Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Perinat Neonatal Nurs ; 34(4): 310-318, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27513609

RESUMO

To prospectively assess the impact of a standardized 5-category Obstetrical Triage Acuity Scale (OTAS) and a fast-track for lower-acuity patients on patient flow. Length of stay (LOS) data of women presenting to obstetric triage were abstracted from the electronic medical record prior to (July 1, 2011, to March 30, 2012) and following OTAS implementation (April 1 to December 31, 2012). Following computerized simulation modeling, a fast-track for lower acuity women was implemented (January 1, 2013, to February 28, 2014). Prior to OTAS implementation (8085 visits), the median LOS was 105 (interquartile range [IQR] = 52-178) minutes. Following OTAS implementation (8131 visits), the median LOS decreased to 101 (IQR = 49-175) minutes (P = .04). The LOS did not correlate well with acuity. Simulation modeling predicted that a fast-track for OTAS 4 and 5 patients would reduce the LOS. The LOS for lower-acuity patients in the fast-track decreased to 73 (IQR = 40-140) minutes (P = .005). In addition, the overall LOS (12 576 visits) decreased to 98 (IQR = 47-172) minutes (6.9% reduction; P < .001). Standardized assessment of acuity and a fast-track for lower acuity pregnant women decreased the overall LOS and the LOS of lower-acuity patients.


Assuntos
Tempo de Internação , Gravidade do Paciente , Medição de Risco , Triagem , Adulto , Simulação por Computador , Registros Eletrônicos de Saúde/estatística & dados numéricos , Feminino , Humanos , Gravidez , Melhoria de Qualidade , Medição de Risco/métodos , Medição de Risco/normas , Estatística como Assunto , Tempo para o Tratamento , Triagem/métodos , Triagem/normas
2.
J Obstet Gynaecol Can ; 38(2): 125-33, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27032736

RESUMO

OBJECTIVE: A five-category Obstetrical Triage Acuity Scale (OTAS) was developed with a comprehensive set of obstetrical determinants. The purposes of this study were: (1) to compare the inter-rater reliability (IRR) in tertiary and community hospital settings and measure the intra-rater reliability (ITR) of OTAS; (2) to establish the validity of OTAS; and (3) to present the first revision of OTAS from the National Obstetrical Triage Working Group. METHODS: To assess IRR, obstetrical triage nurses were randomly selected from London Health Sciences Centre (LHSC) (n = 8), Stratford General Hospital (n = 11), and Chatham General Hospital (n= 7) to assign acuity levels to clinical scenarios based on actual patient visits. At LHSC, a group of nurses were retested at nine months to measure ITR. To assess validity, OTAS acuity level was correlated with measures of resource utilization. RESULTS: OTAS has significant and comparable IRR in a tertiary care hospital and in two community hospitals. Repeat assessment in a cohort of nurses demonstrated significant ITR. Acuity level correlated significantly with performance of routine and second order laboratory investigations, point of care ultrasound, nursing work load, and health care provider attendance. A National Obstetrical Triage Working Group was formed and guided the first revision. Four acuity modifiers were added based on hemodynamics, respiratory distress, cervical dilatation, and fetal well-being. CONCLUSION: OTAS is the first obstetrical triage scale with established reliability and validity. OTAS enables standardized assessments of acuity within and across institutions. Further, it facilitates assessment of patient care and flow based on acuity.


Assuntos
Unidade Hospitalar de Ginecologia e Obstetrícia/estatística & dados numéricos , Obstetrícia/métodos , Gravidade do Paciente , Complicações na Gravidez/classificação , Complicações na Gravidez/diagnóstico , Triagem/métodos , Feminino , Humanos , Gravidez , Reprodutibilidade dos Testes
3.
Am J Obstet Gynecol ; 209(4): 287-93, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23535239

RESUMO

A 5-category Obstetric Triage Acuity Scale (OTAS) was developed with a comprehensive set of obstetrical determinants. The objectives of this study were as follows: (1) to test the interrater reliability of OTAS and (2) to determine the distribution of patient acuity and flow by OTAS level. To test the interrater reliability, 110 triage charts were used to generate vignettes and the consistency of the OTAS level assigned by 8 triage nurses was measured. OTAS performed with substantial (Kappa, 0.61 - 0.77, OTAS 1-4) and near perfect correlation (0.87, OTAS 5). To assess patient flow, the times to primary and secondary health care provider assessments and lengths of stay stratified by acuity were abstracted from the patient management system. Two-thirds of triage visits were low acuity (OTAS 4, 5). There was a decrease in length of stay (median [interquartile range], minutes) as acuity decreased from OTAS 1 (120.0 [156.0] minutes) to OTAS 3 (75.0 [120.8]). The major contributor to length of stay was time to secondary health care provider assessment and this did not change with acuity. The percentage of patients admitted to the antenatal or birthing unit decreased from 80% (OTAS 1) to 12% (OTAS 5). OTAS provides a reliable assessment of acuity and its implementation has allowed for triaging of obstetric patients based on acuity, and a more in-depth assessment of the patient flow. By standardizing assessment, OTAS allows for opportunities to improve performance and make comparisons of patient care and flow across organizations.


Assuntos
Trabalho de Parto , Complicações do Trabalho de Parto/diagnóstico , Obstetrícia/métodos , Complicações na Gravidez/diagnóstico , Triagem/métodos , Feminino , Humanos , Tempo de Internação , Gravidez , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo