Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Biomed Pharmacother ; 159: 114099, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36641923

RESUMO

Intervertebral disc degeneration (IVDD), a common cartilage-degenerative disease, is considered the main cause of low back pain (LBP). Owing to the complex aetiology and pathophysiology of IVDD, its molecular mechanisms and definitive treatment of IVDD remain unclear. As an evolutionarily and functionally conserved signalling pathway, Hippo-YAP/TAZ signalling plays a crucial role in IVDD progression. In this review, we discuss the regulation of Hippo-YAP/TAZ signalling and summarise the recent research progress on its role in cartilage homeostasis and IVDD. We also discuss the current application and future prospects of IVDD treatments based on Hippo-YAP/TAZ signalling.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Humanos , Via de Sinalização Hippo , Transdução de Sinais , Proteínas com Motivo de Ligação a PDZ com Coativador Transcricional
2.
Chinese Journal of Surgery ; (12): 203-207, 2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-935600

RESUMO

The modern surgical treatment of cervical degenerative disc disease can be traced back to the advent of anterior cervical decompression and fusion.With the emergence of fusion-related complications,different scholars have promoted the gradual transformation of cervical degenerative disc diseases from "fusion fixation" to "non-fusion reconstruction" through in-depth fusion with materials science,engineering mechanics and other disciplines.The innovation of this treatment concept is consistent with the original intention of "structural remodeling,functional reconstruction,maximum repair and reconstruction of the morphology and function of skeletal muscle system" in orthopedic bionic treatment,which is essentially in line with the "bionic alternative therapy" in orthopedic bionic therapy.This paper focuses on the surgical treatment of cervical degenerative disc diseases,reviews the development history of artificial cervical disc replacement,analyzes the evolution from orthopedic biomimetic therapy,and explores a new direction for the design of artificial cervical disc prostheses and the treatment of cervical degenerative disc diseases in the future.


Assuntos
Humanos , Biônica , Vértebras Cervicais/cirurgia , Discotomia , Seguimentos , Disco Intervertebral/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Fusão Vertebral , Substituição Total de Disco , Resultado do Tratamento
3.
Chinese Medical Journal ; (24): 2594-2600, 2019.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-771163

RESUMO

BACKGROUND@#Reports on the efficacy of modifications to the thread design of pedicle screws are scarce. The aim of the study was to investigate initial and early fixation of pedicle screws with a plasma-sprayed titanium coating and dual pitch in the pedicle region (dual pitch titanium-coated pedicle screw [DPTCPS]) in a polyetheretherketone (PEEK) rod semi-rigid fixation system.@*METHODS@#Fifty-four sheep spine specimens and 64 sheep were used to investigate initial ("0-week" controls) and early (post-operative 6 months) fixation, respectively. Sheep were divided into dual pitch pedicle screw (DPPS), standard pitch pedicle screw (SPPS), DPTCPS, and standard pitch titanium-coated pedicle screw (SPTCPS) groups. Specimens/sheep were instrumented with four screws and two rods. Biomechanical evaluations were performed, and histology at the implant-bone interface was investigated.@*RESULTS@#At 0-week, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (557.0 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.61, P < 0.05; 622.6 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.43, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (343.4 ± 16.5 vs. 237.5 ± 12.9 N, t = 3.52, P < 0.05; 343.4 ± 16.5 vs. 289.9 ± 12.8 N, t = 3.12, P < 0.05; 124.7 ± 13.5 vs. 41.9 ± 4.3 cycles, t = 2.18, P < 0.05; 124.7 ± 13.5 vs.79.5 ± 11.8 cycles, t = 2.76, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (1.8 ± 0.13 vs. 3.76 ± 0.19 mm, t = 2.29, P < 0.05; 1.8 ± 0.13 vs. 2.46 ± 10.20 mm, t = 2.69, P < 0.05). At post-operative 6 months, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (908.4 ± 33.6 vs. 646.5 ± 59.4 N, t = 3.34, P < 0.05; 925.9 ± 53.9 vs. 646.5 ± 59.4 N, t = 3.37, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (496.9 ± 17.9 vs. 370.3 ± 16.4 N, t = 2.86, P < 0.05; 496.9 ± 17.9 vs. 414.1 ± 12.8 N, t = 2.74, P < 0.05; 249.1 ± 11.0 vs.149.9 ± 11.1 cycles, t = 2.54, P < 0.05; 249.1 ± 11.0 vs.199.8 ± 7.2 cycles, t = 2.61, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (0.96 ± 0.11 vs. 2.39 ± 0.14 mm, t = 2.57, P < 0.05; 0.96 ± 0.11 vs. 1.82 ± 0.12 mm, t = 2.73, P < 0.05). Resistance to toggle testing (370.3 ± 16.4 vs. 414.1 ± 12.8 N, t = 3.29, P < 0.05; 149.9 ± 11.1 vs.199.8 ± 7.2 cycles, t = 2.97, P < 0.05) was significantly lower and maximum displacement in cyclic loading (2.39 ± 0.14 vs.1.82 ± 0.12 mm; t = 3.06, P < 0.05) was significantly higher for the SPTCPS than the DPTCPS. Bone-to-implant contact was significantly increased for the DPTCPS compared to the SPPS (58.3% ± 7.0% vs. 36.5% ± 4.4%, t = 2.74, P < 0.05); there was no inflammatory reaction or degradation of coated particles.@*CONCLUSION@#DPTCPSs might have stronger initial and early fixation in a PEEK rod semi-rigid fixation system.

4.
Chinese Medical Journal ; (24): 2594-2600, 2019.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-803153

RESUMO

Background@#Reports on the efficacy of modifications to the thread design of pedicle screws are scarce. The aim of the study was to investigate initial and early fixation of pedicle screws with a plasma-sprayed titanium coating and dual pitch in the pedicle region (dual pitch titanium-coated pedicle screw [DPTCPS]) in a polyetheretherketone (PEEK) rod semi-rigid fixation system.@*Methods@#Fifty-four sheep spine specimens and 64 sheep were used to investigate initial ( "0-week" controls) and early (postoperative 6 months) fixation, respectively. Sheep were divided into dual pitch pedicle screw (DPPS), standard pitch pedicle screw (SPPS), DPTCPS, and standard pitch titanium-coated pedicle screw (SPTCPS) groups. Specimens/sheep were instrumented with four screws and two rods. Biomechanical evaluations were performed, and histology at the implant-bone interface was investigated.@*Results@#At 0-week, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (557.0 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.61, P < 0.05; 622.6 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.43, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (343.4 ± 16.5 vs. 237.5 ± 12.9 N, t = 3.52, P < 0.05; 343.4 ± 16.5 vs. 289.9 ± 12.8 N, t = 3.12, P < 0.05; 124.7 ± 13.5 vs. 41.9 ± 4.3 cycles, t = 2.18, P < 0.05; 124.7 ± 13.5 vs.79.5 ± 11.8 cycles, t = 2.76, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (1.8 ± 0.13 vs. 3.76 ± 0.19 mm, t = 2.29, P < 0.05; 1.8 ± 0.13 vs. 2.46 ± 10.20 mm, t = 2.69, P < 0.05). At post-operative 6 months, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (908.4 ± 33.6 vs. 646.5 ± 59.4 N, t = 3.34, P < 0.05; 925.9 ± 53.9 vs. 646.5 ± 59.4 N, t = 3.37, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (496.9 ± 17.9 vs. 370.3 ± 16.4 N, t = 2.86, P < 0.05; 496.9 ± 17.9 vs. 414.1 ± 12.8 N, t = 2.74, P < 0.05; 249.1 ± 11.0 vs.149.9 ± 11.1 cycles, t = 2.54, P < 0.05; 249.1 ± 11.0 vs.199.8 ± 7.2 cycles, t = 2.61, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (0.96 ± 0.11 vs. 2.39 ± 0.14 mm, t = 2.57, P < 0.05; 0.96 ± 0.11 vs. 1.82 ± 0.12 mm, t = 2.73, P < 0.05). Resistance to toggle testing (370.3 ± 16.4 vs. 414.1 ± 12.8 N, t = 3.29, P < 0.05; 149.9 ± 11.1 vs.199.8 ± 7.2 cycles, t = 2.97, P < 0.05) was significantly lower and maximum displacement in cyclic loading (2.39 ± 0.14 vs.1.82 ± 0.12 mm; t = 3.06, P < 0.05) was significantly higher for the SPTCPS than the DPTCPS. Bone-to-implant contact was significantly increased for the DPTCPS compared to the SPPS (58.3% ± 7.0% vs. 36.5% ± 4.4%, t = 2.74, P < 0.05); there was no inflammatory reaction or degradation of coated particles.@*Conclusion@#DPTCPSs might have stronger initial and early fixation in a PEEK rod semi-rigid fixation system.

5.
Chinese Journal of Surgery ; (12): 1675-1677, 2006.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-334432

RESUMO

<p><b>OBJECTIVE</b>To investigate the diagnostic value of lumbar discography in discogenic low back pain and the effects of intervertebral fusion surgery.</p><p><b>METHODS</b>Forty-five cases with 101 discs underwent discography, 360 degree fusion manipulation were performed on 18 discography abnormal cases, 27 cases were treated conservatively. Discography, MRI and provocative pain were observed and all the cases were followed up.</p><p><b>RESULTS</b>Twenty-one cases showed positive provocative pain (21/45, 47%), and 21 discs of 101 were concordant discography (21/101, 21%). All cases were followed up for an average 16 months (15 to 23 months), the satisfactory rate was 83% (15/18) in the surgery group and 41% (11/27) in the conservative group.</p><p><b>CONCLUSIONS</b>It is concluded that the discography is moderately sensitive in the diagnosis of discogenic low back pain. Furthermore, the short term follow-up reveals that operative group has better pain relief than conservative group.</p>


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artrografia , Métodos , Discotomia , Seguimentos , Disco Intervertebral , Diagnóstico por Imagem , Dor Lombar , Diagnóstico , Cirurgia Geral , Vértebras Lombares , Diagnóstico por Imagem , Sensibilidade e Especificidade , Doenças da Coluna Vertebral , Fusão Vertebral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...