Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 15018, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951542

RESUMO

Many ferroelectric nematic liquid crystals, like one of the archetype materials, DIO, do not have a direct paraelectric N to ferroelectric NF phase transition, but exhibit yet another phase between N and NF. This phase has recently been proposed to be antiferroelectric, with a layered structure of alternating polarization normal to the average director and is sometimes referred to as Smectic ZA (SmZA). We have examined the SmZA phase in circularly rubbed (CR) cells, known to discriminate between the polar NF and the non-polar N phase from the configuration of disclination lines formed. We find that the ground state of SmZA has the same disclination configuration as the non-polar N phase, demonstrating that the SmZA phase is also non-polar, i.e., it has no net ferroelectric polarization. At the same time, the SmZA texture generally has a grainy appearance, which we suggest is partly a result of the frustration related to layered order combined with the imposed twist in CR cells. We discuss possible orientations of the smectic layers, depending on the alignment conditions. While a horizontal SmZA layer structure is always compatible with surface-induced twist, a vertical layer structure would tend to break up in a twisted bookshelf structure to match non-parallel alignment directions at the two surfaces.

2.
Sensors (Basel) ; 14(11): 20519-32, 2014 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-25360580

RESUMO

This report describes the design and development of an integrated electrochemical cell culture monitoring system, based on enzyme-biosensors and chemical sensors, for monitoring indicators of mammalian cell metabolic status. MEMS technology was used to fabricate a microwell-format silicon platform including a thermometer, onto which chemical sensors (pH, O2) and screen-printed biosensors (glucose, lactate), were grafted/deposited. Microwells were formed over the fabricated sensors to give 5-well sensor strips which were interfaced with a multipotentiostat via a bespoke connector box interface. The operation of each sensor/biosensor type was examined individually, and examples of operating devices in five microwells in parallel, in either potentiometric (pH sensing) or amperometric (glucose biosensing) mode are shown. The performance characteristics of the sensors/biosensors indicate that the system could readily be applied to cell culture/toxicity studies.


Assuntos
Técnicas Biossensoriais/instrumentação , Glucose/análise , Neoplasias Experimentais/química , Neoplasias Experimentais/metabolismo , Oximetria/instrumentação , Termografia/instrumentação , Análise Serial de Tecidos/instrumentação , Linhagem Celular Tumoral , Desenho Assistido por Computador , Condutometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/metabolismo , Sistemas Microeletromecânicos/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Integração de Sistemas , Temperatura
3.
ACS Nano ; 4(12): 7401-6, 2010 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-21082817

RESUMO

The highly doped electrodes of a vertical silicon nanogap device have been bridged by a 5.85 nm long molecular wire, which was synthesized in situ by grafting 4-ethynylbenzaldehyde via C-Si links to the top and bottom electrodes and thereafter by coupling an amino-terminated fluorene unit to the aldehyde groups of the activated electrode surfaces. The number of bridging molecules is constrained by relying on surface roughness to match the 5.85 nm length with an electrode gap that is nominally 1 nm wider and may be controlled by varying the reaction time: the device current increases from ≤1 pA at 1 V following the initial grafting step to 10-100 nA at 1 V when reacted for 5-15 min with the amino-terminated linker and 10 µA when reacted for 16-53 h. It is the first time that both ends of a molecular wire have been directly grafted to silicon electrodes, and these molecule-induced changes are reversible. The bridges detach when the device is rinsed with dilute acid solution, which breaks the imine links of the in situ formed wire and causes the current to revert to the subpicoampere leakage value of the 4-ethynylbenzaldehyde-grafted nanogap structure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...