Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 35(8): 980-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22816370

RESUMO

BACKGROUND: The different settings of the automatic algorithm in the Carto system (Carto XP, Biosense Webster, Diamond Bar, CA, USA) used for detecting complex fractionated electrograms (CFEs) during atrial fibrillation (AF) may influence the identification of the fragmented electrograms. OBJECTIVES: We aimed to evaluate the impact of the different parameters on the detection of CFEs and the efficacy of the substrate modification after pulmonary vein isolation (PVI). METHODS: A total of 1,159 electrograms were analyzed from 11 consecutive patients (age = 56 ± 12 years). The effect of the different algorithm factors, such as the high-voltage thresholds (0.12, 0.25, 0.5, 20 mV), detection algorithms (average complex interval [ACI] vs interval confidence level), and recording duration (2.5 seconds vs 5 seconds), on the disparities of the CFEs was investigated. RESULTS: The proportion of the different grades of CFEs depended on the detection algorithm and recording duration. The high-voltage threshold would not affect the consistency of the CFEs irrespective of the different settings of the detection algorithm or recording duration. High-grade CFEs were most consistent with an ACI algorithm and recording duration of 5 seconds (Cronbach's alpha = 0.952). Ablation consisting of a PVI and high-grade CFE sites converted AF directly to sinus rhythm in eight of 11 patients or into atrial tachycardia in one of 11. CONCLUSIONS: The distribution and consistency of the CFE detection depended on the detection algorithm and recording duration, but not on the high-voltage threshold. Under the ACI algorithm and a recording duration of 5 seconds, high-grade CFE sites remained highest consistency.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 22(4): 385-93, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20946229

RESUMO

BACKGROUND: Multiple remodeling patterns have been observed after catheter ablation of atrial fibrillation (AF). OBJECTIVE: We aimed to clarify the electrical/structural properties associated with recurrences after ablation of chronic AF. METHODS: After a stepwise ablation procedure in 120 consecutive patients with persistent/long-lasting persistent AF, 36 had a recurrence of AF (Group 1/Group 2: recurrence with paroxysmal/persistent AF, n = 16/20). RESULTS: During the first procedure, the left atrial (LA) bipolar voltage did not differ between the 2 groups, and the LA volume was smaller in Group 1 than in Group 2 and it was the only factor predicting the recurrent types (P = 0.009, OR = 1.04). In the second procedure, the bipolar voltage of the global left atrium increased (1.33 ± 0.11 mV vs 1.76 ± 0.16 mV, P = 0.001) in Group 1 and decreased (1.31 ± 0.14 mV vs 0.90 ± 0.12 mV, P = 0.01) in Group 2, when compared with that of the first procedure. The LA low-voltage area (<0.5 mV) decreased in Group 1, and increased in Group 2. The LA volume (90 ± 8 cm(3) vs 72 ± 8 cm(3), P = 0.002) decreased in the second procedure in Group 1. It remained the same in Group 2. The right atrial substrates did not change between the procedures. After a follow-up of 27 ± 3 months, all patients in Group 1 and 14 patients in Group 2 remained in sinus rhythm (P = 0.02). CONCLUSION: A better outcome with reverse electrical and structural remodeling occurred after the ablation of chronic AF when the recurrence was paroxysmal AF. Progressive electrical remodeling without any structural remodeling developed in those with a recurrence involving persistent AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo/fisiologia , Ablação por Cateter , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Doença Crônica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Cardiovasc Electrophysiol ; 21(1): 21-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19656247

RESUMO

CFAEs and the Voltage. Introduction: Catheter ablation of atrial fibrillation (AF) can be guided by the identification of complex fractionated atrial electrograms (CFAEs). We aimed to study the prediction of the CFAEs defined by an automatic algorithm in different atrial substrates (high voltage areas vs low voltage areas). Methods and Results: This study included 13 patients (age = 56 +/- 12 years, paroxysmal AF = 8 and persistent AF = 5), who underwent mapping and catheter ablation of AF with a NavX system. High-density voltage mapping of the left atrium (LA) was performed during sinus rhythm (SR) (248 +/- 75 sites per patient) followed by that during AF (88 +/- 24 sites per patient). The CFAE maps were based on the automatic-detection algorithm. "Operator-determined CFAEs" were defined according to Nademannee's criteria. A low-voltage zone (LVZ) was defined as a bipolar voltage of less than 0.5 mV during SR. Among a total of 1150 mapping sites, 459 (40%) were categorized as "operator-determined CFAE sites," whereas 691 (60%) were categorized as "operator-determined non-CFAE sites." The sensitivity and negative predictive value increased as the fractionated interval (FI) value of the automatic algorithm increased, but the specificity and positive predictive value decreased. The automatic CFAE algorithm exhibited the highest combined sensitivity and specificity with an FI of <60 ms for the sites inside the LVZ and FI < 70 ms for the sites outside the LVZ, when compared with a single threshold for both the high- and low-voltage groups combined (i.e., no regard for voltage) (ROC: 0.89 vs 0.86). Conclusions: The clinical relevance of the CFAE map would be improved if the calculated index values were accordingly scaled by the electrogram peak-to-peak amplitude.


Assuntos
Algoritmos , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Cardiovasc Electrophysiol ; 20(11): 1211-6, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19602021

RESUMO

BACKGROUND: The left atrial (LA) size is an important predictor of atrial fibrillation (AF) procedural termination and the long-term outcome. We sought to evaluate the long-term outcome in regard to the LA size and procedural termination. METHODS: Eighty-seven consecutive chronic AF patients (72 males, 53 +/- 10 years) underwent 3D mapping (NavX) and ablation. A stepwise approach including circumferential pulmonary vein (PV) isolation, linear ablation, and continuous complex-fractionated electrogram (CFE) ablation (targeting fractionation intervals of < 50 ms). Electrical cardioversion was applied to those without any procedural termination. The freedom from AF was defined as the maintenance of sinus rhythm without the use of any class I or III antiarrhythmic drugs after the blanking period. RESULTS: Among the 87 patients, all received a circumferential PV isolation, 93% a linear ablation, and 59% a continuous CFE ablation. Those with AF procedural termination (n = 30) had a better long-term outcome when compared with those without termination during a follow-up of 21 +/- 12 months. Moreover, a Kaplan-Meier analysis showed that in those with an LA diameter of less than 45 mm (n = 49), the freedom from AF rate was higher when procedural termination was achieved (P = 0.004). On the contrary, the outcome was comparable in those with an LA diameter of >or= 45 mm (n = 38), whether AF procedural termination occurred or not (P = 0.658). CONCLUSIONS: AF procedural termination was related to the long-term success during chronic AF ablation, especially in those with an LA diameter of less than 45 mm. The favorable effect of termination decreased when the LA diameter was >or= 45 mm.


Assuntos
Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Átrios do Coração/patologia , Doença Crônica , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Prognóstico , Resultado do Tratamento
5.
Heart Rhythm ; 6(3): 311-8, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19251203

RESUMO

BACKGROUND: Termination of atrial fibrillation (AF) can be achieved by catheter ablation. It has been used as one of the procedural endpoints for AF ablation. OBJECTIVE: The purpose of this study was to investigate the factors that predict AF termination and the association with long-term outcomes. METHODS: Eighty-five consecutive AF patients (33 paroxysmal, 52 nonparoxysmal) underwent three-dimensional mapping and catheter ablation. A stepwise ablation approach included circumferential pulmonary vein (PV) isolation and left atrial (LA) linear ablation, followed by LA and right atrial (RA) electrogram-based (complex fractionated atrial electrogram) ablation. Clinical and electrophysiologic characteristics were assessed to evaluate the predictors of acute AF termination. RESULTS: In univariate analysis, a diagnosis of paroxysmal AF, shorter AF history, absence of history of heart failure, smaller LA diameter, longer postablation coronary sinus cycle length, lower LA and RA mean dominant frequencies, lower RA max dominant frequency, and higher LA voltage were related to acute termination of AF during ablation. Multivariate analysis showed that smaller LA diameter and lower preablation mean RA dominant frequency were independent predictors of AF termination. Multivariate analysis also showed that larger LA diameter and the presence of RA non-PV ectopy during the index procedure could predict late recurrence during long-term (13 +/- 8 months) follow-up. CONCLUSION: LA size and RA non-PV drivers are important for acute termination of AF and for long-term success. Careful selection of patients, extensive RA mapping, and LA ablation may enhance long-term ablation efficacy.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Cardioversão Elétrica , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...