1.
J Zhejiang Univ Sci ; 5(12): 1565-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15547965

RESUMO

An experimental system was set up to measure the temperature, pressure, heat transfer rate and mass flow rate in a semi-open two-phase thermosyphon. The behaviors of a semi-open two-phase thermosyphon during startup, shutdown and lack of water were studied to get complete understanding of its thermal characteristics. The variation of wall temperature, heat-exchange condition and pressure fluctuations of semi-open two-phase thermosyphons showed that the startup of SOTPT needs about 60-70 min; the startup speed of SOTPT is determined by the startup speed of the condensation section; the average pressure in the heat pipe is equal to the environmental pressure usually; the shutdown of SOTPT needs about 30-50 min; a semi-open two-phase thermosyphon has good response to lack of water accident.


Assuntos
Transferência de Energia , Calefação/instrumentação , Calefação/métodos , Temperatura Alta , Água/química , Cinética , Teste de Materiais , Transição de Fase , Pressão , Temperatura , Condutividade Térmica