Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
2.
J Vis Exp ; (207)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38801263

RESUMO

The detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a robust and quantitative evaluation. This paper describes a protocol to evaluate these impairments using a hybrid near-infrared diffuse optical device. The device contains modules for near-infrared time-resolved and diffuse correlation spectroscopies and pulse-oximetry. These modules allow the non-invasive, continuous, and real-time measurement of the absolute, microvascular blood/tissue oxygen saturation (StO2) and the blood flow index (BFI) along with the peripheral arterial oxygen saturation (SpO2). This device uses an integrated, computer-controlled tourniquet system to execute a standardized protocol with optical data acquisition from the brachioradialis muscle. The standardized vascular occlusion test (VOT) takes care of the variations in the occlusion duration and pressure reported in the literature, while the automation minimizes inter-operator differences. The protocol we describe focuses on a 3-min occlusion period but the details described in this paper can readily be adapted to other durations and cuff pressures, as well as other muscles. The inclusion of an extended baseline and post-occlusion recovery period measurement allows the quantification of the baseline values for all the parameters and the blood/tissue deoxygenation rate that corresponds to the metabolic rate of oxygen consumption. Once the cuff is released, we characterize the tissue reoxygenation rate, magnitude, and duration of the hyperemic response in BFI and StO2. These latter parameters correspond to the quantification of the reactive hyperemia, which provides information about the endothelial function. Furthermore, the above-mentioned measurements of the absolute concentration of oxygenated and deoxygenated hemoglobin, BFI, the derived metabolic rate of oxygen consumption, StO2, and SpO2 provide a yet-to-be-explored rich data set that can exhibit disease severity, personalized therapeutics, and management interventions.


Assuntos
Cuidados Críticos , Hiperemia , Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Hiperemia/metabolismo , Humanos , Cuidados Críticos/métodos , Oxigênio/metabolismo , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Oximetria/métodos , Oximetria/instrumentação , Músculo Esquelético/metabolismo , Músculo Esquelético/irrigação sanguínea , Microcirculação/fisiologia , Microvasos/metabolismo , Saturação de Oxigênio/fisiologia
3.
Physiol Meas ; 44(12)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38061053

RESUMO

Objective.In this paper, we present a detailedin vivocharacterization of the optical and hemodynamic properties of the human sternocleidomastoid muscle (SCM), obtained through ultrasound-guided near-infrared time-domain and diffuse correlation spectroscopies.Approach.A total of sixty-five subjects (forty-nine females, sixteen males) among healthy volunteers and thyroid nodule patients have been recruited for the study. Their SCM hemodynamic (oxy-, deoxy- and total hemoglobin concentrations, blood flow, blood oxygen saturation and metabolic rate of oxygen extraction) and optical properties (wavelength dependent absorption and reduced scattering coefficients) have been measured by the use of a novel hybrid device combining in a single unit time-domain near-infrared spectroscopy, diffuse correlation spectroscopy and simultaneous ultrasound imaging.Main results.We provide detailed tables of the results related to SCM baseline (i.e. muscle at rest) properties, and reveal significant differences on the measured parameters due to variables such as side of the neck, sex, age, body mass index, depth and thickness of the muscle, allowing future clinical studies to take into account such dependencies.Significance.The non-invasive monitoring of the hemodynamics and metabolism of the sternocleidomastoid muscle during respiration became a topic of increased interest partially due to the increased use of mechanical ventilation during the COVID-19 pandemic. Near-infrared diffuse optical spectroscopies were proposed as potential practical monitors of increased recruitment of SCM during respiratory distress. They can provide clinically relevant information on the degree of the patient's respiratory effort that is needed to maintain an optimal minute ventilation, with potential clinical application ranging from evaluating chronic pulmonary diseases to more acute settings, such as acute respiratory failure, or to determine the readiness to wean from invasive mechanical ventilation.


Assuntos
Músculo Esquelético , Espectroscopia de Luz Próxima ao Infravermelho , Masculino , Feminino , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Músculo Esquelético/fisiologia , Pandemias , Oxigênio/metabolismo , Hemodinâmica , Ultrassonografia , Ultrassonografia de Intervenção
4.
Biomed Opt Express ; 14(11): 5994-6015, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38021143

RESUMO

In this work, we used a hybrid time domain near-infrared spectroscopy (TD-NIRS) and diffuse correlation spectroscopy (DCS) device to retrieve hemoglobin and blood flow oscillations of skeletal muscle microvasculature. We focused on very low (VLF) and low-frequency (LF) oscillations (i.e., frequency lower than 0.145 Hz), that are related to myogenic, neurogenic and endothelial activities. We measured power spectral density (PSD) of blood flow and hemoglobin concentration in four muscles (thenar eminence, plantar fascia, sternocleidomastoid and forearm) of 14 healthy volunteers to highlight possible differences in microvascular hemodynamic oscillations. We observed larger PSDs for blood flow compared to hemoglobin concentration, in particular in case of distal muscles (i.e., thenar eminence and plantar fascia). Finally, we compared the PSDs measured on the thenar eminence of healthy subjects with the ones measured on a septic patient in the intensive care unit: lower power in the endothelial-dependent frequency band, and larger power in the myogenic ones were observed in the septic patient, in accordance with previous works based on laser doppler flowmetry.

5.
Neurophotonics ; 10(4): 045003, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37841558

RESUMO

Significance: Critically ill newborns are at risk of brain damage from cerebrovascular disturbances. A cerebral hemodynamic monitoring system would have the potential role to guide targeted intervention. Aim: To obtain, in a population of newborn infants, simultaneous near-infrared spectroscopy (NIRS)-based estimates of cerebral tissue oxygen saturation (StO2) and blood flow during variations of carbon dioxide tension (pCO2) levels within physiologic values up to moderate permissive hypercapnia, and to examine if the derived estimate of metabolic rate of oxygen would stay constant, during the same variations. Approach: We enrolled clinically stable mechanically ventilated newborns at postnatal age >24 h without brain abnormalities at ultrasound. StO2 and blood flow index were measured using a non-invasive device (BabyLux), which combine time-resolved NIRS and diffuse-correlation spectroscopy. The effect of changes in transcutaneous pCO2 on StO2, cerebral blood flow (CBF), and cerebral metabolic rate of oxygen index (tCMRO2i) were estimated. Results: Ten babies were enrolled and three were excluded. Median GA at enrollment was 39 weeks and median weight 2720 g. StO2 increased 0.58% (95% CI 0.55; 0.61, p<0.001), CBF 2% (1.9; 2.3, p<0.001), and tCMRO2 0.3% (0.05; 0.46, p=0.017) per mmHg increase in pCO2. Conclusions: BabyLux device detected pCO2-induced changes in cerebral StO2 and CBF, as expected. The small statistically significant positive relationship between pCO2 and tCMRO2i variation is not considered clinically relevant and we are inclined to consider it as an artifact.

6.
Neurophotonics ; 10(1): 015006, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36911206

RESUMO

Significance: The optical measurement of cerebral oxygen metabolism was evaluated. Aim: Compare optically derived cerebral signals to the electroencephalographic bispectral index (BIS) sensors to monitor propofol-induced anesthesia during surgery. Approach: Relative cerebral metabolic rate of oxygen ( rCMRO 2 ) and blood flow (rCBF) were measured by time-resolved and diffuse correlation spectroscopies. Changes were tested against the relative BIS (rBIS) ones. The synchronism in the changes was also assessed by the R-Pearson correlation. Results: In 23 measurements, optically derived signals showed significant changes in agreement with rBIS: during propofol induction, rBIS decreased by 67% [interquartile ranges (IQR) 62% to 71%], rCMRO 2 by 33% (IQR 18% to 46%), and rCBF by 28% (IQR 10% to 37%). During recovery, a significant increase was observed for rBIS (48%, IQR 38% to 55%), rCMRO 2 (29%, IQR 17% to 39%), and rCBF (30%, IQR 10% to 44%). The significance and direction of the changes subject-by-subject were tested: the coupling between the rBIS, rCMRO 2 , and rCBF was witnessed in the majority of the cases (14/18 and 12/18 for rCBF and 19/21 and 13/18 for rCMRO 2 in the initial and final part, respectively). These changes were also correlated in time ( R > 0.69 to R = 1 , p - values < 0.05 ). Conclusions: Optics can reliably monitor rCMRO 2 in such conditions.

7.
Biomed Opt Express ; 12(7): 4235-4248, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34457411

RESUMO

A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant changes in the systemic physiology that influence the muscle hemodynamics, we have observed that the high MVC group showed a 56% and 36% decrease in the blood flow during exercise, with respect to baseline, in the long and short source-detector (SD) separations (p=0.031 for both). No statistical differences were shown for the low MVC group (p=1 for short and p=0.15 for long SD). These results suggest that the mechanical occlusion, due to increased intramuscular pressure, exceeded the vasodilation elicited by the higher metabolic demand. Also, blood flow changes during thumb contraction negatively correlated (R=-0.7, p<0.01) with the absolute force applied by each subject. Furthermore, after the exercise, muscular blood flow increased significantly immediately after thumb contractions in both high and low MVC groups, with respect to the recorded values during the exercise (p=0.031). An increase of 251% (200%) was found for the long (short) SD in the low MVC group. The high MVC groups showed a significant 90% increase in blood flow only after 80 s from the start of the protocol. For both low and high MVC groups, blood flow recovered to baseline values within 160 s from starting the exercise. In conclusion, DCS allows the study of the response of a small muscle to static exercise and can be potentially used in multiple clinical conditions scenarios for assessing microvascular health.

8.
Biomed Opt Express ; 12(6): 3265-3281, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34221659

RESUMO

Over the recent years, a typical implementation of diffuse correlation spectroscopy (DCS) instrumentation has been adapted widely. However, there are no detailed and accepted recipes for designing such instrumentation to meet pre-defined signal-to-noise ratio (SNR) and precision targets. These require specific attention due to the subtleties of the DCS signals. Here, DCS experiments have been performed using liquid tissue simulating phantoms to study the effect of the detected photon count-rate, the number of parallel detection channels and the measurement duration on the precision and SNR to suggest scaling relations to be utilized for device design.

9.
Biomed Opt Express ; 12(6): 3392-3409, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34221667

RESUMO

We present the LUCA device, a multi-modal platform combining eight-wavelength near infrared time resolved spectroscopy, sixteen-channel diffuse correlation spectroscopy and a clinical ultrasound in a single device. By simultaneously measuring the tissue hemodynamics and performing ultrasound imaging, this platform aims to tackle the low specificity and sensitivity of the current thyroid cancer diagnosis techniques, improving the screening of thyroid nodules. Here, we show a detailed description of the device, components and modules. Furthermore, we show the device tests performed through well established protocols for phantom validation, and the performance assessment for in vivo. The characterization tests demonstrate that LUCA device is capable of performing high quality measurements, with a precision in determining in vivo tissue optical and dynamic properties of better than 3%, and a reproducibility of better than 10% after ultrasound-guided probe repositioning, even with low photon count-rates, making it suitable for a wide variety of clinical applications.

10.
J Neurotrauma ; 37(23): 2569-2579, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32460617

RESUMO

Intracranial pressure (ICP) is an important parameter to monitor in several neuropathologies. However, because current clinically accepted methods are invasive, its monitoring is limited to patients in critical conditions. On the other hand, there are other less critical conditions for which ICP monitoring could still be useful; therefore, there is a need to develop non-invasive methods. We propose a new method to estimate ICP based on the analysis of the non-invasive measurement of pulsatile, microvascular cerebral blood flow with diffuse correlation spectroscopy. This is achieved by training a recurrent neural network using only the cerebral blood flow as the input. The method is validated using a 50% split sample method using the data from a proof-of-concept study. The study involved a population of infants (n = 6) with external hydrocephalus (initially diagnosed as benign enlargement of subarachnoid spaces) as well as a population of adults (n = 6) with traumatic brain injury. The algorithm was applied to each cohort individually to obtain a model and an ICP estimate. In both diverse cohorts, the non-invasive estimation of ICP was achieved with an accuracy of <4 mm Hg and a negligible small bias. Further, we have achieved a good correlation (Pearson's correlation coefficient >0.9) and good concordance (Lin's concordance correlation coefficient >0.9) in comparison with standard clinical, invasive ICP monitoring. This preliminary work paves the way for further investigations of this tool for the non-invasive, bedside assessment of ICP.


Assuntos
Pressão Intracraniana , Redes Neurais de Computação , Monitorização Neurofisiológica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Circulação Cerebrovascular , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Hipertensão Intracraniana/diagnóstico , Masculino , Estudo de Prova de Conceito , Processamento de Sinais Assistido por Computador
11.
J Cereb Blood Flow Metab ; 40(10): 2055-2065, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31665953

RESUMO

Diffuse correlation spectroscopy (DCS) can non-invasively and continuously asses regional cerebral blood flow (rCBF) at the cot-side by measuring a blood flow index (BFI) in non-traditional units of cm2/s. We have validated DCS against positron emission tomography using 15O-labeled water (15O-water PET) in a piglet model allowing us to derive a conversion formula for BFI to rCBF in conventional units (ml/100g/min). Neonatal piglets were continuously monitored by the BabyLux device integrating DCS and time resolved near infrared spectroscopy (TRS) while acquiring 15O-water PET scans at baseline, after injection of acetazolamide and during induced hypoxic episodes. BFI by DCS was highly correlated with rCBF (R = 0.94, p < 0.001) by PET. A scaling factor of 0.89 (limits of agreement for individual measurement: 0.56, 1.39)×109× (ml/100g/min)/(cm2/s) was used to derive baseline rCBF from baseline BFI measurements of another group of piglets and of healthy newborn infants showing an agreement with expected values. These results pave the way towards non-invasive, cot-side absolute CBF measurements by DCS on neonates.


Assuntos
Circulação Cerebrovascular/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Acetazolamida/farmacologia , Animais , Animais Recém-Nascidos , Diuréticos/farmacologia , Humanos , Hipóxia/fisiopatologia , Processamento de Imagem Assistida por Computador , Recém-Nascido , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Suínos
12.
Biomed Opt Express ; 10(5): 2556-2579, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31149383

RESUMO

We have investigated the accuracy and precision of "the BabyLux device", a hybrid time-resolved near-infrared (TRS) and diffuse correlation spectroscopy (DCS) neuro-monitor for the pre-term infant. Numerical data with realistic noise were simulated and analyzed using the BabyLux device as a reference system and different experimental and analysis parameters. The results describe the limits for the precision and the accuracy to be expected. The dependence of these limits on different experimental conditions and choices of the analysis method is also described. Experiments demonstrate comparable values for precision with respect to the simulation results.

13.
Neurophotonics ; 6(2): 025007, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31093515

RESUMO

The BabyLux device is a hybrid diffuse optical neuromonitor that has been developed and built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring of microvascular cerebral blood flow and blood oxygenation. It integrates time-resolved near-infrared and diffuse correlation spectroscopies in a user-friendly device as a prototype for a future medical grade device. We present a thorough characterization of the device performance using test measurements in laboratory settings. Tests on solid phantoms report an accuracy of optical property estimation of about 10%, which is expected when using the photon diffusion equation as the model. The measurement of the optical and dynamic properties is stable during several hours of measurements within 3% of the average value. In addition, these measurements are repeatable between different days of measurement, showing a maximal variation of 5% in the optical properties and 8% for the particle diffusion coefficient on a liquid phantom. The variability over test/retest evaluation is < 3 % . The integration of the two modalities is robust and without any cross talk between the two. We also perform in vivo measurements on the adult forearm during arterial cuff occlusion to show that the device can measure a wide range of tissue hemodynamic parameters. We suggest that this platform can form the basis of the next-generation neonatal neuromonitors to be developed for extensive, multicenter clinical testing.

14.
Polymers (Basel) ; 11(3)2019 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-30960538

RESUMO

Ethylene-co-norbornene copolymers were synthesized by a dual catalyst system at three concentrations of norbornene in the feed and variable amounts of ZnEt2, as a possible chain transfer agent. The dual catalyst system consists of two ansa-metallocenes, isopropyliden(η5-cyclopentadienyl)(η5-indenyl)zirconium dichloride (1) and isopropyliden(η5-3-methylcyclopentadienyl)(η5-fluorenyl)zirconium dichloride (2), activated with dimethylanilinium tetrakis(pentafluorophenyl)borate, in presence of TIBA. Values of norbornene content, molecular mass, glass transition temperature, and reactivity ratios r11 and r21 of copolymers prepared in the presence of 1+2 are intermediate between those of reference copolymers. The study of tensile and elastic properties of ethylene-co-norbornene copolymers (poly(E-co-N)s) gave evidence that copolymers were obtained in part through transfer of polymer chains between different transition metal sites. Mechanical properties are clearly different from those expected from a blend of the parent samples and reveal that copolymers obtained in the presence of 1+2 and ZnEt2 consist of a reactor blend of segmented chains produced by exchange from 2 to 1 and 1 to 2 acting as the ideal compatibilizer of chains produced by the chain transfer from 1 to 1, and from 2 to 2.

15.
Biomed Opt Express ; 9(5): 2068-2080, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29760970

RESUMO

We present the recipe and characterization for preparing liquid phantoms that are suitable for both near-infrared spectroscopy and diffuse correlation spectroscopy. The phantoms have well-defined and tunable optical and dynamic properties, and consist of a solution of water and glycerol with fat emulsion as the scattering element. The recipe takes into account the effect of bulk refractive index changes due to the addition of glycerol, which is commonly used to alter the sample viscosity.

16.
Wien Klin Wochenschr ; 130(1-2): 45-53, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28733841

RESUMO

BACKGROUND: Analgesia and sedation are key items in intensive care. Recently published S3 guidelines specifically address treatment of patients with elevated intracranial pressure. METHODS: The Austrian Society of Anesthesiology, Resuscitation and Intensive Care Medicine carried out an online survey of neurointensive care units in Austria in order to evaluate the current state of practice in the areas of analgosedation and delirium management in this high-risk patient group. RESULTS: The response rate was 88%. Induction of anesthesia in patients with elevated intracranial pressure is carried out with propofol/fentanyl/rocuronium in >80% of the intensive care units (ICU), 60% use midazolam, 33.3% use esketamine, 13.3% use barbiturates and 6.7% use etomidate. For maintenance of analgosedation up to 72 h, propofol is used by 80% of the ICUs, followed by remifentanil (46.7%), sufentanil (40%) and fentanyl (6.7%). For long-term sedation, 86.7% of ICUs use midazolam, 73.3% sufentanil and 73.3% esketamine. For sedation periods longer than 7 days, 21.4% of ICUs use propofol. Reasons for discontinuing propofol are signs of rhabdomyolysis (92.9%), green urine, elevated liver enzymes (71.4% each) and elevated triglycerides (57.1%). Muscle relaxants are only used during invasive procedures. Inducing a barbiturate coma is rated as a last resort by 53.3% of respondents. The monitoring methods used are bispectral index (BIS™, 61.5% of ICUs), somatosensory-evoked potentials (SSEP, 53.8%), processed electroencephalography (EEG, 38.5%), intraparenchymal partial pressure of oxygen (pO2, 38.5%) and microdialysis (23.1%). Sedation and analgesia are scored using the Richmond agitation and sedation score (RASS, 86.7%), sedation agitation scale (SAS, 6.7%) or numeric rating scale (NRS, 50%) and behavioral pain scale (BPS, 42.9%), visual analogue scale (VAS), critical care pain observation tool (CCPOT, each 14.3%) and verbal rating scale (VRS, 7.1%). Delirium monitoring is done using the confusion assessment method for intensive care units (CAM-ICU, 46.2%) and intensive care delirium screening checklist (ICDSC, 7.7%). Of the ICUs 46.2% do not carry out delirium monitoring. CONCLUSION: We found good general compliance with the recommendations of the current S3 guidelines. Room for improvement exists in monitoring and the use of scores to detect delirium.


Assuntos
Hipnóticos e Sedativos , Unidades de Terapia Intensiva/normas , Hipertensão Intracraniana , Adulto , Áustria , Humanos , Hipnóticos e Sedativos/uso terapêutico , Hipertensão Intracraniana/terapia , Respiração Artificial , Inquéritos e Questionários
17.
Osteoarthritis Cartilage ; 24(7): 1284-91, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26915639

RESUMO

OBJECTIVE: In a rat monoiodoacetic acid (MIA)-induced arthritis model, the amount of MIA commonly used was too high, resulting in rapid bone destruction. We examined the effect of MIA concentrations on articular cartilage and infrapatellar fat pad (IFP). We also established an original system for "macroscopic cartilage and bone score" and "IFP inflammation score" specific to the rat MIA-induced arthritis model. DESIGN: Male Wistar rats received a single intra-articular injection of MIA in the knee. The amount of MIA was 0.1, 0.2, 0.5, and 1 mg respectively. Articular cartilage was evaluated at 2-12 weeks. IFP was also observed at 3-14 days. RESULTS: Macroscopically, low MIA doses induced punctate depressions on the cartilage surface, and cartilage erosion proceeded slowly over 12 weeks, while higher MIA doses already induced cartilage erosion at 2 weeks, followed by bone destruction. MIA macroscopic cartilage and bone score, OARSI histological score, and Mankin score increased in a dose- and time-dependent manner. The IFP inflammation score peaked at 5 days in low dose groups, then decreased, while in high dose groups, the IFP score continued to increase over 14 days due to IFP fibrosis. CONCLUSIONS: Punctate depressions, cartilage erosion, and bone destruction were observed in the MIA-induced arthritis model. The macroscopic cartilage and bone scoring enabled the quantification of cartilage degeneration and demonstrated that MIA-induced arthritis progressed in a dose- and time-dependent manner. IFP inflammation scores revealed that 0.2 mg MIA induced reversible synovitis, while 1 mg MIA induced fibrosis of the IFP body.


Assuntos
Sinovite , Animais , Cartilagem Articular , Injeções Intra-Articulares , Ácido Iodoacético , Masculino , Ratos , Ratos Wistar
18.
PLoS One ; 11(1): e0147851, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26815533

RESUMO

The in vivo optical and hemodynamic properties of the healthy (n = 22) and pathological (n = 2) human thyroid tissue were measured non-invasively using a custom time-resolved spectroscopy (TRS) and diffuse correlation spectroscopy (DCS) system. Medical ultrasound was used to guide the placement of the hand-held hybrid optical probe. TRS measured the absorption and reduced scattering coefficients (µa, µs') at three wavelengths (690, 785 and 830 nm) to derive total hemoglobin concentration (THC) and oxygen saturation (StO2). DCS measured the microvascular blood flow index (BFI). Their dependencies on physiological and clinical parameters and positions along the thyroid were investigated and compared to the surrounding sternocleidomastoid muscle. The THC in the thyroid ranged from 131.9 µM to 144.8 µM, showing a 25-44% increase compared to the surrounding sternocleidomastoid muscle tissue. The blood flow was significantly higher in the thyroid (BFIthyroid = 16.0 × 10-9 cm2/s) compared to the muscle (BFImuscle = 7.8 × 10-9 cm2/s), while StO2 showed a small (StO2, muscle = 63.8% to StO2, thyroid = 68.4%), yet significant difference. Two case studies with thyroid nodules underwent the same measurement protocol prior to thyroidectomy. Their THC and BFI reached values around 226.5 µM and 62.8 × 10-9 cm2/s respectively showing a clear contrast to the nodule-free thyroid tissue as well as the general population. The initial characterization of the healthy and pathologic human thyroid tissue lays the ground work for the future investigation on the use of diffuse optics in thyroid cancer screening.


Assuntos
Hemodinâmica , Glândula Tireoide/irrigação sanguínea , Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/irrigação sanguínea , Nódulo da Glândula Tireoide/patologia , Adulto , Feminino , Humanos , Masculino , Análise Espectral
19.
Opt Express ; 22(23): 28002-18, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402041

RESUMO

We present a new hardware simulator (HS) for characterization, testing and benchmarking of digital correlators used in various optical correlation spectroscopy experiments where the photon statistics is Gaussian and the corresponding time correlation function can have any arbitrary shape. Starting from the HS developed in [Rev. Sci. Instrum. 74, 4273 (2003)], and using the same I/O board (PCI-6534 National Instrument) mounted on a modern PC (Intel Core i7-CPU, 3.07GHz, 12GB RAM), we have realized an instrument capable of delivering continuous streams of TTL pulses over two channels, with a time resolution of Δt = 50ns, up to a maximum count rate of 〈I〉 ∼ 5MHz. Pulse streams, typically detected in dynamic light scattering and diffuse correlation spectroscopy experiments were generated and measured with a commercial hardware correlator obtaining measured correlation functions that match accurately the expected ones.


Assuntos
Algoritmos , Biometria/métodos , Fótons , Análise Espectral/instrumentação , Espectrometria de Fluorescência/instrumentação
20.
Transplant Proc ; 46(6): 1887-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25131061

RESUMO

BACKGROUND: Rhabdomyolysis is a syndrome characterized by impaired metabolic integrity of myocytes, causing the release of intracellular constituents into the circulation, and can be a serious side effect of drug intake. CASE REPORT: This report describes a unique case of rabdomyolysis secondary in which ciprofibrate, sirolimus, cyclosporine, and pegylated interferon-α in a liver transplant patient was used. A 47-year-old male liver transplant recipient in 2009, who had hepatitis C and incidental hepatocellular carcinoma, underwent immunosuppressive therapy (cyclosporine and sirolimus). The patient is currently in treatment for viral recurrence with pegylated interferon-α and ribavirin; he had a history of hypertriglyceridemia treated with ciprofibrate. He had development of severe and generalized myalgia and fever after the eighth application of pegylated interferon-α and increasing doses of cyclosporine. Laboratorial tests showed acute renal failure and significant increase in creatine kinase. Rhabdomyolysis secondary to interaction of fibrate-cyclosporine-pegylated interferon-α was postulated. CONCLUSIONS: Medical professionals should be aware of possible drug interactions and should monitor patients receiving these drugs.


Assuntos
Ciclosporina/efeitos adversos , Ácidos Fíbricos/efeitos adversos , Interferon-alfa/efeitos adversos , Transplante de Fígado , Rabdomiólise/induzido quimicamente , Sirolimo/efeitos adversos , Antivirais/uso terapêutico , Interações Medicamentosas , Quimioterapia Combinada , Hepatite C/tratamento farmacológico , Humanos , Imunossupressores , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis/uso terapêutico , Ribavirina/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...