Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Anat ; 23(5): 530-8, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20544949

RESUMO

The loss of articular cartilage characteristic of osteoarthritis can only be diagnosed by joint space narrowing when conventional radiography is used. This is due to the lack of X-ray contrast of soft tissues. Whereas conventional radiography harnesses the X-ray attenuation properties of tissues, Diffraction Enhanced Imaging (DEI), a novel radiographic technique, allows the visualization of soft tissues simultaneous with calcified tissues by virtue of its ability to not only harness X-ray attenuation but also the X-ray refraction from tissue boundaries. Previously, DEI was dependent upon synchrotron X-rays, but more recently, the development of nonsynchrotron DEI units has been explored. These developments serve to elaborate the full potential of radiography. Here, we tested the potential of an in-laboratory DEI system, called Diffraction-Enhanced X-ray Imaging (DEXI), to render images of articular cartilage displaying varying degrees of degradation, ex vivo. DEXI allowed visualization of even early stages of cartilage degeneration such as surface fibrillation. This may be of eventual clinical significance for the diagnosis of early stages of degeneration, or at the very least, to visualize soft tissue degeneration simultaneous with bone changes.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Difração de Raios X/métodos , Articulação do Tornozelo/patologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Cartilagem Articular/patologia , Diagnóstico Precoce , Humanos , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Tálus/diagnóstico por imagem , Tálus/patologia , Ecrans Intensificadores para Raios X
2.
Rev Sci Instrum ; 80(9): 093702, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19791939

RESUMO

We describe the design and application of a new in-laboratory diffraction-enhanced x-ray imaging (DEXI) instrument that uses a nonsynchrotron, conventional x-ray source to image the internal structure of an object. In the work presented here, a human cadaveric thumb is used as a test-sample to demonstrate the imaging capability of our instrument. A 22 keV monochromatic x-ray beam is prepared using a mismatched, two-crystal monochromator; a silicon analyzer crystal is placed in a parallel crystal geometry with the monochromator allowing both diffraction-enhanced imaging and multiple-imaging radiography to be performed. The DEXI instrument was found to have an experimentally determined spatial resolution of 160+/-7 mum in the horizontal direction and 153+/-7 mum in the vertical direction. As applied to biomedical imaging, the DEXI instrument can detect soft tissues, such as tendons and other connective tissues, that are normally difficult or impossible to image via conventional x-ray techniques.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Radiografia/instrumentação , Difração de Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Phys Chem A ; 110(4): 1408-15, 2006 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-16435801

RESUMO

The reaction of 5-40 eV O(+) and Ne(+) ions with alkanethiolate and semifluorinated alkanethiolate self-assembled monolayers (SAMs) is studied under ultrahigh vacuum (UHV) conditions. Whereas Ne(+) simply sputters fragments from the surface, O(+) can also abstract surface atoms and break C-C bonds in both the hydrocarbon and fluorocarbon SAM chains. Isotopic labeling experiments reveal that O(+) initially abstracts hydrogen atoms from the outermost two carbon atoms on an alkanethiolate SAM chain. However, the position of the isotopic label quickly becomes scrambled along the chain as the SAM is damaged through continuous ion bombardment. Scanning tunneling microscopy (STM) monitors changes in the SAM conformational structure at various stages during 5 eV ion bombardment. STM images indicate that O(+) reacts less efficiently with dodecanethiolate molecules packed internally within a structural domain than it does with molecules adsorbed at domain boundaries or near defect sites. STM images recorded after Ne(+) bombardment suggest that Ne(+) attacks the SAM exclusively near the domain boundaries. Taken collectively, these experiments advance our understanding of the degradation pathways suffered by polymeric satellite materials in the low-earth orbit (LEO) space environment.


Assuntos
Ouro/química , Membranas Artificiais , Neônio/química , Oxigênio/química , Íons Pesados , Íons , Microscopia de Tunelamento , Propriedades de Superfície
4.
J Am Chem Soc ; 126(41): 13232-3, 2004 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-15479071

RESUMO

Site-specific reaction of hyperthermal O+ with a self-assembled monolayer is described. Isotopic labeling experiments reveal the percentage of abstraction products formed from hydrogen atoms bound originally to the top three carbon atoms in the chain.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA