Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 31(7): 785-91, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25900891

RESUMO

PURPOSE: To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel phantom. METHODS: Automatic exposure control of full field digital mammography system was used for the selection of the X-ray spectrum and the exposure settings for dual energy imaging. Measurements of the air-kerma and of the half value layers were performed and a Monte Carlo simulation of the digital mammography system was used to compute the mean glandular dose, for breast phantoms of various thicknesses, glandularities and for different X-ray spectra (low and high energy). RESULTS: For breast phantoms of 2.0-8.0 cm thick and 0.1-100% glandular fraction, CC view acquisition, from AEC settings, can result in a mean glandular dose of 0.450 ± 0.022 mGy -2.575 ± 0.033 mGy for low energy images and 0.061 ± 0.021 mGy - 0.232 ± 0.033 mGy for high energy images. In MLO view acquisition mean glandular dose values ranged between 0.488 ± 0.007 mGy - 2.080 ± 0.021 mGy for low energy images and 0.065 ± 0.012 mGy - 0.215 ± 0.010 mGy for high energy images. CONCLUSION: The low kV part of contrast enhanced digital mammography is the main contributor to total mean glandular breast dose. The results of this study can be used to provide an estimated mean glandular dose for individual cases.


Assuntos
Meios de Contraste , Mamografia/instrumentação , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Adulto , Feminino , Humanos , Radiometria
2.
Radiat Prot Dosimetry ; 165(1-4): 369-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25836682

RESUMO

Mammography is a standard procedure that facilitates breast cancer detection. Initial results of contrast-enhanced digital mammography (CEDM) are promising. The purpose of this study is to assess the CEDM radiation dose using a Monte Carlo code. EGSnrc MC code was used to simulate the interaction of photons with matter and estimate the glandular dose (Dg). A voxel female human phantom with a 2-8-cm breast thickness range and a breast glandular composition of 50 % was applied. Dg values ranged between 0.96 and 1.45 mGy (low and high energy). Dg values for a breast thickness of 5.0 cm and a glandular fraction of 50 % for craniocaudal and mediolateral oblique view were 1.12 (low energy image contribution is 0.98 mGy) and 1.07 (low energy image contribution is 0.95 mGy), respectively. The low kV part of CEDM is the main contributor to total glandular breast dose.


Assuntos
Absorciometria de Fóton/métodos , Meios de Contraste , Mamografia/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Adulto , Ar , Mama/patologia , Simulação por Computador , Feminino , Humanos , Método de Monte Carlo , Neovascularização Patológica , Doses de Radiação , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...