Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Glaucoma ; 7(2): 139-147, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37619815

RESUMO

OBJECTIVE: To assess the feasibility of remotely training glaucoma patients to take a 10-session clustered virtual reality (VR) visual field (VF) test (Vivid Vision Perimetry [VVP-10]) at home, analyze results for test-retest variability, and assess correspondence with conventional perimetry. DESIGN: Cross-sectional study. SUBJECTS: Twenty-one subjects with glaucoma were enrolled and included in the feasibility assessment of remote training. Thirty-six eyes were used for test-retest analysis and determination of concordance with the Humphrey Field Analyzer (HFA). METHODS: Subjects were provided with a mobile VR headset containing the VVP-10 test software and trained remotely via video conferencing. Subjects were instructed to complete 10 sessions over a 14-day period. MAIN OUTCOME MEASURES: Feasibility was determined by the number of subjects who were able to independently complete VVP-10 over the 14-day period after 1 remote training session. The intraclass correlation coefficient (ICC) for average fraction seen across 10 sessions and the standard error (SE) of the mean were primary outcome measures for assessing test-retest variability. Correlation with HFA mean sensitivity (MS) across eyes, was a secondary outcome measure. RESULTS: Twenty subjects (95%) successfully completed the VVP-10 test series after 1 training session. The ICC for VVP-10 was 0.95 (95% confidence interval [CI], 0.92-0.97). The mean SE in units of fraction seen was 0.012. The Spearman correlations between VVP-10 average fraction seen and HFA MS were 0.87 (95% CI, 0.66-0.98) for moderate-to-advanced glaucoma eyes, and decreased to 0.67 (95% CI, 0.28-0.94) when all eyes were included. CONCLUSIONS: Remote training of patients at home is feasible, and subsequent remote clustered VF testing using VVP-10 by patients on their own, without any further interactions with caregivers or study staff, was possible. At-home VVP-10 results demonstrated low test-retest variability. Future studies must be conducted to determine if VVP-10, taken at home as convenient for the patient, may be a viable supplement to provide equivalent or complementary results to that of standard in-clinic assessment of visual function in glaucoma. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Estudos Transversais , Transtornos da Visão , Glaucoma/diagnóstico
2.
Cornea ; 42(1): 60-65, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35184126

RESUMO

PURPOSE: The purpose of this study was to investigate the social determinants of health for keratoconus. METHODS: In this retrospective cohort study of patients with keratoconus, the electronic health record was reviewed for keratometry, treatments received, clinical comorbidities, and social characteristics. Outcomes included severe keratoconus at presentation (steep keratometry ≥52 diopters), disease progression (≥0.75 diopters increase from the first to the most recent clinical visit), and corneal transplantation. Logistic regression was used to evaluate factors associated with severity at presentation and corneal transplantation. Cox proportional hazards modeling was used to evaluate progression. RESULTS: A total of 1038 patients with keratoconus were identified, 725 (70%) of whom had baseline imaging. Compared with commercially insured patients, Medicaid recipients were more likely to have severe keratoconus, independent of social and clinical confounders [odds ratio (OR) 1.94, 95% confidence interval (CI), 1.12-3.35, P = 0.017]. Male sex was independently associated with progression (hazard ratio = 1.38, 95% CI, 1.03-1.84, P = 0.030). Medicare and Medicaid recipients were more likely to require transplantation compared with commercially insured patients (OR 2.71, 95% CI, 1.65-4.46, P < 0.001 and OR 1.74, 95% CI, 1.08-2.80, P = 0.022, respectively). Other social determinants of health, including non-White race/ethnicity, limited English proficiency, and unemployment, were associated with the outcomes only in univariate analysis. Obstructive sleep apnea, atopy, body mass index, and tobacco use were not associated with any outcome. CONCLUSIONS: Socioeconomic factors were more consistent predictors of keratoconus severity and corneal transplantation compared with clinical factors that have received relatively greater attention in the keratoconus literature.


Assuntos
Ceratocone , Idoso , Estados Unidos/epidemiologia , Humanos , Masculino , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Estudos Retrospectivos , Medicare , Córnea , Progressão da Doença , Fatores Socioeconômicos , Topografia da Córnea
3.
Ophthalmology ; 130(3): 324-330, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36280185

RESUMO

PURPOSE: We evaluated the noninferiority of 10.4 µl of eye drops eluted with a commercially available eye drop adapter, the Nanodropper (Nanodropper, Inc), on pupillary dilation and cycloplegia in children compared with the standard of care (SOC), 50 µl of eye drops. DESIGN: Prospective randomized trial. PARTICIPANTS: Pediatric patients scheduled for routine pupillary dilation at the University of California, San Francisco, at the Pediatric Ophthalmology Clinic were enrolled. Each participant provided 1 eye for the intervention group (Nanodropper) and 1 eye for the control group (SOC). METHODS: Participants were randomized to receive small-volume dilating drops in 1 eye (Nanodropper) and SOC dilating drops in the other eye. Dilation was performed using 1 drop each of 1% cyclopentolate, 1% tropicamide, and 2.5% phenylephrine. Refraction and pupillometry were obtained before and 30 minutes after dilation. A noninferiority analysis was performed to assess change from before to after dilation in spherical equivalent and in pupil constriction percentage and maximum pupil diameter after dilation. MAIN OUTCOME MEASURES: Spherical equivalent, maximum pupil diameter, and pupil constriction percentage. RESULTS: One hundred eyes of 50 patients were included, with a mean ± standard deviation age of 9 ± 3 years. After controlling for baseline measurements, the spherical equivalent after dilation was 0.05 diopter (D) more (95% confidence interval [CI], -0.28 to 0.37 D) in the Nanodropper arm, which did not achieve noninferiority. Maximum pupil diameter after dilation was lower in the Nanodropper group (mean, -0.01 mm; 95% CI, -0.20 to -0.03), which did achieve noninferiority. Constriction percentage after dilation was 0.57 percentage points more (95% CI, -1.38 to 2.51 percentage points) in the Nanodropper group, which did not achieve noninferiority. CONCLUSIONS: Administration of eye drops using a small-volume adapter demonstrated similar efficacy to SOC in a pediatric population. Strict noninferiority was met only for pupillary dilation and not for cycloplegia or constriction percentage; however, the small differences in the effect of the Nanodropper versus SOC on all primary outcomes were not clinically significant. We conclude that small-volume eye drops have the potential to decrease unnecessary medical waste and medication toxicity while maintaining therapeutic effect. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Midriáticos , Presbiopia , Humanos , Criança , Estudos Prospectivos , Dilatação , Pupila , Tropicamida , Fenilefrina/farmacologia , Soluções Oftálmicas
4.
Clin Ophthalmol ; 16: 3193-3203, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36199804

RESUMO

Purpose: To determine the change in Humphrey visual field and clinical parameters after minimally invasive glaucoma surgery combined with cataract surgery. Patients and Methods: Patients undergoing minimally invasive glaucoma surgery combined with cataract surgery in a multicenter retrospective case series between 2013 and 2021 with reliable preoperative and 12 to 18 month postoperative visual field measurements were included. Devices included iStent, XEN, and Hydrus. Clinical parameters were compared with a generalized linear model with generalized estimating equations between preoperative and postoperative visits including best corrected visual acuity, intraocular pressure, number of glaucoma medications and visual fields. Visual field metrics included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Collaborative Initial Glaucoma Treatment Study (CIGTS) score of total deviation probability and pattern deviation probability. Results: Forty-four eyes from 39 patients were included. During the follow up period, visual acuity improved from 0.23±0.17 to 0.10±0.14 logMAR (mean ± standard deviation, p<0.001), number of glaucoma medications was reduced from 2.68±1.06 to 1.46±1.32 (p<0.001), and intraocular pressure decreased from 17.08±4.23 mmHg to 14.92±3.13 mmHg (p=0.003). Differences across devices were negligible. The only significant difference was a greater reduction in number of glaucoma medications in the XEN group (p<0.001). There were no significant changes in the global parameters of VFI, MD, PSD, or CIGTS. Conclusion: Overall, minimally invasive glaucoma surgery combined with cataract surgery appears to be effective at stabilizing visual field function, reducing intraocular pressure, reducing number of glaucoma medications, and improving visual acuity over a 12 to 18 month follow-up period across MIGS devices.

5.
Am J Ophthalmol Case Rep ; 28: 101723, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36275188

RESUMO

Purpose: To report a case of congenital ciliary body cysts causing microspherophakia, ectopia lentis, and secondary angle closure glaucoma in an infant. Observations: A 16-month-old male was found to have bilateral ciliary body cysts associated with zonular laxity or absence causing microspherophakia and ectopia lentis as demonstrated on multimodal imaging. Additionally, the patient had secondary angle closure glaucoma which was likely multi-factorial related to both lens abnormalities and anterior displacement of the iris from the cysts themselves. The patient underwent lensectomy and cyst removal which resulted in intraocular pressure stabilization and visual rehabilitation. Conclusions and Importance: Congenital ciliary body cysts are a rare cause of lens abnormalities and secondary angle closure glaucoma in children. Information regarding genetic underpinnings or systemic associations is limited.

6.
Clin Ophthalmol ; 16: 2505-2511, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35974902

RESUMO

Purpose: To assess the impact of parental socioeconomic status and keratoconus literacy on pediatric eye rubbing and keratoconus severity. Methods: In this mixed-methods study, pediatric keratoconus patients (age ≤ 18 years) were retrospectively identified. Sociodemographic and clinical characteristics were extracted from the electronic medical record (EMR). Telephone surveys were subsequently conducted to assess parental keratoconus literacy, receipt of counseling on keratoconus prevention, eye rubbing, and household socioeconomic factors not available in the EMR. Parents reporting poor keratoconus literacy were probed via semi-structured interview to explore barriers to their understanding. Results: Forty-eight patients met inclusion criteria, 22 (46%) of whom were reached by telephone. Most patients were insured by Medicaid (73%) and current eye rubbers (82%). Few parents reported good or excellent keratoconus literacy now (32%) or at the time of diagnosis (18%). Parents with a high-school education, limited English proficiency, lower income level, and Medicaid insurance tended to have lower keratoconus literacy, though this was not statistically significant. Parental keratoconus literacy was not correlated with disease severity. High-school education, limited English proficiency, lower income level, and Medicaid insurance were correlated with steeper keratometry readings, which was statistically significant for high-school education. In-depth interviews revealed parents felt unconfident with eye health in general and perceived a personal responsibility for learning more. Conclusion: This is the first study exploring keratoconus literacy from a socioeconomic perspective, demonstrating lower literacy among socioeconomically marginalized parents and a tendency toward more severe disease in their children.

7.
Clin Ophthalmol ; 16: 1357-1363, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35510272

RESUMO

Purpose: To describe trends in the use of corneal topography and tomography for the management of keratoconus patients at a single academic institution and to identify how these trends may be associated with different procedural interventions. Patients and Methods: In this retrospective cohort study, keratoconus patients treated from 2012 to 2019 were identified. The electronic health record was reviewed for the presence of corneal topography or tomography imaging completed within seven days of the first visit and the highest level of intervention at the first and most recent visit. Patients were grouped as pediatric (<18 years) or adult (≥18 years). Chi-square tests and linear regressions were used to evaluate trends and to determine which factors were predictive for receiving corneal collagen cross-linking (CXL) versus other surgical interventions (intrastromal corneal ring segments, lamellar keratoplasty, or penetrating keratoplasty) by the most recent visit. Results: A total of 873 keratoconus patients met inclusion criteria. The use of corneal topography at the first visit remained relatively consistent from 2012 to 2019, while corneal tomography usage at the first visit increased from 3.9% in 2015, when corneal tomography was introduced, to 52.8% in 2019. Each year was associated with an 11.2% ± 1.9% increase in the use of corneal tomography at the first visit in pediatric patients and 6.7% ± 0.5% in adult patients. Use of corneal tomography at the first visit was a significant predictor for receiving CXL procedures (P < 0.001) and a negative predictor for requiring other surgical interventions (P = 0.032) when controlling for the year of the first visit. Conclusion: Obtaining corneal tomography at the first visit has become the standard of care in keratoconus, especially for pediatric patients. Moreover, the increase in corneal tomography imaging has coincided with an increase in CXL procedures and decrease in other surgical interventions.

8.
J Ophthalmol ; 2022: 6182592, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35607610

RESUMO

Purpose: To evaluate the correlation of optical coherence tomography angiography (OCTA) and spectral-domain optical coherence tomography (SD-OCT) with visual field for global and sector-based indices among glaucoma and glaucoma-suspected eyes. Patients and Methods. This is a retrospective study, and in total, 48 glaucoma eyes and 31 glaucoma suspect eyes were included. The correlation between visual field parameters and radial peripapillary capillary (RPC) vessel density via OCTA was compared to the correlation with retinal nerve fiber layer (RNFL) thickness via SD-OCT. The RPC vessel density and RNFL thickness were divided into eight sectors, which included the temporal upper, temporal lower, superotemporal, inferotemporal, superonasal, inferonasal, nasal upper, and nasal lower sectors. Pearson correlations with 95% confidence intervals were calculated with resampling, and correlations were compared with a Fisher Z transformation. Results: Both RPC vessel density (R = 0.63, 95% CI [0.24, 0.86]) and RNFL thickness (R = 0.49, 95% CI [0.23, 0.69]) were correlated with the mean deviation when comparing global indices of glaucoma patients. In glaucoma suspects, the correlations between the mean deviation and RPC vessel density (R = 0.21, 95% CI [-0.05, 0.49]) and RNFL thickness (R = 0.01, 95% CI [-0.35, 0.39]) were not significant. Glaucoma eyes had the highest correlation between the mean sensitivity and RPC vessel density and RNFL thickness for the superotemporal, superonasal, temporal upper, and inferotemporal sectors. Conclusion: Across a diverse population and heterogeneous glaucoma types, RPC vessel density measurements correlate with global and sector-wise visual field indices similar to RNFL thickness.

9.
Ophthalmol Sci ; 1(2)2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35756578

RESUMO

Purpose: To investigate ON-pathway versus OFF-pathway dysfunction in glaucoma using handheld electroretinography (ERG) with a temporally modulated sinusoidal flicker stimulus. Design: Cross-sectional study. Participants: Fifty-nine participants accounting for 104 eyes, comprised of 19 control eyes, 26 glaucoma suspect eyes, and 59 glaucoma eyes. Methods: Participants underwent portable ERG testing, which included the photopic flash, photopic flicker, photopic negative response stimulus, ON-OFF stimulus, and a custom-written sinusoidal flicker stimulus that was modulated from 50 to 0.3 Hz. Main Outcome and Measures: The ERG response amplitudes were measured by the handheld ERG. For the custom-written sinusoidal flicker stimulus, we derived and compared the log10 first harmonic frequency response amplitudes. Patient discomfort and fatigue after ERG testing were rated on a scale from 1 to 5. Results: Baseline demographics were not significantly different between groups, except for ocular characteristics. Analysis was performed adjusting for participant age, sex, race, and dilation status, and the sinusoidal frequency responses were stratified at 10 Hz because higher frequencies are associated with the OFF-pathway, whereas lower frequencies are associated with the ON-pathway. After stratification, glaucoma eyes showed an adjusted decrease of 32.1% at frequencies of more than 10 Hz (95% confidence interval [CI], -51.8% to -4.1%; P = 0.03). For 10 Hz stimulus frequencies or less, an adjusted 11.5% reduction was found (95% CI, -39.5% to 29.1%; P = 0.50). Glaucoma suspect eyes did show a decreased response, but this was not significant at either frequency range. When comparing handheld ERG with traditional visual field assessments, participants found the handheld ERG to result in much less discomfort and fatigue. Conclusions: Our finding that glaucoma participants showed greater decreases in ERG response at higher frequencies supports the hypothesis that the OFF-pathway may be more vulnerable in human glaucoma. Using a handheld ERG device with a sinusoidal flicker stimulus may provide an objective assessment of visual function in glaucoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...