Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 14(17): 1917-1923, 2021 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-34391704

RESUMO

OBJECTIVES: The aim of this study was to evaluate the 1-year safety and efficacy of a dual-layered stent (DLS) for carotid artery stenting (CAS) in a multicenter registry. BACKGROUND: DLS have been proved to be safe and efficient during short-term follow-up. Recent data have raised the concern that the benefit of CAS performed with using a DLS may be hampered by a higher restenosis rate at 1 year. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system at 20 centers. The primary endpoint was the occurrence of death and stroke at 1 year. Secondary endpoints were 1-year rates of transient ischemic attack, acute myocardial infarction, internal carotid artery (ICA) restenosis, in-stent thrombosis, and external carotid artery occlusion. RESULTS: At 1 year, follow-up was available in 726 patients (99.04%). Beyond 30 days postprocedure, 1 minor stroke (0.13%), four transient ischemic attacks (0.55%), 2 fatal acute myocardial infarctions (0.27%), and 6 noncardiac deaths (1.10%) occurred. On duplex ultrasound examination, ICA restenosis was found in 6 patients (0.82%): 2 total occlusions and 4 in-stent restenoses. No predictors of target ICA restenosis and/or occlusion could be detected, and dual-antiplatelet therapy duration (90 days vs 30 days) was not found to be related to major adverse cardiovascular event or restenosis occurrence. CONCLUSIONS: This real-world registry suggests that DLS use in clinical practice is safe and associated with minimal occurrence of adverse neurologic events up to 12-month follow-up.


Assuntos
Estenose das Carótidas , Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Humanos , Estudos Prospectivos , Stents , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 13(18): 2170-2177, 2020 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-32861633

RESUMO

OBJECTIVES: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. BACKGROUND: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. RESULTS: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. CONCLUSIONS: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Estudos Prospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...