Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
bioRxiv ; 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-36993629

RESUMO

Neural circuit function is shaped both by the cell types that comprise the circuit and the connections between those cell types 1 . Neural cell types have previously been defined by morphology 2, 3 , electrophysiology 4, 5 , transcriptomic expression 6-8 , connectivity 9-13 , or even a combination of such modalities 14-16 . More recently, the Patch-seq technique has enabled the characterization of morphology (M), electrophysiology (E), and transcriptomic (T) properties from individual cells 17-20 . Using this technique, these properties were integrated to define 28, inhibitory multimodal, MET-types in mouse primary visual cortex 21 . It is unknown how these MET-types connect within the broader cortical circuitry however. Here we show that we can predict the MET-type identity of inhibitory cells within a large-scale electron microscopy (EM) dataset and these MET-types have distinct ultrastructural features and synapse connectivity patterns. We found that EM Martinotti cells, a well defined morphological cell type 22, 23 known to be Somatostatin positive (Sst+) 24, 25 , were successfully predicted to belong to Sst+ MET-types. Each identified MET-type had distinct axon myelination patterns and synapsed onto specific excitatory targets. Our results demonstrate that morphological features can be used to link cell type identities across imaging modalities, which enables further comparison of connectivity in relation to transcriptomic or electrophysiological properties. Furthermore, our results show that MET-types have distinct connectivity patterns, supporting the use of MET-types and connectivity to meaningfully define cell types.

2.
BJS Open ; 5(1)2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33609398

RESUMO

BACKGROUND: Biological and synthetic meshes may improve the outcomes of immediate implant-based breast reconstruction (IBBR) by facilitating single-stage procedures and improving cosmesis. Supporting evidence is, however, limited. The aim of this study was to explore the impact of biological and synthetic mesh on patient-reported outcomes (PROs) of IBBR 18 months after surgery. METHODS: Consecutive women undergoing immediate IBBR between February 2014 and June 2016 were recruited to the study. Demographic, operative, oncological and 3-month complication data were collected, and patients received validated BREAST-Q questionnaires at 18 months. The impact of different IBBR techniques on PROs were explored using mixed-effects regression models adjusted for clinically relevant confounders, and including a random effect to account for clustering by centre. RESULTS: A total of 1470 participants consented to receive the questionnaire and 891 completed it. Of these, 67 women underwent two-stage submuscular reconstructions. Some 764 patients had a submuscular reconstruction with biological mesh (495 women), synthetic mesh (95) or dermal sling (174). Fourteen patients had a prepectoral reconstruction. Compared with two-stage submuscular reconstructions, no significant differences in PROs were seen in biological or synthetic mesh-assisted or dermal sling procedures. However, patients undergoing prepectoral IBBR reported better satisfaction with breasts (adjusted mean difference +6.63, 95 per cent c.i. 1.65 to11.61; P = 0.009). PROs were similar to those in the National Mastectomy and Breast Reconstruction Audit 2008-2009 cohort, which included two-stage submuscular procedures only. CONCLUSION: This study found no difference in PROs of subpectoral IBBR with or without biological or synthetic mesh, but provides early data to suggest improved satisfaction with breasts following prepectoral reconstruction. Robust evaluation is required before this approach can be adopted as standard practice.


Assuntos
Implante Mamário/métodos , Neoplasias da Mama/cirurgia , Mastectomia/métodos , Medidas de Resultados Relatados pelo Paciente , Telas Cirúrgicas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante Mamário/efeitos adversos , Neoplasias da Mama/patologia , Feminino , Humanos , Modelos Lineares , Modelos Logísticos , Mastectomia/efeitos adversos , Pessoa de Meia-Idade , Satisfação do Paciente , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/psicologia , Estudos Prospectivos , Reino Unido , Adulto Jovem
3.
Stat Med ; 34(12): 2062-80, 2015 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-25809313

RESUMO

Missing outcome data are a common threat to the validity of the results from randomised controlled trials (RCTs), which, if not analysed appropriately, can lead to misleading treatment effect estimates. Studies with missing outcome data also threaten the validity of any meta-analysis that includes them. A conceptually simple Bayesian framework is proposed, to account for uncertainty due to missing binary outcome data in meta-analysis. A pattern-mixture model is fitted, which allows the incorporation of prior information on a parameter describing the missingness mechanism. We describe several alternative parameterisations, with the simplest being a prior on the probability of an event in the missing individuals. We describe a series of structural assumptions that can be made concerning the missingness parameters. We use some artificial data scenarios to demonstrate the ability of the model to produce a bias-adjusted estimate of treatment effect that accounts for uncertainty. A meta-analysis of haloperidol versus placebo for schizophrenia is used to illustrate the model. We end with a discussion of elicitation of priors, issues with poor reporting and potential extensions of the framework. Our framework allows one to make the best use of evidence produced from RCTs with missing outcome data in a meta-analysis, accounts for any uncertainty induced by missing data and fits easily into a wider evidence synthesis framework for medical decision making.


Assuntos
Interpretação Estatística de Dados , Metanálise como Assunto , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Literatura de Revisão como Assunto , Incerteza , Antipsicóticos/administração & dosagem , Antipsicóticos/uso terapêutico , Teorema de Bayes , Viés , Relação Dose-Resposta a Droga , Haloperidol/administração & dosagem , Haloperidol/uso terapêutico , Humanos , Modelos Estatísticos , Avaliação de Resultados em Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Esquizofrenia/tratamento farmacológico
4.
Biosens Bioelectron ; 17(6-7): 495-501, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11959470

RESUMO

The potential for biosensors to contribute to on-line toxicity testing for monitoring of water quality is currently constrained both by the relevance of the biosensors available and the technology for biosensor delivery. This paper reports the use of novel slow release biosensor delivery for on-line monitoring instrumentation, with environmentally relevant bacteria for both simple toxicity testing and more complex toxicity fingerprinting of industrial effluents. The on-line toxicity test, using bioluminescence-based biosensors, proved to be as sensitive and reliable as the corresponding batch test, with comparable contaminant EC(50) values from both methods. Toxicity fingerprinting through the investigation of the kinetics (dose-response) and the dynamics (response with time) of the biosensor test response proved to be diagnostic of both effluent type and composition. Furthermore, the slow release of biosensors immobilised in a polyvinyl alcohol (PVA) matrix greatly improved biosensor delivery, did not affect the sensitivity of toxicity testing, and demonstrated great potential for inclusion in on-line monitoring instrumentation.


Assuntos
Técnicas Biossensoriais/instrumentação , Monitoramento Ambiental/métodos , Escherichia coli/metabolismo , Álcool de Polivinil/química , Poluentes Químicos da Água/administração & dosagem , Poluentes Químicos da Água/análise , Técnicas Biossensoriais/métodos , Preparações de Ação Retardada , Relação Dose-Resposta a Droga , Processamento Eletrônico de Dados , Monitoramento Ambiental/instrumentação , Escherichia coli/efeitos dos fármacos , Escherichia coli/genética , Estudos de Viabilidade , Medições Luminescentes , Sensibilidade e Especificidade , Poluentes Químicos da Água/metabolismo
5.
Environ Toxicol Chem ; 20(11): 2456-61, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11699769

RESUMO

A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95% test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83% identification success was achieved, with no false positives at the 95% test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Escherichia coli/fisiologia , Medições Luminescentes , Algoritmos , Bioensaio/métodos , Disponibilidade Biológica , Biomarcadores , Calibragem , Poluentes Ambientais/toxicidade , Escherichia coli/genética , Plasmídeos , Testes de Toxicidade
6.
Occup Med ; 8(1): 143-54, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8456345

RESUMO

Because respirators may have adverse effects on an individual, it is important that the occupational physician understand these effects and appropriate respirator use in the mining industry. Few studies have been performed on the effects of respirator wear among workers who may have some physiologic impairment. This chapter reviews the relevant regulations, types of respirators used in the mining industry, and the various effects of their use, as well as provides reasonable guidelines for determining fitness to wear these devices.


Assuntos
Mineração/legislação & jurisprudência , Dispositivos de Proteção Respiratória/efeitos adversos , Contraindicações , Humanos , Dispositivos de Proteção Respiratória/classificação , Estados Unidos
7.
J Appl Physiol (1985) ; 68(5): 1902-8, 1990 May.
Artigo em Inglês | MEDLINE | ID: mdl-2361893

RESUMO

Seven young (Y, 22-28 yr) and seven middle-aged (MA, 49-60 yr) normotensive men of similar body size, fatness, and maximal oxygen uptake (VO2max) were exposed to a heat challenge in an environmental chamber (48 degrees C, 15% relative humidity). Tests were performed in two hydration states: hydrated (H, 25 ml water/kg body wt 1 h before the test, 2.5 h before exercise) and hypohydrated (Hypo, after 18-20 h of water deprivation). Each test began with a 90-min rest period during which the transiently increased plasma volume and decreased osmolality after drinking in the H condition returned to base line. This period was followed by 30 min of cycle exercise at a mean intensity of 43% VO2max and a 60-min resting recovery period with water ad libitum. Although prior drinking caused no sustained changes in plasma osmolality, Hypo increased plasma osmolality by 7-10 mosmol/kg in both groups. There were no significant age differences in water intake, urine output or osmolality, overall change in body weight, or sweating rate. In the H state, the percent change in plasma volume was less (P less than 0.01) during exercise for the Y group (-5.9 +/- 0.7%) than for the MA group (-9.4 +/- 0.6%). Esophageal temperature (Tes) was higher in the Hypo condition for both groups with no age-related differences. Throughout the 3-h period, mean skin temperature was higher in the Y group and significantly so (P less than 0.05) in the Hypo condition.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Envelhecimento/fisiologia , Desidratação/fisiopatologia , Hemodinâmica/fisiologia , Temperatura Alta/efeitos adversos , Adulto , Regulação da Temperatura Corporal/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Pele/irrigação sanguínea , Estresse Fisiológico/fisiopatologia , Vasodilatação/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...