Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 21(2): 197-202, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17418731

RESUMO

OBJECTIVE: The air-leak test is recommended as a method of assessing the appropriate size of an uncuffed endotracheal tube (ETT) in children. The authors' primary objective was to determine whether the air-leak test would predict adverse events and reintubations after the removal of the ETT in children who have undergone cardiac surgery. DESIGN: Prospective, observational, clinical study. SETTING: University tertiary care hospital. PATIENTS: Ninety-four children <10 years of age undergoing elective cardiac surgery requiring cardiopulmonary bypass surgery. INTERVENTIONS: The attending anesthesiologist assessed air-leak pressure after intubation in the operating room (OR). In addition, the air-leak test was performed in 42 patients before extubation in the pediatric intensive care unit (PICU). The incidence of adverse events and the number of failed extubations were recorded after removal of the ETT. MEASUREMENTS AND MAIN RESULTS: Eleven of the 94 patients were excluded from the study. Four (4.3%) of the patients died in the PICU before extubation, and 7 patients were excluded for other reasons. The median age of the 83 children was 0.9 years (range 0.01-9.6 years). The total incidences of postextubation adverse events and failed extubations were 30.1% and 8.4%, respectively. An audible air leak < or =25 cmH(2)O airway pressure during the OR phase or before removal of the ETT during the PICU recovery phase had no significant predictive value for the incidence of adverse events (p = 0.63) or reintubations (p = 1.0). The patients undergoing simple and complete operations compared with more complex and incomplete operations had significantly fewer postextubation adverse events (p = 0.03). Neonates did not have a higher risk for postextubation adverse events (p = 0.64) or reintubations (p = 0.26) than older children. CONCLUSION: The air-leak test did not predict an increased risk for postextubation adverse events and reintubations in children undergoing elective congenital heart surgery.


Assuntos
Pressão do Ar , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Intubação Intratraqueal/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Criança , Pré-Escolar , Análise de Falha de Equipamento , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Incidência , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Pediátrica , Intubação Intratraqueal/instrumentação , Modelos Logísticos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Projetos de Pesquisa , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...