1.
Magn Reson Imaging ; 71: 27-36, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32325234

RESUMO

The purpose of this study was to determine an optimal condition (vibration frequency and image filtering) for stiffness estimation with high accuracy and stiffness measurement with high repeatability in magnetic resonance elastography (MRE) of the supraspinatus muscle. Nine healthy volunteers underwent two MRE exams separated by at least a 30 min break, on the same day. MRE acquisitions were performed with a gradient-echo type multi-echo MR sequence at 75, 100, and 125 Hz pneumatic vibration. Wave images were processed by a bandpass filter or filter combining bandpass and directional filters (bandpass-directional filter). An observer specified the region of interest (ROI) on clear wave propagation in the supraspinatus muscle, within which the observer measured the stiffness. This study assessed wave image quality according to two indices, as a substitute for the assessment of the accuracy of the stiffness estimation. One is the size of the clear wave propagation area (ROI size used to measure the stiffness) and the other is the qualitative stiffness resolution score in that area. These measurements made by the observer were repeated twice at least one month apart after each MRE exam. This study assessed the intra-examiner and observer repeatability of the stiffness value, ROI size and resolution score in each combination of vibration frequency and image filter. Repeatability of the data was analyzed using the intraclass correlation coefficient (ICC) and 95% limits-of-agreement (LOA) in Bland-Altman analysis. The analyses on intra-examiner and observer repeatability of stiffness indicated that the ICC and 95% LOA were not varied greatly depending on vibration frequency and image filter (intra-examiner repeatability, ICC range, 0.79 to 0.88; 95% LOA range, ±23.95 to ±32.42%, intra-observer repeatability, ICC range, 0.98 to 1.00; 95% LOA range, ±5.10 to ±10.99%). In the analyses on intra-examiner repeatability of ROI size, ICCs were rather low (ranging from: 0.03 to 0.69) while 95% LOA was large in all the combinations of vibration frequency and image filter (ranging from: ±62.66 to ±83.33%). In the analyses on intra-observer repeatability of ROI size, ICCs were sufficiently high in the total combination of vibration frequency and image filter (ranging from 0.80 to 0.87) while the 95% LOAs were better (lower) in the bandpass-directional filter than the bandpass filter (bandpass directional filter vs. bandpass filter, ±28.81 vs. ±54.83% at 75 Hz; ±25.63 vs. ±37.83% at 100 Hz; ±34.51 vs. ±43.36% at 125 Hz). In the analyses on intra-examiner and observer repeatability of resolution score, the mean difference (bias) between the two exams (or observations) was significantly low and there was almost no difference across all the combinations of vibration frequency and image filter (range of bias: -0.11-0.11 and -0.17-0.00, respectively). Additionally, effects of vibration frequency and image filter on wave image quality (ROI size and resolution score) were assessed separately in each exam. Both mean ROI size and resolution score in the bandpass-directional filter were larger than those in the bandpass filter. Among the data in the bandpass-directional filter, mean ROI size was larger at 75 and 100 Hz, and mean resolution score was larger at 100 and 125 Hz. Taking into consideration with the results of repeatability and wave image quality, the present results suggest that optimal vibration frequency and image filter for MRE of the supraspinatus muscles is 100 Hz and bandpass-directional filter, respectively.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Músculos/diagnóstico por imagem , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Manguito Rotador/diagnóstico por imagem , Vibração
2.
Magn Reson Imaging ; 63: 85-92, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31425804

RESUMO

The present study aimed to develop vibration techniques for magnetic resonance (MR) elastography (MRE) of the psoas major muscle (PM). Seven healthy volunteers were included. MRE was performed with motion-encoding gradient (MEG)-less multi-echo MRE sequence, which allows clinicians to perform MRE using conventional MR imaging. In order to transmit mechanical vibration of the pneumatic type to the PM, a long narrow vibration pad was designed using a 3D printer, and the optimum vibration techniques were verified. The vibration pad was placed under the lower back, with the volunteers in the supine position. The results indicated that the PM vibrated well through the transmitted vibration from the lumbar spine, which suggests that the placement of a narrow vibration pad under the supine body, along the lumbar spine, allows the vibration of the PM. The shear modulus of the PM (n = 7) was 1.23 ±â€¯0.09 kPa (mean ±â€¯SEM) on the right side and 1.22 ±â€¯0.15 kPa on the left side, with no significant difference (t-test, P > 0.05). Increased stiffness of the muscle due to continuous local contraction may be an important cause of non-specific low back pain (LBP). The present vibration techniques for MRE of the PM provide a quantitative diagnostic tool for changes in muscle stiffness associated with non-specific LBP.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Dor Lombar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Contração Muscular/fisiologia , Músculos Psoas/diagnóstico por imagem , Vibração , Adulto , Técnicas de Imagem por Elasticidade/instrumentação , Voluntários Saudáveis , Humanos , Dor Lombar/fisiopatologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Impressão Tridimensional/instrumentação , Músculos Psoas/fisiologia , Adulto Jovem
3.
Artigo em Japonês | MEDLINE | ID: mdl-30890671

RESUMO

The purpose of this study was to investigate an influence of vibration waveform on magnetic resonance elastography (MRE). MRE is an innovative imaging technique for the non-invasive quantification of the elasticity of soft tissues through the direct visualization of propagating shear waves in vivo using a special phase-contrast magnetic resonance imaging sequence. Since the elasticity of soft tissue calculates from the wavelength of propagating shear waves, it is necessary to propagate sine-wave-shape shear wave at the target soft tissue. However, due to the various factors; i.e. overload of vibration generator, poor contact between imaging object and vibration pad, etc.; it may be difficult to generate a simple sine wave. This work was focused on change vibration waveforms; i.e. square wave, triangle wave, saw-tooth wave; which is induced by the various factors. Phantom experimental results demonstrated that when square and saw-tooth waveforms of 25 Hz vibration frequency, into the phantom, the waveform of propagating wave was not similar to sine waveform. It may influence on the MRE that in case of the waveforms has low frequency and square or saw-tooth like waveforms.


Assuntos
Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética , Vibração , Elasticidade , Imagens de Fantasmas
5.
Magn Reson Imaging ; 57: 95-102, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30465866

RESUMO

We developed a Magnetic Resonance elastography (MRE) technique using a conventional magnetic resonance imaging (MRI), which allows a simultaneous elastography of the supraspinatus and trapezius muscles, by designing a new wave transducer (vibration pad) and optimizing the mechanical vibration frequency. Five healthy volunteers underwent an MRE. In order to transmit the mechanical vibration (pneumatic vibration) to the supraspinatus and trapezius muscles, a new vibration pad was designed using a three-dimensional (3D) printer. The vibration pad was placed on the skin 2 cm medial and 2 cm cephalad the deltoid tubercle. MRE acquisition was performed with a multi-slice gradient-echo type multi-echo MR sequence, which allows MREs even in a conventional MRI; two oblique axial images of the supraspinatus and trapezius muscles were obtained simultaneously. Vibration frequencies were set at 50-150 Hz, with a 25 Hz step. Wave image quality in each frequency was analyzed using a phase-to-noise ratio (PNR) and clarity of propagating wave that was assessed by two readers qualitatively. In the supraspinatus muscle, the wave images were of good quality especially at frequencies >75 Hz. In the trapezius muscle, the wave images were of better quality at low frequencies (50 and 75 Hz) compared with high frequencies (100-150 Hz). The PNR of both muscles were higher at low frequencies. The mean stiffness in the trapezius muscle (7.26 ±â€¯2.13 kPa at 75 Hz) was larger than those in the supraspinatus muscle (4.16 ±â€¯0.50 kPa at 75 Hz). The results demonstrated that our MRE technique allows simultaneous assessment of the stiffness in the supraspinatus and trapezius muscles using a conventional MRI, and that optimal vibration frequency for simultaneous MRE of these muscles is 75 Hz. This technique provides a new means for early detection of abnormality in the shoulder.


Assuntos
Técnicas de Imagem por Elasticidade , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Músculos Superficiais do Dorso/diagnóstico por imagem , Adulto , Voluntários Saudáveis , Humanos , Masculino , Movimento (Física) , Impressão Tridimensional , Manguito Rotador/diagnóstico por imagem , Ombro , Razão Sinal-Ruído , Vibração , Adulto Jovem