1.
EuroIntervention ; 10(10): 1239-46, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25701511

RESUMO

AIMS: A bipolar multi-electrode 7 Fr-compatible balloon-catheter radiofrequency (RF) renal denervation system (Vessix™ Renal Denervation System; Boston Scientific, Marlborough, MA, USA) was evaluated for safety in domestic swine. METHODS AND RESULTS: Renal arteries of 27 swine received overlapping treatments proximally/single treatments distally to mimic balloon overlap clinically. Each histopathology cohort (30, 90, 180 days) had four RF-treated and three sham-treated (no RF energy delivered) animals, with the response of artery/surrounding nerves to bilateral treatment examined (42 arteries). Scanning electron microscopy of the renal artery flow surface for endothelialisation was performed in six additional pigs (three at each of 30 and 90 days: 12 arteries) following unilateral whole artery treatment with proximal overlap: RF one side, sham the other side. Power was ~1 watt, treatment duration 30 seconds, target temperature 68°C. Renal histology and assessment for off-target injury was performed in all 27 swine. Renal artery thermal injury was transmural and segmental involving <10% to >90% of the circumference (typically 30-60%) with segmental neointimal hyperplasia exceeding shams but haemodynamically trivial (maximum stenosis 17.7%). Healing of necrotic arterial media was by replacement fibrosis. Overlying nerves also became fibrotic. Endothelialisation was focally incomplete at 30 days but confluent at 90 days. No off-target injury occurred outside the renal arteries. CONCLUSIONS: Safety was demonstrated.


Assuntos
Ablação por Cateter/instrumentação , Hipertensão/cirurgia , Artéria Renal/cirurgia , Simpatectomia/instrumentação , Animais , Microscopia Eletrônica de Varredura , Modelos Anatômicos , Neointima/patologia , Artéria Renal/inervação , Artéria Renal/patologia , Sus scrofa
2.
J Pharmacol Exp Ther ; 336(1): 127-33, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20959363

RESUMO

Previous studies from our laboratory demonstrated that melatonin inhibits nitric oxide (NO)-induced relaxation in porcine coronary arteries. The present study was designed to further characterize the mechanisms underlying this inhibitory effect of melatonin. Western immunoblot studies identified the presence of melatonin type 2 (MT(2)) receptors, but not MT(1) or MT(3) receptors, in porcine coronary arteries. Immunohistochemical analysis revealed that MT(2) receptors colocalized with α-actin in the smooth muscle cell layer. In coronary arterial rings suspended in organ chambers for isometric tension recording, melatonin (10(-7) M) inhibited relaxations induced by the exogenous NO donor sodium nitroprusside (SNP; 10(-9) to 10(-5) M) and by the α(2)-adrenoceptor agonist 5-bromo-6-[2-imidazolin-2-yl-amino]-quinoxaline (UK14,304; 10(-9) to 10(-5) M), an endothelium-dependent vasodilator. The inhibitory effect of melatonin on SNP- and UK14,304-induced relaxations was abolished in the presence of the selective MT(2) receptor antagonists 4-phenyl-2-propionamidotetralin (4P-PDOT; 10(-7) M) and luzindole (10(-7) M). In contrast to melatonin, the selective MT(3) receptor agonist 5-methoxycarbonylamino-N-acetyltryptamine (5-MCA-NAT; 10(-7) M) had no effect on the concentration-response curves to either SNP or UK14,304. Melatonin (10(-7) M) had no effect on coronary artery relaxation induced by 8-bromoguanosine 3',5'-cyclic monophosphate, but it significantly attenuated the increase in intracellular cyclic GMP levels in response to SNP (10(-5) M). This effect of melatonin was abolished in the presence of 4P-PDOT (10(-7) M). Taken together, these data support the view that melatonin acts on MT(2) receptors in coronary vascular smooth muscle cells to inhibit NO-induced increases in cyclic GMP and coronary arterial relaxation, thus demonstrating a novel function for MT(2) receptors in the vasculature.


Assuntos
Vasos Coronários/metabolismo , Melatonina/fisiologia , Óxido Nítrico/antagonistas & inibidores , Óxido Nítrico/fisiologia , Receptor MT2 de Melatonina/fisiologia , Vasodilatação/fisiologia , Animais , Vasos Coronários/fisiologia , Melatonina/farmacologia , Músculo Liso Vascular/citologia , Músculo Liso Vascular/metabolismo , Doadores de Óxido Nítrico/farmacologia , Suínos , Vasodilatação/efeitos dos fármacos
3.
EuroIntervention ; 6(5): 630-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21044918

RESUMO

AIMS: In a rabbit denudation model, assess impact of strut thickness on arterial healing by comparing endothelial cell coverage and strut tissue coverage after implantation of bare metal stents of varying thickness; evaluate the effect of an everolimus-eluting stent. METHODS AND RESULTS: Strut tissue coverage and endothelialisation were assessed 14 and 21 days after implantation with scanning electron microscopy quantitation methods and immunostaining against the endothelial cell marker PECAM-1 (CD-31). At 14 days, strut tissue coverage was higher with the stainless steel Liberté stent (88%, 97 µm) versus Express (77%, 132 µm). The platinum chromium Element stent with the thinnest strut (81 µm) had the highest level (95%). By 21 days endothelialisation was complete for all. The everolimus-eluting Element stent had a 1-week delay in luminal endothelialisation but was >89% by 21 days; strut endothelial coverage was >79% in 80% (4/5) of animals, with total strut tissue coverage >95%. CONCLUSIONS: This study demonstrated that strut thickness affects strut tissue coverage post stent implantation and the addition of an everolimus-eluting polymer introduces a short delay in endothelialisation. The results highlight the need to control for aspects of stent design such as strut thickness when comparing across drug-eluting stent platforms.


Assuntos
Angioplastia Coronária com Balão , Vasos Coronários/patologia , Stents Farmacológicos , Células Endoteliais/patologia , Imunossupressores/administração & dosagem , Sirolimo/análogos & derivados , Stents , Animais , Cromo , Vasos Coronários/ultraestrutura , Células Endoteliais/fisiologia , Everolimo , Feminino , Metais , Microscopia Eletrônica de Varredura , Molécula-1 de Adesão Celular Endotelial a Plaquetas/análise , Platina , Desenho de Prótese , Coelhos , Sirolimo/administração & dosagem
4.
J Pharmacol Exp Ther ; 320(3): 1204-8, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17164473

RESUMO

Little is known about the vasomotor effects of sirolimus, and preliminary studies using animal models have provided conflicting results. The present study was designed to determine the effects of sirolimus on vasomotor tone in human blood vessels. Human radial artery segments were cut into rings, denuded of endothelium, and placed into organ chambers for isometric tension recording. Sirolimus (10(-10) to 10(-6) M) caused concentration-dependent relaxation of human arteries contracted with U46619 (9,11-dideoxy-11alpha,9alpha-epoxymethano-prostaglandin F(2alpha); 10(-8) M) [-log (M) EC(50) (pD(2)) = 7.28 +/- 0.1; E(max) = 57 +/- 6%] or phenylephrine (10(-6) M) (pD(2) = 7.16 +/- 0.4; E(max) = 45 +/- 9%). Sirolimus-induced relaxation was unaffected by treatment with indomethacin (10(-5) M) but was nearly abolished in tissues contracted by depolarization with elevated K(+) (60 mM). In U46619-contracted rings, the response to sirolimus was markedly inhibited in the presence of the specific ATP-sensitive potassium (K(ATP)) channel blocker, glyburide (10(-6) M), but was unaffected by treatment with blockers of large conductance, calcium-activated potassium channel (iberiotoxin, 10(-7) M), small conductance, calcium-activated potassium channel (apamin, 10(-6) M), or voltage-gated potassium channel (4-aminopyridine, 10(-3) M). The K(ATP) channel opener, aprikalim (10(-7) to 10(-5) M), caused concentration-dependent relaxations that were inhibited by glyburide (10(-6) M) and abolished in tissues contracted with elevated K(+) (60 mM), thus confirming that K(ATP) channel opening causes relaxation of these arteries. These data suggest that sirolimus, at concentrations attained in vivo, causes relaxation of human arteries, and this effect is mediated by opening of K(ATP) channels in vascular smooth muscle. Reduced vasomotor tone is a heretofore unrecognized action of sirolimus that could potentially contribute to its efficacy in drug-eluting stents.


Assuntos
Trifosfato de Adenosina/metabolismo , Relaxamento Muscular/efeitos dos fármacos , Músculo Liso Vascular/efeitos dos fármacos , Canais de Potássio/metabolismo , Sirolimo/farmacologia , Vasodilatadores/farmacologia , Relação Dose-Resposta a Droga , Humanos , Técnicas In Vitro , Ativação do Canal Iônico/efeitos dos fármacos , Músculo Liso Vascular/metabolismo , Bloqueadores dos Canais de Potássio/farmacologia , Artéria Radial/efeitos dos fármacos , Artéria Radial/metabolismo , Vasoconstritores/farmacologia