Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 17(7): e012854, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38758741

RESUMO

BACKGROUND: Unlike conventional microsecond pulsed electrical fields that primarily target the cell membranes, nanosecond pulses are thought to primarily electroporate intracellular organelles. We conducted a comprehensive preclinical assessment of catheter-based endocardial nanosecond pulsed field ablation in swine. METHODS: A novel endocardial nanosecond pulsed field ablation system was evaluated in a total of 25 swine. Using either a low-dose (5-second duration) or high-dose (15-second duration) strategy, thoracic veins and discrete atrial and ventricular sites were ablated. Predetermined survival periods were <1 (n=1), ≈2 (n=7), ≈7 (n=6), 14 (n=2), or ≈28 (n=9) days, and venous isolation was assessed before euthanasia. Safety assessments included evaluation of esophageal effects, phrenic nerve function, and changes in venous caliber. All tissues were subject to careful gross pathological and histopathologic examination. RESULTS: All (100%) veins (13 low-dose, 34 high-dose) were acutely isolated, and all reassessed veins (6 low-dose, 15 high-dose) were durably isolated. All examined vein lesions (10 low-dose, 22 high-dose) were transmural. Vein diameters (n=15) were not significantly changed. Of the animals assessed for phrenic palsy (n=9), 3 (33%) demonstrated only transient palsy. There were no differences between dosing strategies. Thirteen mitral isthmus lesions were analyzed, and all 13 (100%) were transmural (depth, 6.4±0.4 mm). Ventricular lesions were 14.7±4.5 mm wide and 7.1±1.3 mm deep, with high-dose lesions deeper than low-dose (7.9±1.2 versus 6.2±0.8 mm; P=0.007). The esophagus revealed nontransmural adventitial surface lesions in 5 of 5 (100%) animals euthanized early (2 days) post-ablation. In the 10 animals euthanized later (14-28 days), all animals demonstrated significant esophageal healing-8 with complete resolution, and 2 with only trace fibrosis. CONCLUSIONS: A novel, endocardial nanosecond pulsed field ablation system provides acute and durable venous isolation and linear lesions. Transient phrenic injury and nontransmural esophageal lesions can occur with worst-case assessments suggesting limits to pulsed field ablation tissue selectivity and the need for dedicated assessments during clinical studies.


Assuntos
Estudos de Viabilidade , Nervo Frênico , Animais , Suínos , Fatores de Tempo , Miocárdio/patologia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Veias/fisiopatologia , Modelos Animais , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/patologia , Esôfago , Átrios do Coração/fisiopatologia , Átrios do Coração/patologia
2.
Circ Arrhythm Electrophysiol ; 15(10): e010668, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36194538

RESUMO

BACKGROUND: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. METHODS: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). RESULTS: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20-85] J versus 10 [IQR 10-11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations (P=0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P=0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10-46] J versus 129 [IQR 24-143] J, P=0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P=0.04). CONCLUSIONS: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.


Assuntos
Ablação por Cateter , Estenose Coronária , Vasoespasmo Coronário , Suínos , Animais , Vasos Coronários/cirurgia , Vasos Coronários/lesões , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estenose Coronária/cirurgia , Espasmo/patologia , Angiografia Coronária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...