaced with a bioprosthesis, and a bovine pericardial patch was used to reconstruct the IVF and left atrial roof. Bentall procedure was performed because the infection extended to the sinus of Valsalva, and the ascending aorta was 49 mm in diameter. She had no serious postoperative complications and is currently being followed up at the outpatient clinic. Because infection in these patients are potentially fatal, we believe Commando procedure is effective in spite of high early mortality rate.


Assuntos
Endocardite Bacteriana , Endocardite , Staphylococcus aureus Resistente à Meticilina , Feminino , Humanos , Animais , Bovinos , Idoso , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Endocardite/diagnóstico por imagem , Endocardite/cirurgia , Valva Mitral , Abscesso
2.
JTCVS Tech ; 15: 87-94, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36276697

RESUMO

Objectives: To explore the impact of the no-touch harvesting technique on the vessel diameter of saphenous vein grafts. Methods: This retrospective, single-center study enrolled 166 patients who underwent isolated coronary artery bypass grafting using saphenous vein grafts. Saphenous vein grafts were harvested conventionally in 83 patients (conventional group) and using the no-touch technique in 83 patients (no-touch group). We analyzed graft patency and the vessel diameters of saphenous vein grafts in the pre- and postoperative states. The diameter mismatch between the saphenous vein grafts and the coronary artery at the anastomotic site was also measured; preoperative diameter was measured using ultrasound imaging, and the postoperative diameter was measured using electrocardiogram-gated enhanced computed tomography. Results: A total of 135 saphenous vein grafts (66 and 69 grafts in the conventional and no-touch groups, respectively) were evaluated for postoperative patency. Graft patency was equivalent in the 2 groups (conventional, 96.9% vs no-touch, 100%; P = .24). A detailed evaluation was performed in 109 saphenous vein grafts (52 and 57 grafts in the conventional and no-touch groups, respectively). Saphenous vein graft diameter was significantly distended in the conventional group (preoperative, 2.6 ± 0.7 mm vs postoperative, 3.4 ± 0.5 mm; P < .0001). However, saphenous vein graft diameter did not change in the no-touch group (preoperative, 2.9 ± 0.4 mm vs postoperative 2.8 ± 0.4 mm, P = .33). The diameter mismatch was significantly smaller in the no-touch group (conventional 1.4 ± 0.6 mm vs no-touch 1.0 ± 0.4 mm, P < .0001). Conclusions: The no-touch technique avoids the expansion of graft diameter and diameter mismatch between the saphenous vein grafts and coronary artery.

3.
Artigo em Inglês | MEDLINE | ID: mdl-35758613

RESUMO

OBJECTIVES: The adventitial inversion technique is used widely for aortic reconstruction for acute type A aortic dissection, as it easily controls the bleeding at anastomotic sites and closes the patent false lumen. However, this technique for arch vessel reconstruction has not been previously reported. Therefore, we applied the adventitial inversion technique for dissected arch vessel reconstruction to close the patent false lumen. METHODS: Among 57 consecutive patients who underwent emergency surgical treatment for acute type A aortic dissection from July 2006 to July 2012, the adventitial inversion technique for the dissected arch vessels was performed in 26 patients (42 arch vessel stumps). The patency and morphologic change of the false lumen of the arch vessels were evaluated using contrast-enhanced computed tomography. RESULTS: Overall, 2 hospital deaths were recorded, and the hospital mortality rate was 4%. No postoperative cerebral strokes and reoperations due to bleeding occurred. Follow-up by contrast-enhanced computed tomography was completed in 24 patients (37 stumps) with a mean duration of 99 ± 35 months. The postoperative closure rate of the false lumen after adventitial inversion was 86%, which was higher than when adventitial inversion was not used. No adverse events including stroke occurred during follow-up period. CONCLUSIONS: This technique facilitates the closure of the false lumen of dissected arch vessels and might improve clinical outcomes.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Túnica Adventícia/diagnóstico por imagem , Túnica Adventícia/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Mortalidade Hospitalar , Humanos , Estudos Retrospectivos , Stents , Resultado do Tratamento
4.
J Card Surg ; 37(9): 2600-2606, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35771215

RESUMO

BACKGROUND AND AIMS: The optimal procedure for reconstructing the dissected aortic stump for acute type A dissection remains controversial. We routinely used the intimal-protected adventitial inversion technique (iPAIT), a modified adventitial inversion technique, to protect the fragile intima by inserting a graft and assessed the safety and efficacy of this technique. METHODS: Between August 2008 and April 2020, 146 consecutive patients with acute type A dissections underwent thoracic aortic surgery in our hospital. Extended total aortic arch replacement was performed in 119 patients (81.5%). Sixty-nine patients underwent treatment for distal aortic anastomosis with the iPAIT. To compare the iPAIT to a historical control, we assessed 69 iPAIT patients and 25 patients who underwent total arch replacement using gelatin-resorcinol-formaldehyde (GRF) glue. RESULTS: Hospital mortality was 2.9% in the iPAIT group and 8.0% in the GRF group. Perioperative characteristics were similar between the two groups. However, postoperative computed tomography revealed that the obliteration rate was significantly higher in the iPAIT group (60/66, 90.9%) than in the GRF group (15/23, 65.2%) (p = .01), not including the patients who had died or developed severe renal dysfunction. The 8-year aortic event-free survival rate in the iPAIT group (81.3%) was significantly higher than that in the GRF group (47.4%). CONCLUSIONS: The use of this technique for acute type A dissections resulted in a low mortality rate and demonstrated promising midterm survival and may accelerate the obliteration of a patent false lumen and prevent late aortic events.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Doença Aguda , Anastomose Cirúrgica/métodos , Dissecção Aórtica/etiologia , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Espessura Intima-Media Carotídea , Humanos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-35257176

RESUMO

OBJECTIVES: To evaluate the feasibility of open chest management with our modified negative pressure wound therapy immediately after cardiac surgery as a therapy for atypical tamponade. METHODS: Open chest with modified negative pressure wound therapy was performed immediately after cardiac surgery. The surface of the heart and the vessels were covered with non-adherent siliconized gauze. The sternal halves were stented using edge-cut disposable syringes to maintain a larger mediastinal cavity. Approximately 45 mm of distance was kept between the sternal edges. A trimmed sterile polyvinyl foam sponge was inserted into the mediastinum, the entire wound was sealed and negative pressure (-50 to -75 mmHg) was applied using a suction generator. Delayed chest closure was performed in a standard manner once the haemodynamic status was stabilizsed. RESULTS: The mortality rate was 3/15 (20%) patients. Deep sternal wound infection occurred in 1/15 (6.7%) patients. Five patients were extubated during the open chest management. Sternal closure was delayed for median of 3 days after the initial surgery. There was no incidence of bleeding complications or need for additional haemostatic procedures. CONCLUSIONS: Negative pressure wound therapy performed immediately after cardiac surgery was feasible in our small number of patients. CLINICAL REGISTRATION NUMBER: Study ID: 2020-149.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tratamento de Ferimentos com Pressão Negativa , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Viabilidade , Humanos , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Esterno/cirurgia , Infecção da Ferida Cirúrgica/epidemiologia
6.
Kyobu Geka ; 75(2): 137-141, 2022 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-35249091

RESUMO

A 65-year-old woman was transported to our hospital by ambulance because of severe dyspnea. She had had a subcutaneous tumor on her anterior chest since her childhood. Coronary angiography revealed three vessel disease with significant stenosis in the left main trunk. Excision of anterior chest tumor, 70×60×50 mm in size, was performed before coronary artery bypass grafting( CABG). It was a unilocular cyst adhering to the sternum, and was composed of ciliated epitheliums, goblet cells and smooth muscle cells. Based upon the existence of smooth muscle cells, the tumor was diagnosed as bronchogenic cyst. CABG was performed through mid-sternum about two months after the tumor excision, and the postoperative course was uneventful.


Assuntos
Cisto Broncogênico , Idoso , Cisto Broncogênico/diagnóstico por imagem , Cisto Broncogênico/cirurgia , Criança , Angiografia Coronária , Ponte de Artéria Coronária , Feminino , Humanos
7.
J Am Heart Assoc ; 11(3): e020637, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35043661

RESUMO

Background Saphenous vein grafts (SVGs) are broadly used in coronary artery bypass grafting despite their inferior patency compared with arterial grafts. Recently, the no-touch technique (NT), in which an SVG is harvested with a pedicle of perivascular adipose tissue (PVAT) without conduit distension, was shown to improve long-term patency compared with conventional preparation (CV), wherein outer tissue is removed with distension. The NT was also reportedly associated with reduced atherosclerosis. Although endothelial damage provoked by conventional distension may underlie poor patency when CV is performed, the precise mechanisms underlying the salutary effects of the NT have been unclear. Methods and Results Residual SVGs prepared with CV (CV-SVGs) or NT (NT-SVGs) were obtained during coronary artery bypass grafting. Nitric oxide (NO2-/NO3- (NOx)) levels after 24 hours of tissue culture were quantified. The protein expression and localization were analyzed. The isometric force of SVG strips was measured. NT-SVGs showed superior NOx production to CV-SVGs. PVAT generated the majority of NOx in NT-SVGs. PVAT highly expressed arginosuccinate synthase 1, a rate-limiting enzyme in the molecular circuit for NO synthesis, thereby continuously providing the substrate for NO. A substantial level of endothelial NO synthase was also expressed in PVAT. Pharmacological inhibition of arginosuccinate synthase 1 or endothelial NO synthase significantly suppressed the NOx production in NT-SVGs. PVAT induced vasorelaxation through NO production, even in the endothelium-denuded SVG strips. Conclusions Preserving PVAT was predominantly involved in the superior NOx production in NT-SVGs. Since NO plays crucial roles in suppressing atherosclerosis, this mechanism may greatly contribute to the excellent patency in NT-SVGs.


Assuntos
Aterosclerose , Veia Safena , Tecido Adiposo , Aterosclerose/metabolismo , Dilatação Patológica , Humanos , Óxido Nítrico/metabolismo , Veia Safena/transplante , Grau de Desobstrução Vascular
8.
J Card Surg ; 37(12): 5027-5033, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36595966

RESUMO

BACKGROUND AND AIM OF THE STUDY: To assess the validity and long-term outcomes of direct bilateral axillary arterial cannulation for acute type A aortic dissection. METHODS: Between 2003 and 2020, 208 consecutive patients with acute type A aortic dissection underwent emergency surgical repair. Cardiopulmonary bypass was attempted to establish direct bilateral axillary arterial cannulation and bicaval drainage. Antegrade selective cerebral perfusion was established by axillary perfusion and direct cannulation of the left common carotid artery. RESULTS: Ascending aortic, partial arch, and extended total aortic arch replacement were performed in 50 (24.0%), 7 (3.4%), and 151 (72.6%) patients, respectively. Aortic root surgery and coronary artery bypass grafting were performed concomitantly in 23 and seven patients, respectively. Cardiopulmonary bypass was attempted only through bilateral axillary cannulation in all patients but was successful in 13 (6.3%) patients without bilateral axillary cannulation. No postoperative complications occurred related to this technique. There were seven hospital deaths (early mortality rate, 3.4%). Five patients had postoperative reoperation for bleeding, and nine (4.3%) were transferred to other hospitals due to postoperative permanent cerebral infarction, particularly two with arm ischemia. The 10-year survival rate of patients who underwent emergency surgical repair with this technique was 71.4%. CONCLUSIONS: Direct bilateral axillary arterial cannulation followed by selective cerebral perfusion was successful in 93.7% of patients and this may be an optimal solution for providing stable outcomes after emergency surgery for acute type A aortic dissection. However, we experienced two complications of arm ischemia, attention should be paid to potential arm ischemia.


Assuntos
Dissecção Aórtica , Artéria Axilar , Humanos , Resultado do Tratamento , Dissecção Aórtica/cirurgia , Cateterismo , Aorta/cirurgia , Ponte Cardiopulmonar/métodos
9.
J Card Surg ; 36(1): 62-68, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33124064

RESUMO

BACKGROUND: Computed tomography (CT) is a useful tool for the identification of calcified lesions in the aorta. However, no quantitative evaluation has been established to assess the applicability of simple anastomosis preoperatively. We conducted this retrospective study to establish a reference range of maximal CT attenuation values for application of simple anastomosis. METHODS: A total of 122 consecutive patients underwent replacement of the thoracic aorta between 2007 and 2011, excluding those with acute aortic dissection. The patients were divided into two groups: those who underwent simple anastomosis (simple group: n = 105), and those who required endarterectomy before anastomosis (manipulation group: n = 17). The maximal CT attenuation values at the anastomosis site were calculated by imaging software. RESULTS: The mean maximal CT attenuation values (Hounsfield unit [HU]) was significantly higher in the manipulation group (638.1 ± 269.5 [166-1304]) than in the simple group (94.7 ± 171.5 [0-790]; p < .0001). The maximal CT attenuation values enabled us to predict the simple anastomosis with the area under the receiver operating characteristic curve of 0.96 (p < .0001). The cut-off value was 325 HU (sensitivity 94.1%, specificity 81.7%). The 10-year survival rate was significantly lower in the manipulation group (11.8%) than in the simple group (43.2%). In the multivariate analysis, age (hazard ratio [HR]: 1.073), hypertension (HR: 2.382), and maximal CT attenuation values (HR: 1.001) were independently associated with long-term mortality. CONCLUSIONS: Preoperative evaluation of the maximal CT attenuation values is a useful tool in predicting whether simple anastomosis is applicable or not. Maximal CT attenuation values is a risk factor for long-term mortality.


Assuntos
Doenças da Aorta , Tomografia Computadorizada por Raios X , Aorta , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Humanos , Curva ROC , Estudos Retrospectivos
10.
Gen Thorac Cardiovasc Surg ; 68(12): 1503-1505, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32200521

RESUMO

A thoracic aortic thrombus is rare. The causes of this condition and the feasible options for its treatment remain controversial. Preventing embolic complications are the most important for the management of thoracic aortic thrombi. Herein, we report a case of a giant protruding thrombus in the thoracic aorta. We suggest total arch replacement (TAR) using an open stent graft (OSG) as a favorable management technique for thoracic aortic thrombi. We also recommend bilateral axillary artery cannulation to prevent cerebral infarction.


Assuntos
Aneurisma da Aorta Torácica , Aterosclerose , Implante de Prótese Vascular , Trombose , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Humanos , Stents , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...