Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol Case Rep ; 34: 102032, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38464501

RESUMO

Purpose: To describe the mechanism of progressive hyperopia and its management in the long-term course of traumatic cataract with a posterior capsule tear (PCT) following blunt ocular trauma. Observation: A 37-year-old woman presented with blurry vision and photophobia after being hit in the right eye by a slipper. She was found to have PCT with the formation of a traumatic cataract with emmetropia (0 diopters [D]). Three years after the injury, a broader hyperopic change of +8.0 D was found in the patient at her first visit to our clinic. Optical coherence tomography (OCT) analysis of the anterior segment of the eye revealed damage to the posterior capsule and cataracts due to disorganization of the lens fibers and liquefaction of the lens. Femtosecond laser-associated cataract surgery was performed for anterior capsulotomy and segmentation of the nucleus without further enlargement of the PCT, facilitating the placement of a capsular tension ring segment and a multifocal intra ocular lens (IOL) in the capsular bag. At 1-month post-operation, her uncorrected visual acuity was 20/20 in the right eye, with a well-centered IOL. Conclusions and Importance: Isolated PCT due to blunt trauma is rare, and there have been no reports of progressive hyperopia after three years of follow-up. In such cases, the lens may liquefy, resulting in decreased refraction and significant hyperopia.

2.
J Glaucoma ; 32(2): 107-116, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36223327

RESUMO

PRCIS: Trabeculectomy using the Tenon advancement technique with a fornix-based (FB) conjunctival flap showed avascular bleb formation less frequently and had a significantly lower risk of developing bleb-related infections than trabeculectomy with a limbus-based conjunctival flap. PURPOSE: To determine whether the Tenon advancement technique for trabeculectomy with a FB conjunctival flap is effective in preventing bleb-related infections. MATERIALS AND METHODS: This was a single-center, nonrandomized retrospective cohort study of 998 eyes from 854 patients with glaucoma who underwent trabeculectomy with mitomycin C. Trabeculectomy procedures were categorized into 3 groups: limbus-based (LB, 296 eyes), FB without Tenon advancement (FBTA-, 167 eyes), and FB with Tenon advancement (FBTA+, 535 eyes). The cumulative incidence of bleb-related infections and the rate of surgical success during the 5-year postoperative follow-up period were analyzed using Kaplan-Meier survival analysis and Cox proportional hazards models. Intraocular pressure (IOP) reduction of <20% from baseline or additional glaucoma surgeries was deemed a surgical failure. Surgical success with or without IOP-lowering medications was evaluated according to different IOP criteria. RESULTS: Ten eyes developed bleb-related infections (8 eyes in the LB group and 1 eye in both the FBTA- and FBTA+ groups each). The cumulative probability of bleb-related infections in the LB, FBTA-, and FBTA+ groups was 4.8±1.7% (± standard error), 0.8±0.8%, and 0.3±0.3%, respectively. The FBTA+ group had a significantly lower risk of bleb-related infections than the LB group (hazard ratio, 0.06; 95% confidence interval, 0.01 to 0.39; P =0.009). The FBTA+ group did not have a higher risk of surgical failure. CONCLUSION: The Tenon advancement technique for trabeculectomy using an FB conjunctival flap may be effective in preventing bleb-related infections without compromising surgical success.


Assuntos
Glaucoma , Hipotensão Ocular , Trabeculectomia , Humanos , Glaucoma/tratamento farmacológico , Pressão Intraocular , Mitomicina/uso terapêutico , Hipotensão Ocular/cirurgia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Trabeculectomia/métodos
3.
Transl Vis Sci Technol ; 11(10): 18, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36223126

RESUMO

Purpose: To investigate the association of diurnal blood pressure (BP) and other factors with the intraocular pressure (IOP)-related 24-hour contact lens sensor (CLS) profile of patients with untreated glaucoma. Methods: The prospective study included 82 patients with untreated normal-tension glaucoma. CLS measurements and ambulatory BP monitoring were performed simultaneously for 24 hours. The association between the mean arterial pressure (MAP) and CLS profile was examined for the daytime and nocturnal periods using linear regression analysis. The associations between other factors and the CLS profile were also examined. Results: Multivariate analysis of data from 63 eligible patients showed that higher average MAPs were significantly associated with larger average nocturnal CLS values (ß coefficient = 0.273; P = 0.023); a larger increase in the last CLS value (ß coefficient = 0.366; P = 0.003); larger standard deviations (SDs) of CLS values for the daytime, nocturnal, and 24-hour periods (ß coefficient = 0.407, 0.293, and 0.375; P < 0.001, P = 0.032 and 0.002, respectively); and higher average ocular pulse frequencies for the daytime, nocturnal, and 24-hour periods (ß coefficient = 0.268, 0.380, and 0.403; P = 0.029, 0.002, and 0.001, respectively). Thicker subfoveal choroids and shorter axial length were significantly associated with larger SDs and larger average CLS values, respectively. Smaller anterior chamber volume and lower corneal hysteresis were associated with larger SDs or larger average ocular pulse amplitude. Conclusions: Ambulatory BP and several ocular parameters were significantly associated with various parameters of the 24-hour CLS profile. Translational Relevance: Ambulatory BP and ocular parameters may be modifiers of the 24-hour IOP-related profile of CLS.


Assuntos
Lentes de Contato , Glaucoma , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial , Ritmo Circadiano/fisiologia , Córnea , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Estudos Prospectivos
4.
J Glaucoma ; 31(11): 891-897, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35980846

RESUMO

PRCIS: Corneal hysteresis in both patients with untreated open angle glaucoma and normal individuals demonstrated significant diurnal variation independent of confounding factors and was higher in the nighttime than in the daytime. PURPOSE: To investigate diurnal variations in corneal hysteresis (CH) in patients with untreated primary open angle glaucoma (POAG) and normal individuals by using an ocular response analyzer. MATERIALS AND METHODS: This prospective study included 72 eyes of 53 patients with untreated POAG and 53 eyes of 47 normal individuals. Intraocular pressure (IOP) and CH were measured using Goldmann applanation tonometry (GAT) and ocular response analyzer, respectively, every 3 hours from 9:00 to 24:00. Mixed-effects models were used to determine factors associated with CH values and CH amplitude (maximum values minus minimum values) and to examine the diurnal variations in GAT IOP and CH in each group. Significant differences between time points were defined as significant variations. RESULTS: The diurnal average GAT IOP and CH in patients with POAG were significantly higher and lower than those in normal individuals ( P =0.001, 0.002). In the multivariate analysis, the larger central corneal thickness was associated with larger CH values in POAG and normal eyes (both P <0.001). A larger amplitude of GAT IOP was significantly associated with a larger CH amplitude in POAG and normal eyes ( P =0.010, 0.013). CH, in both groups, showed similar significant diurnal variation and was higher in the nighttime than in the daytime, even after adjusting for confounding factors, while IOP showed an antiphase pattern. CONCLUSION: CH in both untreated POAG patients and normal participants demonstrated similar diurnal variations, that is, higher at night, independent of confounding factors. These findings suggest that viscoelastic properties of the cornea may fluctuate diurnally independent of IOP.


Assuntos
Glaucoma de Ângulo Aberto , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular , Estudos Prospectivos , Campos Visuais , Tonometria Ocular , Córnea/fisiologia
5.
Br J Neurosurg ; : 1-5, 2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35015601

RESUMO

Large or giant paraclinoid aneurysms typically have good indication for flow diverter (FD) treatment. Here, we report a very rare case of a patient with an unruptured supraclinoid large aneurysm who underwent FD deployment with coil embolisation that resulted in delayed visual field defect (VFD) and hydrocephalus. A 75-year-old woman with a large right supraclinoid aneurysm presented with severe hemianopia in the right eye. She underwent FD deployment with coil embolisation of the aneurysm. However, permanent left visual field loss occurred four months after surgery. Magnetic resonance imaging (MRI) showed severe oedema surrounding the aneurysm along the optic tract. Inflammation led to postoperative hydrocephalus, requiring ventriculoperitoneal shunt placement. To the best of our knowledge, this is the first report of both a delayed VFD and hydrocephalus following FD treatment. In cases of FD treatment with coil embolisation for large paraclinoid aneurysms, clinicians should keep in mind that postoperative visual impairment or/and hydrocephalus may occur.

6.
Exp Eye Res ; 203: 108420, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33359512

RESUMO

PURPOSE: For research on circadian intraocular pressure (IOP), rebound tonometers are widely used with or without general anesthesia as a non-invasive approach to obtain IOP values. However, whether general anesthesia such as inhalation anesthesia with isoflurane affects the circadian rhythm of IOP and in turn IOP measurements is currently unclear. As such, data reporting IOP values obtained under general anesthesia should be interpreted with caution. The purpose of this study was to evaluate how general anesthesia with isoflurane inhalation affects the circadian rhythm of IOP. METHODS: C57Bl/6J strain mice maintained using a 12h:12h light/dark cycle (lights on and off at ZT0 and ZT12, respectively) were used. IOPs were measured using a rebound tonometer (Icare TonoLab) before and 3, 5, 10, 15, and 30 min after initiating anesthesia in both light and dark phases (ZT 2-6 and ZT 14-18, respectively). Awake IOPs and IOPs at 3 and 5 min after anesthesia initiation were also obtained at ZT5, 8, 11, 14, 17, and 20 to assess IOP diurnal curves under gas anesthesia. RESULTS: IOP values gradually decreased after anesthesia initiation in both light and dark phases (P < 0.001) and there was no interaction between light/dark phase and anesthesia time (P = 0.88). There was a slight, but not significant, reduction in IOP 3 min after initiating anesthesia (P = 0.23), and significant decreases in IOP occurred at subsequent timepoints (P ≤ 0.001). Both awake and anesthetized mice showed a robust IOP rhythm that reached a peak and trough in the dark and light phase, respectively. Awake IOP levels did not significantly differ from those for anesthetized mice at 3 min after anesthesia initiation at all time points (P ≥ 0.07). CONCLUSIONS: Both awake and anesthetized mice demonstrated a robust circadian rhythm for IOP. Murine IOP showed similar gradual decreases under inhalation anesthesia with isoflurane in both the light and dark phases. IOPs measured using a rebound tonometer within 3 min of initiating isoflurane anesthesia were comparable to awake IOPs, and thus may be useful to monitor the circadian rhythm of IOP in mice.


Assuntos
Anestésicos Inalatórios/farmacologia , Ritmo Circadiano/efeitos dos fármacos , Pressão Intraocular/efeitos dos fármacos , Isoflurano/farmacologia , Anestesia por Inalação , Animais , Feminino , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fotoperíodo , Tonometria Ocular
7.
Eye (Lond) ; 35(3): 919-928, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32467638

RESUMO

BACKGROUND/OBJECTIVES: To identify risk factors for glaucoma-related central visual field (VF) deterioration after vitrectomy with internal limiting membrane (ILM) peeling for epiretinal membrane (ERM). SUBJECTS/METHODS: A prospective cohort study consisting of cases with or without glaucoma (33 eyes of 33 patients in each group) who underwent vitrectomy with ILM peeling for ERM. Humphrey 10-2 VFs and ganglion cell complex (GCC) thickness were measured at baseline and about 3, 6, and 12 months postoperatively. Longitudinal changes in VF indices and factors associated with their postoperative changes were investigated using mixed-effects models, as was sectorwise total deviation (TD) analysis using six sectors consisting of outer/inner arcuate and cecocentral sectors in each hemifield. RESULTS: VF mean deviation significantly deteriorated postoperatively only in the glaucoma group (P < 0.001). Older age, longer axial length, preoperative worse mean deviation, and thinner GCC were significant risk factors for postoperative deterioration (coefficient ± standard errors: -0.139 ± 0.067, -0.740 ± 0.241, 0.16 ± 0.07, 0.050 ± 0.020; P = 0.038, P = 0.002, P = 0.024, P = 0.012, respectively). Sectorwise analysis revealed that TD in the superior/inferior outer arcuate sectors significantly deteriorated only in the glaucoma group. Preoperative worse TD and thinner GCC were significant risk factors for deterioration in the superior outer arcuate sector (0.65 ± 0.11, 0.08 ± 0.03; P < 0.001, P = 0.042, respectively). CONCLUSIONS: Central VF deterioration, especially in the outer arcuate sectors, found to be glaucoma-related changes after vitrectomy with ILM peeling for ERM. Preoperative worse VF and thinner GCC were identified as risk factors for postoperative VF deterioration.


Assuntos
Membrana Epirretiniana , Glaucoma , Idoso , Membrana Basal , Membrana Epirretiniana/cirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Tomografia de Coerência Óptica , Acuidade Visual , Campos Visuais , Vitrectomia
8.
Acta Ophthalmol ; 98(8): e1017-e1023, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32339402

RESUMO

PURPOSE: To evaluate the use of a 24-hr ocular dimensional profile recorded with a contact lens sensor (CLS) combined with a single tonometric intraocular pressure (IOP) reading to indicate the potential for exceeding the diagnostic threshold for normal tension glaucoma (NTG) in Japanese patients. METHODS: Intraocular pressure (IOP) of untreated Japanese NTG patients was measured with tonometry every 3 hr from 9:00 to 24:00. The subsequent day a 24-hr CLS (SENSIMED Triggerfish, Sensimed AG, Lausanne, Switzerland) profile was recorded on the same eye. Patients initially diagnosed as NTG were reclassified as NTG when the measured IOP values were consistently <20 mmHg or as primary open-angle glaucoma (POAG) when IOP was ≥20 mmHg in at least 1 measurement. For each patient and each IOP time-point, IOP values were combined with information provided by the CLS profile ('classifier') to indicate the potential for exceeding the diagnostic threshold value. Statistical analyses were performed for each classifier. RESULTS: A total of 65 patients, 28 males and 37 females (mean ages: 50.8 ± 14.6 years and 52.6 ± 10.2 years, respectively), were analysed. Following IOP diurnal measurement, five patients (7.7%) were reclassified as POAG. Two classifiers (15:00 CLS and 18:00 CLS) showed high sensitivity and negative predictive value (100%), identifying all the POAG patients. CONCLUSION: Contact lens sensor information can be used in conjunction with a single tonometric reading to determine patients' potential of having IOP levels exceeding the diagnostic threshold within a 24-hr period, without the need to perform a 24-hr tonometric curve. This would allow clinicians to identify POAG patients who may otherwise be eventually misclassified as NTG.


Assuntos
Ritmo Circadiano/fisiologia , Lentes de Contato , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Adulto , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
9.
Invest Ophthalmol Vis Sci ; 59(13): 5641-5647, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30481281

RESUMO

Purpose: Intraocular pressure (IOP) fluctuates with a robust circadian rhythm, which is synchronized to organismal rhythmicity through the master circadian clock located in the suprachiasmatic nuclei. The mechanisms maintaining circadian synchrony between the suprachiasmatic nuclei and IOP rhythms are presently unknown. The purpose of this study was to evaluate the necessity and sufficiency of adrenal and glucocorticoid function for the entrainment of iris-ciliary body (iris-CB) and IOP circadian rhythms in mice. Methods: Iris-CB complexes were dissected from C57Bl/6J mice that were kept in 12-hour light/dark cycles at 3-hour intervals, and their core clock gene (Per1, Per2, and Bmal1) and glucocorticoid receptor mRNA expression were quantified. Iris-CB complexes from period2::luciferase mice were dissected and cultured to measure in vitro rhythmicity. To determine the phase-shifting effect of glucocorticoids on the iris-CB, dexamethasone or vehicle was added to the cultured tissues at defined circadian phases. The diurnal IOP rhythms of adrenalectomized or sham-operated mice under the 12-hour light/dark cycles were also measured. Results: In iris-CB complexes, glucocorticoid receptor mRNA expression remained stable throughout the day, whereas the mRNA of core clock genes showed a robust circadian rhythmicity. Dexamethasone significantly induced phase-delays when administered between circadian time 8 (CT8) to CT12 and phase-advance when given between CT16 to CT20. Adrenalectomy abolished circadian IOP rhythmicity, particularly diminishing nocturnal IOP elevation compared with sham-operated mice. Conclusions: Glucocorticoids are sufficient for phase shifting the circadian clock in iris-CB. Intact adrenal function is required for manifest circadian rhythms of IOP in mice. Taken together, these data are consistent with the hypothesis that glucocorticoids mediate circadian entrainment of IOP to the master circadian oscillator.


Assuntos
Glândulas Suprarrenais/fisiologia , Ritmo Circadiano/fisiologia , Dexametasona/farmacologia , Glucocorticoides/farmacologia , Pressão Intraocular/fisiologia , Adrenalectomia , Animais , Corpo Ciliar/fisiologia , Ritmo Circadiano/efeitos dos fármacos , Feminino , Regulação da Expressão Gênica/fisiologia , Iris/fisiologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fotoperíodo , RNA Mensageiro/genética , Receptores de Glucocorticoides/genética , Tonometria Ocular
10.
PLoS One ; 12(9): e0184790, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28934261

RESUMO

PURPOSE: Intraocular pressure (IOP) is known to have a strong circadian rhythm, yet how light/dark cycles entrain this rhythm is unknown. The purpose of this study was to assess whether, like the retina, the mammalian ciliary body and IOP clocks have an intrinsic ability to entrain to light/dark cycles. METHODS: Iris-ciliary body complexes were obtained from period2:luciferase (PER2::LUC) mice and cultured to measure bioluminescence rhythmicity. Pairs of the iris-ciliary body complex were exposed to antiphasic 9:15 h light/dark cycle in vitro. After 4 days of exposure to light/dark cycles, bioluminescence was recorded to establish their circadian phases. In addition, pairs of the iris-ciliary body complex co-cultured with the retinas or corneas of wild-type mice were also investigated. The IOP circadian changes of free-running Opn4-/-;rd1/rd1 mice whose behavior was antiphasic to wild-type were measured by a rebound tonometry, and compared with wild-type mice. Opn3, Opn4, and Opn5 mRNA expression in the iris-ciliary body were analyzed using RT-PCR. RESULTS: The iris/ciliary body complex expressed Opn3, Opn4, and Opn5 mRNA; however, unlike in retina and cornea, neither the iris-CB complex nor the co-cultured complex was directly entrained by light-dark cycle in vitro. The diurnal IOP change of Opn4-/-;rd1/rd1 mice showed an antiphasic pattern to wild-type mice and their rhythms followed the whole-animal behavioral rhythm. CONCLUSIONS: Despite expressing mRNA for several non-visual opsins, circadian rhythms of the iris-ciliary body complex of mice do not entrain directly to light-dark cycles ex vivo. Unlike retina, the iris/ciliary body clocks of blind mice remain synchronized to the organismal behavioral rhythm rather than local light-dark cycles. These results suggest that IOP rhythm entrainment is mediated by a systemic rather than local signal in mice.


Assuntos
Ritmo Circadiano/fisiologia , Pressão Intraocular/fisiologia , Fotoperíodo , Animais , Corpo Ciliar/fisiologia , Técnicas de Cocultura , Córnea/fisiologia , Feminino , Regulação da Expressão Gênica/fisiologia , Masculino , Proteínas de Membrana/metabolismo , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Opsinas/metabolismo , Proteínas Circadianas Period/genética , Proteínas Circadianas Period/metabolismo , Estimulação Luminosa , RNA Mensageiro/metabolismo , Retina/fisiologia , Opsinas de Bastonetes/genética , Opsinas de Bastonetes/metabolismo
11.
PLoS One ; 12(5): e0177526, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28542230

RESUMO

PURPOSE: To investigate visual field changes after vitrectomy for macular diseases in glaucomatous eyes. METHODS: A retrospective review of 54 eyes from 54 patients with glaucoma, who underwent vitrectomy for epiretinal membrane (ERM; 42 eyes) or macular hole (MH; 12 eyes). Standard automated perimetry (Humphrey visual field 24-2 program) was performed and analyzed preoperatively and twice postoperatively (1st and 2nd sessions; 4.7 ± 2.5, 10.3 ± 3.7 months after surgery, respectively). Postoperative visual field sensitivity at each test point was compared with the preoperative value. Longitudinal changes in mean visual field sensitivity (MVFS) of the 12 test points within 10° eccentricity (center) and the remaining test points (periphery), best-corrected visual acuity (BCVA), intraocular pressure (IOP), and ganglion cell complex (GCC) thickness, and the association of factors with changes in central or peripheral MVFS over time were analyzed using linear mixed-effects models. In addition, 45 eyes from 45 patients without glaucoma who underwent vitrectomy for epiretinal membrane (ERM; 34 eyes) or macular hole (MH; 11 eyes) were similarly examined and statistically analyzed (control group). RESULTS: In glaucomatous eyes, visual field test points changed significantly and reproducibly; two points deteriorated only at the center and twelve points improved only at the periphery. Central MVFS decreased (p = 0.03), whereas peripheral MVFS increased postoperatively (p = 0.010). In the control group, no visual field test points showed deterioration, and central MVFS did not change significantly after vitrectomy. BCVA improved, GCC thickness decreased, and IOP did not change postoperatively in both groups. The linear mixed-effects models identified older age, systemic hypertension, longer axial length, and preoperative medication scores of ≥2 as risk factors for central MVFS deterioration in glaucomatous eyes. CONCLUSIONS: Visual field sensitivity within 10° eccentricity may deteriorate after vitrectomy for ERM or MH in glaucomatous eyes.


Assuntos
Membrana Epirretiniana/complicações , Glaucoma/complicações , Glaucoma/cirurgia , Perfurações Retinianas/complicações , Campos Visuais , Vitrectomia/efeitos adversos , Idoso , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Período Pós-Operatório , Estudos Retrospectivos
12.
Curr Eye Res ; 42(7): 1013-1017, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28121174

RESUMO

PURPOSE: To investigate whether the elimination of ß1- and ß2-adrenergic receptors alters the diurnal intraocular pressure (IOP) rhythm in mice. MATERIALS AND METHODS: ß1-/ß2-adrenergic receptor double-knockout and C57BL/6J mice were anesthetized intraperitoneally, with their IOPs measured via microneedle method. After entrainment to a 12-h light-dark (LD) cycle (light phase 6:00-18:00), IOPs were measured every 3 h from 9:00 to 24:00 (group 1, ß1-/ß2-adrenergic receptor double-knockout mice, n = 11; C57BL/6J, n = 15). The IOP measurements at 15:00 and 24:00 under a 12-h LD cycle and in the constant darkness (1 day and 8 days after exposure to darkness, respectively) were performed in another group of ß1-/ß2-adrenergic receptor double-knockout mice (group 2, n = 12). IOP variance throughout the day and mean IOP differences among time points were evaluated using a linear mixed model. RESULTS: ß1-/ß2-adrenergic receptor double-knockout and C57BL/6J mice showed biphasic IOP curves, low during the light phase and high during the dark phase; the fluctuation was significant (P < 0.001). The peak IOP (18.7 ± 1.4 mmHg) occurred at 24:00 and the trough IOP (13.5 ± 1.5 mmHg) occurred at 15:00 in ß1-/ß2-adrenergic receptor double-knockout mice group. IOP curves of ß1-/ß2-adrenergic receptor double-knockout and C57BL/6J were nearly parallel, and the IOPs of ß1-/ß2-adrenergic receptor double-knockout mice were significantly higher than those of C57BL/6J mice (P < 0.001). Under constant dark (DD) conditions, IOP at 24:00 (18.1 ± 1.5 mmHg) was significantly higher than that at 15:00 (13.3 ± 1.2 mmHg) (P < 0.001). The transition from the LD cycle to DD environment produced no significant change in IOP (P = 0.728). CONCLUSIONS: Elimination of both ß1- and ß2-adrenergic receptors did not disturb the biphasic diurnal IOP rhythm in mice.


Assuntos
Ritmo Circadiano/fisiologia , Pressão Intraocular/fisiologia , Receptores Adrenérgicos beta/metabolismo , Animais , Modelos Animais de Doenças , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Simpatectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...