Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38848033

RESUMO

PURPOSE: Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far. METHODS: We developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance. RESULTS: The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging. CONCLUSIONS: This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.

2.
Brain Spine ; 4: 102827, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38784126

RESUMO

Introduction: Elderly patients receiving lumbar fusion surgeries present with a higher risk profile, which necessitates a robust predictor of postoperative outcomes. The Red Distribution Width (RDW) is a preoperative routinely determined parameter that reflects the degree of heterogeneity of red blood cells. Thereby, RDW is associated with frailty in hospital-admitted patients. Research question: This study aims to elucidate the potential of RDW as a frailty biomarker predictive of prolonged hospital stays following elective mono-segmental fusion surgery in elderly patients. Material and methods: In this retrospective study, we included all patients with age over 75 years that were treated via lumbar single-level spinal fusion from 2015 to 2022 at our tertiary medical center. Prolonged length of stay (pLOS) was defined as a length ≥ the 3rd quartile of LOS of all included patients. Classical correlation analysis, Receiver-operating characteristic (ROC) and new machine learning algorithms) were used. Results: A total of 208 patients were included in the present study. The median age was 77 (IQR 75-80) years. The median LOS of the patients was 6 (IQR 5-8) days. The data shows a significant positive correlation between RDW and LOS. RDW is significantly enhanced in the pLOS group. New machine learning approaches with the imputation of multiple variables can enhance the performance to an AUC of 71%. Discussion and conclusion: RDW may serve as a predictor for a pLOS in elderly. These results are compelling because the determination of this frailty biomarker is routinely performed at hospital admission. An improved prognostication of LOS could enable healthcare systems to distribute constrained hospital resources efficiently, fostering evidence-based decision-making processes.

3.
J Imaging ; 10(4)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38667974

RESUMO

Mixed reality (MxR) enables the projection of virtual three-dimensional objects into the user's field of view via a head-mounted display (HMD). This phantom model study investigated three different workflows for navigated common femoral arterial (CFA) access and compared it to a conventional sonography-guided technique as a control. A total of 160 punctures were performed by 10 operators (5 experts and 5 non-experts). A successful CFA puncture was defined as puncture at the mid-level of the femoral head with the needle tip at the central lumen line in a 0° coronary insertion angle and a 45° sagittal insertion angle. Positional errors were quantified using cone-beam computed tomography following each attempt. Mixed effect modeling revealed that the distance from the needle entry site to the mid-level of the femoral head is significantly shorter for navigated techniques than for the control group. This highlights that three-dimensional visualization could increase the safety of CFA access. However, the navigated workflows are infrastructurally complex with limited usability and are associated with relevant cost. While navigated techniques appear as a potentially beneficial adjunct for safe CFA access, future developments should aim to reduce workflow complexity, avoid optical tracking systems, and offer more pragmatic methods of registration and instrument tracking.

4.
Langenbecks Arch Surg ; 409(1): 135, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38649506

RESUMO

OBJECTIVE: Endovascular repair is the preferred treatment for aortoiliac aneurysm, with preservation of at least one internal iliac artery recommended. This study aimed to assess pre-endovascular repair anatomical characteristics of aortoiliac aneurysm in patients from the Global Iliac Branch Study (GIBS, NCT05607277) to enhance selection criteria for iliac branch devices (IBD) and improve long-term outcomes. METHODS: Pre-treatment CT scans of 297 GIBS patients undergoing endovascular aneurysm repair were analyzed. Measurements included total iliac artery length, common iliac artery length, tortuosity index, common iliac artery splay angle, internal iliac artery stenosis, calcification score, and diameters in the device's landing zone. Statistical tests assessed differences in anatomical measurements and IBD-mediated internal iliac artery preservation. RESULTS: Left total iliac artery length was shorter than right (6.7 mm, P = .0019); right common iliac artery less tortuous (P = .0145). Males exhibited greater tortuosity in the left total iliac artery (P = .0475) and larger diameter in left internal iliac artery's landing zone (P = .0453). Preservation was more common on right (158 unilateral, 34 bilateral) than left (105 unilateral, 34 bilateral). There were 192 right-sided and 139 left-sided IBDs, with 318 IBDs in males and 13 in females. CONCLUSION: This study provides comprehensive pre-treatment iliac anatomy analysis in patients undergoing endovascular repair with IBDs, highlighting differences between sides and sexes. These findings could refine patient selection for IBD placement, potentially enhancing outcomes in aortoiliac aneurysm treatment. However, the limited number of females in the study underscores the need for further research to generalize findings across genders.


Assuntos
Procedimentos Endovasculares , Aneurisma Ilíaco , Humanos , Masculino , Feminino , Aneurisma Ilíaco/cirurgia , Aneurisma Ilíaco/diagnóstico por imagem , Idoso , Procedimentos Endovasculares/métodos , Pessoa de Meia-Idade , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Artéria Ilíaca/diagnóstico por imagem , Implante de Prótese Vascular/métodos , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
J Neurosurg ; 140(6): 1777-1784, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38277665

RESUMO

OBJECTIVE: Operative interposition of material between the trigeminal nerve and offending artery for surgical treatment of drug-resistant trigeminal neuralgia (TGN), following the Jannetta method, has been proven to be the most successful invasive treatment. Reexplorations of patients with recurrence of TGN have revealed nerve root irritations and scarring due to interposed material. To prevent these complications, modifications of microvascular decompression (MVD) aim at transposing the vessel away from the trigeminal nerve, without attachment of additional material to the nerve root. Given that both techniques (interposition and transposition) have been performed in the authors' institution, they decided to analyze them for the short- and midterm outcomes. METHODS: All patients who had undergone MVD for drug-resistant TGN in the authors' institution between 2008 and 2022 were analyzed retrospectively. Outcome at discharge and follow-up was evaluated using the Barrow Neurological Institute pain intensity score. Additionally, complications and pain recurrence were assessed. RESULTS: A total of 114 patients were operated on using transposition and 110 patients were treated using interposition. For transposition 102 patients were followed up for a median of 31.5 months, and for interposition 100 patients were followed up for a median of 95 months. At discharge 92.1% versus 94.5% of patients in the transposition and interposition groups, respectively, experienced a good outcome (Barrow Neurological Institute pain intensity scores I-III). At follow-up, 83.3% versus 85% of patients in the transposition and interposition groups, respectively, continued to demonstrate a good outcome. In 4.9% of patients in the transposition group and in 6% of patients in the interposition group, recurrence of pain occurred. Complications occurred in 24.6% of patients in the transposition and in 27.3% of those in the interposition group. The most frequent complications were facial hypesthesia (10.5% vs 11.8%, transposition vs interposition), followed by CSF leaks (2.6% vs 8.2%). CONCLUSIONS: Transposition for MVD is an elegant way of solving vessel-nerve conflicts at the cerebellopontine angle. Similar to interposition, transposition shows positive short- and midterm outcomes for patients experiencing drug-resistant TGN. However, the main objective of transposition, which is improved prevention of recurrence and reduction of complications at the trigeminal nerve, could not be confirmed in this study.


Assuntos
Cirurgia de Descompressão Microvascular , Neuralgia do Trigêmeo , Humanos , Neuralgia do Trigêmeo/cirurgia , Cirurgia de Descompressão Microvascular/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Adulto , Seguimentos , Nervo Trigêmeo/cirurgia , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Recidiva
6.
J Endovasc Ther ; : 15266028231208640, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37916479

RESUMO

PURPOSE: The purpose of this study was to investigate the technical feasibility and usability of a mixed reality (MiR)-assisted common femoral arterial (CFA) access technique using a sonography-assisted registration method. MATERIALS AND METHODS: A total of 60 CFA punctures were performed on a phantom model by 2 observers. Thirty punctures were performed using MiR (MiR group) and 30 punctures were performed using a conventional sonography-guided access procedure (control group). In the MiR group, a virtual object was created based on a computed tomography (CT) angiography scan of the model and registered to the physical patient in an MiR environment utilizing a software prototype that allowed registration based on a sonography scan. Positional error assessment encompassed 4 measurements using cone beam CT scans: (1) distance of the needle tip to the centerline, (2) distance of the needle entry site from the mid-level of the ostium of the profound femoral artery, (3) angle of entry of the needle in coronal, and (4) sagittal planes. Technical success rates as well as positional errors were compared between both groups. In addition, the usability of the system was assessed according to the system usability scale (SUS). RESULTS: Technical success was 96.7% and 100% in the MiR and control groups, respectively. The median distance between the needle tip and the centerline was 3.0 (interquartile range [IQR]: 2.0-4.6) in the MiR group and 3.2 mm (IQR: 2.3-3.9) (p=0.63) in the control group. Similarly, the median distance from the needle entry site to the mid-level of the ostium of the profound femoral artery was 3.0 mm (IQR: 2.0-5.0) in the MiR group and 4.5 mm (IQR: 2.0-7.8) (p=0.18) in the control group. The median coronal angles of needle entry were 7.5° (IQR: 6-11) and 6° (IQR: 2-12) (p=0.13), and the median sagittal angles were 50° (IQR: 47-51) and 51° (IQR: 50-55) (p<0.01) in the MiR and control groups, respectively. The mean SUS score provided by both observers was 51.3. CONCLUSION: The feasibility of an MiR-assisted CFA access technique could be demonstrated on a phantom model. Further studies are needed to investigate the technique beyond phantom model experiments and in different anatomical settings. CLINICAL IMPACT: This study demonstrates the technical feasibility of a Mixed-Reality-assisted common femoral arterial access procedure on a phantom model. The positional accuracy was comparable to a conventional sonography-guided technique. However, there are several limitations that need to be resolved prior to potential implementation into clinical practice. Further studies are needed to investigate its performance beyond phantom model experiments and the prototypical application requires further technical refinement to increase its usability.

7.
Int J Comput Assist Radiol Surg ; 18(9): 1735-1744, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37245181

RESUMO

PURPOSE: Endovascular intervention is the state-of-the-art treatment for common cardiovascular diseases, such as heart attack and stroke. Automation of the procedure may improve the working conditions of physicians and provide high-quality care to patients in remote areas, posing a major impact on overall treatment quality. However, this requires the adaption to individual patient anatomies, which currently poses an unsolved challenge. METHODS: This work investigates an endovascular guidewire controller architecture based on recurrent neural networks. The controller is evaluated in-silico on its ability to adapt to new vessel geometries when navigating through the aortic arch. The controller's generalization capabilities are examined by reducing the number of variations seen during training. For this purpose, an endovascular simulation environment is introduced, which allows guidewire navigation in a parametrizable aortic arch. RESULTS: The recurrent controller achieves a higher navigation success rate of 75.0% after 29,200 interventions compared to 71.6% after 156,800 interventions for a feedforward controller. Furthermore, the recurrent controller generalizes to previously unseen aortic arches and is robust towards size changes of the aortic arch. Being trained on 2048 aortic arch geometries gives the same results as being trained with full variation when evaluated on 1000 different geometries. For interpolation a gap of 30% of the scaling range and for extrapolation additional 10% of the scaling range can be navigated successfully. CONCLUSION: Adaption to new vessel geometries is essential in the navigation of endovascular instruments. Therefore, the intrinsic generalization to new vessel geometries poses an essential step towards autonomous endovascular robotics.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Stents , Procedimentos Endovasculares/métodos , Redes Neurais de Computação , Prótese Vascular , Resultado do Tratamento , Estudos Retrospectivos , Desenho de Prótese
8.
Vasa ; 52(3): 169-174, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36880201

RESUMO

Background: To report technical success as well as perioperative outcomes of patients who underwent endovascular aortic repair (EVAR) of penetrating abdominal aortic ulcers ≤35 mm in diameter (PAU). Patients and methods: The abdominal aortic aneurysm (AAA) quality registry of the German institute for vascular research (DIGG) was used to identify patients with standard EVAR for infrarenal PAU ≤35 mm between 1/1/2019 and 12/31/2021. Infectious, traumatic, inflammatory PAUs, PAUs associated with connective tissue disease, PAUs following aortic dissection as well as true aneurysms were excluded. Demographics, cardiovascular comorbidity, technical success as well as perioperative morbidity and mortality were determined. Results: Amongst 11 537 patients who underwent EVAR during the study period, 405 with PAU ≤35 mm were eligible from 95 participating hospitals across Germany (22% women, 20.5% octogenarians). The median aortic diameter was 30 mm (Interquartile range 27-33). Cardiovascular comorbidities were frequent with coronary artery disease (34.8%), chronic heart failure (30.9%), history of myocardial infarction (19.8%), hypertension (76.8%), diabetes (21.7%), smoking (20.8%), history of stroke (9.4%), symptomatic lower extremity peripheral arterial disease (20%), chronic kidney disease (10.4%) and chronic obstructive pulmonary disease (9.6%). Most patients were asymptomatic (89.9%). Among the symptomatic patients, 13 presented with distal embolization (3.2%) and 3 with contained ruptures (0.7%). Technical success of endovascular repair was 98.3%. Both, percutaneous (37.1%) or femoral cut-down access approaches (58.5%) were registered. Endoleaks of any type were present with type 1 (0.5%), type 2 (6.4%) and type 3 (0.3%) endoleaks. Overall mortality was 0.5%. Perioperative complications occurred in 12 patients (3.0%). Conclusions: According to this registry data, endovascular repair of PAU is technically feasible with acceptable perioperative outcomes, but further studies investigating mid- and long-term data are needed before invasive treatment of PAU disease in an elderly and comorbid patient population should be recommended.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Úlcera Aterosclerótica Penetrante , Idoso de 80 Anos ou mais , Humanos , Feminino , Idoso , Masculino , Endoleak/etiologia , Úlcera/diagnóstico por imagem , Úlcera/cirurgia , Úlcera/complicações , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Complicações Pós-Operatórias
9.
J Endovasc Ther ; : 15266028231157636, 2023 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-36869667

RESUMO

PURPOSE: To systematically review existing evidence on outcomes of endovascular repair of abdominal atherosclerotic penetrating aortic ulcers (PAUs). MATERIAL AND METHODS: Cochrane Central Registry of Registered Trials (CENTRAL), MEDLINE (via PubMed), and Web of Science databases were systematically searched. The systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis protocol (PRISMA-P 2020). The protocol was registered in the international registry of systematic reviews (PROSPERO CRD42022313404). Studies reporting on technical and clinical outcomes of endovascular PAU repair in 3 or more patients were included. Random effects modeling was used to estimate pooled technical success, survival, reinterventions, and type 1 and type 3 endoleaks. Statistical heterogeneity was assessed using the I2 statistic. Pooled results are reported with 95% confidence intervals (CIs). Study quality was assessed using an adapted version of the Modified Coleman Methodology Score. RESULTS: Sixteen studies including 165 patients with a mean/median age ranging from 64 to 78 years receiving endovascular therapy for PAU between 1997 and 2020 were identified. Pooled technical success was 99.0% (CI: 96.0%-100%). In all, 30-day mortality was 1.0% (CI: 0%-6.0%) with an in-hospital mortality of 1.0% (CI: 0.0%-13.0%). There were no reinterventions, type 1, or type 3 endoleaks at 30 days. Median/mean follow-up ranged from 1 to 33 months. Overall, there were 16 deaths (9.7%), 5 reinterventions (3.3%), 3 type 1 (1.8%), and 1 type 3 endoleak (0.6%) during follow-up. The quality of studies was rated low according to the Modified Coleman score at 43.4 (+/- 8.5) of 85 points. CONCLUSION: There is low-level evidence on outcomes of endovascular PAU repair. While in the short-term endovascular repair of abdominal PAU seems safe and effective, mid-term and long-term data are lacking. Recommendations with regard to treatment indications and techniques in asymptomatic PAU should be made cautiously. CLINICAL IMPACT: This systematic review demonstrated that evidence on outcomes of endovascular abdominal PAU repair is limited. While in the short-term endovascular repair of abdominal PAU seems safe and effective, mid-term and long-term data are lacking. In the context of a benign prognosis of asymptomatic PAU and lacking standardization in current reporting, recommendations with regard to treatment indications and techniques in asymptomatic PAUs should be made cautiously.

10.
Vasa ; 52(3): 160-168, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36891667

RESUMO

Background: To investigate the usability of Mixed-Reality (MR) during patient education in patients scheduled for abdominal aortic aneurysm (AAA) repair. Patients and methods: Consecutive patients scheduled for elective AAA repair were block-randomized in either the Mixed-Reality group (MR group) or the conventional group (control group). Patients of both groups were educated about open and endovascular repair of their respective AAA. The MR group was educated using a head-mounted display (HMD) demonstrating a three-dimensional virtual reconstruction of the respective patient's vascular anatomy. The control group was educated using a conventional two-dimensional monitor to display the patient's vasculature. Outcomes were informational gain as well as patient satisfaction with the educational process. (DRKS-ID: DRKS00025174). Results: 50 patients were included with 25 patients in either group. Both groups demonstrated improvements in scores in the Informational Gain Questionnaire (IGQ) when comparing pre- and post-education scores. (MR group: 6.5 points (±1.8) versus 7.9 points (±1.5); Control group: 6.2 points (±1.8) versus 7.6 points (±1.6); p<0.01) There was no significant difference between the MR group and the control group either in informational gain (MR group: 1.4±1.8; Control group: 1.4±1.8; p=0.5) nor in patient satisfaction scores (MR group: mean 18.3 of maximum 21 points (±3.7); Control group: mean 17 of 21 points (±3.6); p=0.1) Multiple regression revealed no correlation between the use of MR and informational gain or patient satisfaction. Usability of the system was rated high, and patients' subjective assessment of MR was positive. Conclusions: The use of MR in patient education of AAA patients scheduled for elective repair is feasible. While patients reported positively on the use of MR in education, similar levels of informational gain and patient satisfaction can be achieved with MR and conventional methods.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Educação de Pacientes como Assunto , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
11.
Vasa ; 52(4): 218-223, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36734257

RESUMO

Background: To determine the adherence to supervised exercise training and underlying reasons for non-adherence amongst patients with inpatient treatment of symptomatic lower extremity peripheral arterial disease (PAD). Patients and methods: This was a prospective questionnaire-based survey study of all consecutively treated inpatients with treatment for either intermittent claudication or chronic limb-threatening ischaemia (CLTI) surveyed at sixteen participating centres in Germany. Results: A total of 235 patients (median age 70 years) were included, thereof 29.4% females and 34.6% with CLTI. The median time from first PAD diagnosis was 4 years (IQR: 1-8). Only 11.4% have previously participated in any walking exercise programme before the index treatment, thereby 10.0% in the IC subgroup and 12.0% with CLTI. Amongst all patients, 35.6% responded they were appropriately informed about the necessity and benefits of walking exercise programmes by their hospital physicians (25.8% by general practitioners), and 65.3% agreed that adherence to supervised exercise may improve their pain-free walking distance. A total of 24.5% responded they had access to necessary information concerning local walking exercise programmes. Amongst 127 free text comments on the reasons for non-adherence to supervised exercise training, 64% of the comments contained lack of information or consent on such measures. Conclusions: Less than 12% of the patients enrolled in the current study have ever participated in a walking exercise programme during their life course. Although all practice guidelines contain corresponding class I recommendations, especially for patients suffering from IC, most patients responded that they were not appropriately informed about the necessity of exercise training along with the fact that 65% agreed that exercise may increase the pain-free walking distance. Taken all together, these results emphasise that we miss an important opportunity in the patient-physician communication. Efforts should be made to improve acceptance and application of structured walking-exercise for patients with PAD.


Assuntos
Pacientes Internados , Doença Arterial Periférica , Feminino , Humanos , Idoso , Masculino , Estudos Prospectivos , Terapia por Exercício/métodos , Caminhada , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/terapia , Exercício Físico , Claudicação Intermitente/diagnóstico , Claudicação Intermitente/terapia , Inquéritos e Questionários
12.
J Endovasc Ther ; 30(3): 372-381, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35236157

RESUMO

PURPOSE: To determine the evolution of abdominal aortic aneurysm (AAA) diameter in the presence of persisting type 2 endoleaks (pEL2) following endovascular abdominal aortic aneurysm repair (EVAR). MATERIALS AND METHODS: This is a retrospective, single-center, case-control study. All patients with pEL2 (pEL2 group, persisting for > 12 months) between 2004 and 2018 were identified and compared with a 1:1 age- and gender-matched control with no endoleak (control group). Primary outcome measures were freedom from AAA expansion and freedom from AAA shrinkage over time. AAA diameter measurements were performed on computed tomography angiography (CTA). Secondary outcome measures were survival, AAA-related mortality, reinterventions for pEL2, incidence of secondary type 1 endoleaks (EL1), and infrarenal aortic branch vessel anatomy. RESULTS: A total of 773 patients were treated with EVAR for AAA between 2004 and 2018. Of them, 286 patients demonstrated type 2 endoleaks (EL2) in postoperative CTA or intraoperative angiography (37%). Forty-five of 286 EL2 (15.7%) were pEL2 (pEL2 group). Freedom from AAA expansion in the pEL2 group was 100%, 96.7%, 85.2%, and 54.3% after 1, 2, 3, and 4 years, respectively, compared with 100% after 1, 2, 3, and 4 years in the control group (p<0.01). Freedom from AAA shrinkage in the pEL2 group after 1, 2, 3, and 4 years was 95.5%, 90.4%, 90.4%, and 79.1%, respectively, compared with 86.7%, 34.8%, 19.3%, and 19.3% in the control group (p<0.01). Overall survival at 1, 2, 3, and 4 years was 100%, 97.6%, 95.0% and 95.0% in the pEL2 group and 100% at 1, 2, 3, and 4 years in the control group (p=0.17). There were no AAA-related deaths in either group. Patients with pEL2 had a significantly increased number of infrarenal aortic branches (p<0.05, respectively). Eighteen patients (40.0%) in the pEL2 group underwent 34 reinterventions for pEL2, with a median follow-up (FU) of 925 days (0-4173). Clinical success was achieved in 9 patients (50.0%). Four patients (8.9%) with pEL2 developed secondary EL1 after a median FU of 1278 days (662-2121). CONCLUSION: pEL2 are associated with AAA expansion during midterm FU. Further studies are warranted to evaluate the association of AAA expansion due to pEL2 with clinical outcomes to allow recommendations with regard to treatment indications.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Estudos de Casos e Controles , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Fatores de Risco
13.
Vascular ; 31(4): 644-653, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35404720

RESUMO

OBJECTIVES: The objective is to evaluate the feasibility and interobserver agreement of a Mixed Reality Viewer (MRV) in the assessment of aortoiliac vascular anatomy of abdominal aortic aneurysm (AAA) patients. METHODS: Fifty preoperative computed tomography angiographies (CTAs) of AAA patients were included. CTAs were assessed in a mixed reality (MR) environment with respect to aortoiliac anatomy according to a standardized protocol by two experienced observers (Mixed Reality Viewer, MRV, Brainlab AG, Germany). Additionally, all CTAs were independently assessed applying the same protocol by the same observers using a conventional DICOM viewer on a two-dimensional screen with multi-planar reconstructions (Conventional viewer, CV, GE Centricity PACS RA1000 Workstation, GE, United States). The protocol included four sets of items: calcification, dilatation, patency, and tortuosity as well as the number of lumbar and renal arteries. Interobserver agreement (IA, Cohen's Kappa, κ) was calculated for every item set. RESULTS: All CTAs could successfully be displayed in the MRV (100%). The MRV demonstrated equal or better IA in the assessment of anterior and posterior calcification (κMRV: 0.68 and 0.61, κCV: 0.33 and 0.45, respectively) as well as tortuosity (κMRV: 0.60, κCV: 0.48) and dilatation (κMRV: 0.68, κCV: 0.67). The CV demonstrated better IA in the assessment of patency (κMRV: 0.74, κCV: 0.93). The CV also identified significantly more lumbar arteries (CV: 379, MRV: 239, p < 0.01). CONCLUSIONS: The MRV is a feasible imaging viewing technology in clinical routine. Future efforts should aim at improving hologram quality and enabling accurate registration of the hologram with the physical patient.


Assuntos
Aneurisma da Aorta Abdominal , Realidade Aumentada , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Variações Dependentes do Observador , Estudos de Viabilidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Estudos Retrospectivos
14.
J Neurosurg Sci ; 67(1): 36-45, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36082834

RESUMO

INTRODUCTION: Surgical treatment for trigeminal neuralgia (TGN), by means of interposition of material between nerve and offending vessel, has been shown to be highly efficient. In recent years, treatment by means of vessel transposition has become more frequent, as in singular cases of recurrence, nerval reactions towards interposed material have been noted. In this review we research the classic microvascular decompression (MVD) techniques (interposition) as well as the more recent transposition and their effectiveness, considering patient outcomes as well as complications and recurrences. EVIDENCE ACQUISITION: We searched online databases MEDLINE and LIVIVO, using key words trigeminal neuralgia AND transposition/ AND sling/ AND non compressive technique/ AND microvascular decompression. EVIDENCE SYNTHESIS: We included 8 studies for transposition and 20 studies for the interposition, combining for 2045 patients (302 for transposition and 1743 for interposition). 96.1% of patients in the transposition and 93.1% in the interposition group reported a positive outcome immediately postoperatively. At follow-up, 87.4% in the transposition group (follow-up 51.2 months) and 87.9% of patients in the interposition group (follow-up 36.5 months), reported a positive outcome. 16.2% of patients in the transposition and 13.1% in the interposition group had postoperative complications. Recurrence was reported in 5.6% of patients treated with transposition and 2.3% of patients treated with interposition. CONCLUSIONS: Transposition presents similar results concerning short- and long-term patient satisfaction for treatment of TGN as well as similar numbers of complications of recurrences as interposition. Yet, current evidence is restricted to a few retrospective studies, thus, evidence is limited so far.


Assuntos
Cirurgia de Descompressão Microvascular , Neuralgia do Trigêmeo , Humanos , Neuralgia do Trigêmeo/cirurgia , Estudos Retrospectivos , Cirurgia de Descompressão Microvascular/métodos , Complicações Pós-Operatórias/cirurgia , Resultado do Tratamento , Nervo Trigêmeo/cirurgia
15.
Zentralbl Chir ; 147(5): 439-446, 2022 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-36220066

RESUMO

BACKGROUND: "Mixed reality" (MR) allows the projection of virtual objects into the user's field of view through a head-mounted display (HMD). In the interventional and surgical treatment of vascular diseases MR applications could be of future benefit. The following scoping review aims to provide orientation on the current application of the aforementioned technologies in the field of vascular surgery and to define research goals for the future. METHODS: A systematic literature search was performed in PubMed (MEDLINE) using the search terms "aorta", "intervention", "endovascular intervention", "vascular surgery", "aneurysm", "endovascular", "vascular access", each in combination with "mixed reality" or "augmented reality". The search was performed according to PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines for scoping reviews. RESULTS: From 547 references 8 relevant studies were identified. The search results could be classified into two categories: (1) MR aimed at information management and improving periprocedural ergonomics (n = 3) and (2) MR aimed at intraoperative navigation (n = 5). The registration of the physical patient with the virtual object and the tracking of instruments in the MR environment for intraoperative navigation is currently the focus of scientific interest and could be demonstrated on phantom and animal models with technical success. However, the methods presented so far are associated with high infrastructural costs and important limitations. CONCLUSION: The use of MR in the field of vascular surgery is promising. For the future, alternative, pragmatic registration methods with appropriate quantification of the positional error should be aimed at. The developed software and hardware solutions should be adapted to the requirements of vascular surgery. Electromagnetic instrument tracking appears to be a useful complementary technology for the implementation of MR-assisted navigation.


Assuntos
Cirurgia Assistida por Computador , Animais , Software , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Vasculares
17.
Eur J Neurol ; 29(10): 3009-3016, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35726716

RESUMO

BACKGROUND AND PURPOSE: In recent decades, the global incidence of aneurysmal subarachnoid hemorrhage (aSAH) has declined. However, significant regional differences exist. We present the first comprehensive analysis of time trends in the incidence of aSAH and case fatality in Germany. METHODS: All patients hospitalized with aSAH in Germany between 2005 and 2018 were identified using International Classification of Disease, 10th Revision codes I60.0-I60.7. RESULTS: A total of 101,105 cases were included. The incidence of aSAH in Germany decreased at a mean annual rate of 0.5% (p = 0.003) from 8.9 per 100,000 population in 2005 to 8.2 in 2018. Over time, incidences of aSAH declined among patients younger than 55 years and patients aged 70-79 years, increased among ages 60-64 years, and remained stable in age groups 65-69 and 85-89 years. This corresponded to an increase in the mean age of aSAH onset from 55.6 (±14.3) to 59.0 (±14.0) years. Throughout the study period, the mean age of aSAH onset was higher in women compared to men (58.3 ± 14.4 years vs. 56.1 ± 14.1 years). There were no changes in in-hospital case fatality (16.2 vs. 16.6%, p = 0.18), but the duration of hospital stay increased significantly from 19.7 to 24.8 days (p < 0.001). The most frequent aSAH-associated aneurysm location was the anterior circulation throughout the entire study period. CONCLUSIONS: In Germany, the incidence of aSAH decreased between 2005 and 2018, especially in younger parts of the population. This may reflect effects of lifestyle adjustments most pronounced in younger age groups.


Assuntos
Hemorragia Subaracnóidea , Adulto , Idoso , Feminino , Alemanha/epidemiologia , Hospitalização , Humanos , Incidência , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Hemorragia Subaracnóidea/epidemiologia
18.
Int J Comput Assist Radiol Surg ; 17(11): 2033-2040, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35604490

RESUMO

PURPOSE: The navigation of endovascular guidewires is a dexterous task where physicians and patients can benefit from automation. Machine learning-based controllers are promising to help master this task. However, human-generated training data are scarce and resource-intensive to generate. We investigate if a neural network-based controller trained without human-generated data can learn human-like behaviors. METHODS: We trained and evaluated a neural network-based controller via deep reinforcement learning in a finite element simulation to navigate the venous system of a porcine liver without human-generated data. The behavior is compared to manual expert navigation, and real-world transferability is evaluated. RESULTS: The controller achieves a success rate of 100% in simulation. The controller applies a wiggling behavior, where the guidewire tip is continuously rotated alternately clockwise and counterclockwise like the human expert applies. In the ex vivo porcine liver, the success rate drops to 30%, because either the wrong branch is probed, or the guidewire becomes entangled. CONCLUSION: In this work, we prove that a learning-based controller is capable of learning human-like guidewire navigation behavior without human-generated data, therefore, mitigating the requirement to produce resource-intensive human-generated training data. Limitations are the restriction to one vessel geometry, the neglected safeness of navigation, and the reduced transferability to the real world.


Assuntos
Aprendizado de Máquina , Redes Neurais de Computação , Animais , Simulação por Computador , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Suínos
19.
Gefasschirurgie ; 27(3): 208-212, 2022.
Artigo em Alemão | MEDLINE | ID: mdl-35291723

RESUMO

Although patients with peripheral arterial disease (PAD) are at a high risk of major bleeding owing to their comorbidity and risk profile, no validated tools exist to predict bleeding risk. To make matters worse, several randomized and controlled trials have excluded patients who are at a high risk of bleeding. Using routine health insurance claims data and machine learning methods, a pragmatic prediction model was developed and internally validated. The OAC3-PAD risk score identified eight variables that can predict major bleeding events within 1 year of inpatient treatment for PAD. This risk score can help to carry out a tailored patient-centered risk-benefit assessment in order to obtain the maximum potential from available antithrombotic treatment strategies.

20.
J Imaging ; 8(2)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35200749

RESUMO

Percutaneous femoral arterial access is daily practice in a variety of medical specialties and enables physicians worldwide to perform endovascular interventions. The reported incidence of percutaneous femoral arterial access complications is 3-18% and often results from suboptimal puncture location due to insufficient visualization of the target vessel. The purpose of this proof-of-concept study was to evaluate the feasibility and the positional error of a mixed-reality (MR)-assisted puncture of the common femoral artery in a phantom model using a commercially available navigation system. In total, 15 MR-assisted punctures were performed. Cone-beam computed tomography angiography (CTA) was used following each puncture to allow quantification of positional error of needle placements in the axial and sagittal planes. Technical success was achieved in 14/15 cases (93.3%) with a median axial positional error of 1.0 mm (IQR 1.3) and a median sagittal positional error of 1.1 mm (IQR 1.6). The median duration of the registration process and needle insertion was 2 min (IQR 1.0). MR-assisted puncture of the common femoral artery is feasible with acceptable positional errors in a phantom model. Future studies should aim to measure and reduce the positional error resulting from MR registration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...