Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38460161

RESUMO

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Assuntos
Reestenose Coronária , Infarto do Miocárdio , Feminino , Humanos , Idoso , Paclitaxel , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents , Resultado do Tratamento , Morte
3.
Cardiovasc Interv Ther ; 39(1): 47-56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37642826

RESUMO

The Agent device consists of a semi-compliant balloon catheter, which is coated with a therapeutic low-dose formulation of paclitaxel (2 µg/mm2) blended with an inactive excipient acetyl-tri-n-butyl citrate (ATBC). AGENT Japan SV is a randomized controlled study that enrolled 150 patients from 14 Japanese sites treated with Agent or SeQuent Please paclitaxel-coated balloon. This study also includes a single-arm substudy evaluating the safety and effectiveness of Agent in patients with in-stent restenosis (ISR). Patients with a single de novo native lesion (lesion length ≤ 28 mm and reference diameter ≥ 2.00 to < 3.00 mm) were randomized 2:1 to receive either Agent (n = 101) or SeQuent Please (n = 49). The ISR substudy enrolled 30 patients with lesion length ≤ 28 mm and reference diameter ≥ 2.00 to ≤ 4.00 mm. In the SV RCT, target lesion failure (TLF) at 1 year occurred in four patients treated with Agent (4.0%) versus one patient with SeQuent Please (2.0%; P = 1.00). None of the patients in either treatment arm died. There were no significant differences in the rates of myocardial infarction, target lesion revascularization and target lesion thrombosis through 1 year. In the ISR substudy, the 1-year rates of TLF and target lesion thrombosis were 6.7% and 0.0%, respectively. These data support the safety and effectiveness of the Agent paclitaxel-coated balloon in patients with small vessels and ISR.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Trombose , Humanos , Paclitaxel/farmacologia , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Resultado do Tratamento , Fatores de Risco , Trombose/etiologia , Materiais Revestidos Biocompatíveis
4.
JMIR Form Res ; 7: e45061, 2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37115658

RESUMO

BACKGROUND: African American individuals are at a higher risk of premature death from cardiovascular diseases than White American individuals, with disproportionate attributable risk from uncontrolled hypertension. Given their high use among African American individuals, mobile technologies, including smartphones, show promise in increasing reliable health information access. Culturally tailored mobile health (mHealth) interventions may promote hypertension self-management among this population. OBJECTIVE: This formative study aimed to assess the feasibility of integrating an innovative mHealth intervention into clinical and community settings to improve blood pressure (BP) control among African American patients. METHODS: A mixed methods study of African American patients with uncontrolled hypertension was conducted over 2 consecutive phases. In phase 1, patients and clinicians from 2 federally qualified health centers (FQHCs) in the Minneapolis-St Paul, Minnesota area, provided input through focus groups to refine an existing culturally tailored mHealth app (Fostering African-American Improvement in Total Health! [FAITH!] App) for promoting hypertension self-management among African American patients with uncontrolled hypertension (renamed as FAITH! Hypertension App). Phase 2 was a single-arm pre-post intervention pilot study assessing feasibility and patient satisfaction. Patients receiving care at an FQHC participated in a 10-week intervention using the FAITH! Hypertension App synchronized with a wireless BP monitor and community health worker (CHW) support to address social determinants of health-related social needs. The multimedia app consisted of a 10-module educational series focused on hypertension and cardiovascular risk factors with interactive self-assessments, medication and BP self-monitoring, and social networking. Primary outcomes were feasibility (app engagement and satisfaction) and preliminary efficacy (change in BP) at an immediate postintervention assessment. RESULTS: In phase 1, thirteen African American patients (n=9, 69% aged ≥50 years and n=10, 77% women) and 16 clinicians (n=11, 69% aged ≥50 years; n=14, 88% women; and n=10, 63% African American) participated in focus groups. Their feedback informed app modifications, including the addition of BP and medication tracking, BP self-care task reminders, and culturally sensitive contexts. In phase 2, sixteen African American patients were enrolled (mean age 52.6, SD 12.3 years; 12/16, 75% women). Overall, 38% (6/16) completed ≥50% of the 10 education modules, and 44% (7/16) completed the postintervention assessment. These patients rated the intervention a 9 (out of 10) on its helpfulness in hypertension self-management. Qualitative data revealed that they viewed the app as user-friendly, engaging, and informative, and CHWs were perceived as providing accountability and support. The mean systolic and diastolic BPs of the 7 patients decreased by 6.5 mm Hg (P=.15) and 2.8 mm Hg (P=.78), respectively, at the immediate postintervention assessment. CONCLUSIONS: A culturally tailored mHealth app reinforced by CHW support may improve hypertension self-management among underresourced African American individuals receiving care at FQHCs. A future randomized efficacy trial of this intervention is warranted. TRIAL REGISTRATION: ClinicalTrials.gov NCT04554147; https://clinicaltrials.gov/ct2/show/NCT04554147.

5.
Circ J ; 87(2): 287-295, 2023 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-36450540

RESUMO

BACKGROUND: Drug-coated balloons (DCB) have shown promising results for the treatment of in-stent restenosis (ISR) and small vessel disease (SVD). However, data comparing the treatment efficacy of different DCBs are limited.Methods and Results: AGENT Japan is a prospective randomized controlled trial that compares the Agent balloon coated with a low-dose formulation of paclitaxel (2 µg/mm2) to the SeQuent Please paclitaxel-coated balloon (3 µg/mm2) for the treatment of SVD. Patients with target lesion length ≤28 mm and reference diameter between ≥2.00 and <3.00 mm were randomized 2 : 1 for treatment with Agent (n=101) or SeQuent Please (n=49). This trial also includes a separate single-arm substudy evaluating the clinical safety and effectiveness of Agent in patients with ISR. The primary endpoint of 6-month target lesion failure (TLF) was observed in 3.0% of Agent and 0.0% of SeQuent Please patients (difference=3.0%; 97.5% upper confidence bound [UCB]=9.57%, which is less than the prespecified margin of 13.2%; Pnon-inferiority=0.0012). There were no deaths or thrombosis, and angiographic and quality-of-life outcomes were comparable between groups. The AGENT Japan ISR substudy (n=30) primary endpoint was met because the one-sided 97.5% UCB for 6-month TLF (3.3%) was significantly less than the study success criterion of 15.1% (97.5% UCB=9.8%; P<0.0001). CONCLUSIONS: Data from this study demonstrate good clinical outcomes with the Agent DCB when used to treat patients with SVD or ISR.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Stents Farmacológicos , Paclitaxel , Humanos , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Paclitaxel/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-38469035

RESUMO

Background: How diabetes mellitus (DM), race/ethnicity, and sex impact ischemic events following coronary artery stent procedures is unknown. Methods: Using the PLATINUM Diversity and PROMUS Element Plus Post-Approval Pooled Study (N = 4184), we examined the impact of race/ethnicity, sex, and DM on coronary stent outcomes. Primary outcome was 1-year major adverse cardiac events (MACE) (MACE composite: death, myocardial infarction [MI], and target vessel revascularization). Results: The study sample included 1437 diabetic patients (501 White men, 470 White women, 246 minority men, 220 minority women) and 2641 patients without medically treated DM (561 minority, 1090 women). Mean age (years) ranged from 61 in minority men to 65 in White women. Diabetic patients had a higher prevalence of atherosclerotic risk factors and comorbidities. Diabetic minority women (DMW; 70% Black, 27% Hispanic) had similar atherosclerotic risk factors to other diabetics, but experienced higher 1-year MACE (14.4% vs 7.5%, P <.01) and MI (4.3% vs 1.6%, P <.01) rates compared with patients without medically treated DM. No other diabetic cohort (White men, White women, minority men) showed an increased risk of MACE vs patients without medically treated DM. The incremental risk of MACE in DMW was associated with insulin use and persisted after risk adjustment (adjusted odds ratio 1.6 vs patients without medically treated DM; 95% CI, 1.0-2.5). Independent predictors of 1-year MACE included insulin use, hyperlipidemia, renal disease, and prior MI. Conclusions: DMW face the highest risk of ischemic events following coronary stenting, driven, in part, by insulin use. Aggressive secondary prevention and strict glycemic control are imperative in this cohort, and further research is warranted to elucidate the biologic mechanisms underpinning these observations. Clinical Trial Registration: NCT02240810 (http://clinicaltrials.gov/).

7.
Catheter Cardiovasc Interv ; 99(2): 373-380, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34051049

RESUMO

OBJECTIVES: The EVOLVE 48 study evaluated the safety and effectiveness of the SYNERGY 48 mm stent for the treatment of long lesions. BACKGROUND: Clinical evidence supporting the use of very long stents during percutaneous coronary intervention (PCI) is limited. The bioabsorbable polymer SYNERGY stent has shown good long-term data in a broad population of patients undergoing PCI. METHODS: Patients with lesion length >34- ≤44 mm and reference vessel diameter (RVD) ≥2.5- ≤ 4.0 mm were enrolled in this prospective, multicenter, single-arm study. The primary endpoint was 12-month target lesion failure (TLF; composite of target lesion revascularization [TLR], target-vessel myocardial infarction [TV-MI], or cardiac death) compared to a prespecified performance goal (PG). RESULTS: A total of 100 patients with mean lesion length of 35.34 ± 7.15 mm (26 patients with lesion length > 40 mm) and mean RVD 2.72 ± 0.44 mm were enrolled. Moderate to severe calcification was present in 30% of the patients and 89% had pre-TIMI flow grade 3. The rates of technical and clinical procedural success were 100%. One-year TLF was observed in 4.1% patients compared to a prespecified PG of 19.5% (95% upper confidence bound = 9.1%; p < 0.0001). Cardiac death and TLR were each observed in one patient, and TV-MI in two patients treated with SYNERGY 48 mm stent. Between the 1-2-year timeframe, TV-MI occurred in one additional patient. None of the patients experienced a definite or probable stent thrombosis through 2 years. CONCLUSIONS: PCI of long coronary lesions with the 48 mm SYNERGY stent demonstrated good procedural and clinical outcomes through 2 years, supporting its clinical safety and efficacy.


Assuntos
Fármacos Cardiovasculares , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo , Stents , Resultado do Tratamento
8.
Am Heart J ; 241: 101-107, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34314727

RESUMO

BACKGROUND: Drug-coated balloon (DCB) technology was developed as an alternative treatment for obstructive coronary artery disease (CAD) and in-stent restenosis (ISR). Management of coronary ISR is clinically challenging and frequently encountered in practice. The Agent DCB uses an inactive excipient to effectively deliver a targeted, therapeutic dose of paclitaxel to the vessel wall. STUDY DESIGN: AGENT IDE is a prospective, multicenter, randomized controlled trial to evaluate superiority of the Agent DCB to balloon angioplasty in treating patients with ISR. A total of 480 patients with ISR of a previously treated lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm will be initially randomized. Subjects presenting with recent myocardial infarction (MI), complex lesions, or thrombus in the target vessel will be excluded. An adaptive group sequential design with one formal interim analysis for sample size re-estimation will be conducted, and the sample size may be increased to a maximum of 600 subjects. The primary endpoint is the rate of 12-month target lesion failure (TLF; composite of any ischemia-driven revascularization of the target lesion (TLR), target vessel related MI, or cardiac death) and will be tested for superiority in the test arm against the control. Functional status and general health-related quality of life will be measured by changes in the EQ-5D scores. Subjects will be followed for 5 years following the index procedure. CONCLUSION: This study will prospectively evaluate the safety and efficacy of Agent DCB in patients treated for coronary ISR.


Assuntos
Angioplastia Coronária com Balão , Cateteres Cardíacos/classificação , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Paclitaxel/farmacologia , Reoperação , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Antineoplásicos Fitogênicos/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/cirurgia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Reoperação/efeitos adversos , Reoperação/instrumentação , Reoperação/métodos
10.
Gynecol Oncol ; 158(1): 188-193, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32456991

RESUMO

The purpose of this paper is to review the surgical care related to training in gynecologic oncology, from past, present and future perspectives. A marked decline in the incidence of cervical cancer as well as improvements in radiation therapy have led to a reduction in the numbers of radical hysterectomies and exenterations being performed. Utilization of neoadjuvant chemotherapy is reducing the extent of cytoreductive operations, including intestinal surgery. The incorporation of sentinel lymphatic mapping has reduced the number of pelvic, paraaortic and inguinal lymphadenectomies being performed. Coupled with these changes are other factors limiting time for surgical training including an explosion in targeted anticancer therapies and more individualized options beyond simple cytotoxic therapy. With what is likely to be a sustained impact on training, gynecologic oncologists will still provide a broad range of care for women with gynecologic cancer but may be quite limited in surgical scope and rely on colleagues from other surgical disciplines. Enhancement of surgical training by off-service rotations, simulation, attending advanced surgical training courses and/or a longer duration of training are currently incorporated into some programs. Programs must ensure that fellows take full advantage of the clinical materials available, particularly those related to the potential deficiencies described. Changing required research training to an additional elective year could also be considered. Based on the perspectives noted, we believe it is time for our subspecialty to reevaluate its scope of surgical training and practice.


Assuntos
Neoplasias dos Genitais Femininos/cirurgia , Procedimentos Cirúrgicos em Ginecologia/educação , Feminino , Procedimentos Cirúrgicos em Ginecologia/história , Procedimentos Cirúrgicos em Ginecologia/métodos , História do Século XIX , História do Século XX , História do Século XXI , Humanos
11.
Clin Med (Lond) ; 20(2): 212-214, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32188661

RESUMO

We report a case of a 72-year-old woman who presented with ST-elevation myocardial infarction (STEMI). However, coronary angiography showed unobstructed arteries while echocardiography (ECHO) showed severe left ventricular (LV) apical hypokinesia with ejection fraction (EF) of 25-30%. Seven months later she presented with a transient ischaemic attack and a repeat ECHO showed a normal EF.A few months later, she was diagnosed with breast cancer and as part of staging procedure, an incidental left adrenal mass was identified. This was biochemically confirmed as phaeochromocytoma (PY) and she underwent laparoscopic adrenalectomy.PY is a rare catecholamine secreting tumour arising from adrenomedullary chromaffin cells. Excessive catecholamine-induced stimulation can present as transient, reversible cardiomyopathy similar to Takotsubo cardiomyopathy and cerebrovascular events. The diagnosis of PY is often delayed but it is important to recognize PY as a cause of reversible cardiomyopathy. Early intervention is essential to improve mortality from cardiovascular and cerebrovascular complications.


Assuntos
Neoplasias das Glândulas Suprarrenais , Feocromocitoma , Cardiomiopatia de Takotsubo , Neoplasias das Glândulas Suprarrenais/complicações , Neoplasias das Glândulas Suprarrenais/diagnóstico , Idoso , Angiografia Coronária , Feminino , Ventrículos do Coração , Humanos , Feocromocitoma/complicações , Feocromocitoma/diagnóstico , Cardiomiopatia de Takotsubo/diagnóstico
12.
Circ Cardiovasc Interv ; 12(9): e008152, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31451014

RESUMO

BACKGROUND: The thin-strut SYNERGY stent has an abluminal everolimus-eluting bioabsorbable polymer coating designed to facilitate vascular healing and reduce risk of stent thrombosis. In the multicenter, randomized EVOLVE II trial (The EVOLVE II Clinical Trial to Assess the SYNERGY Stent System for the Treatment of Atherosclerotic Lesion[s]), SYNERGY was noninferior to the durable polymer PROMUS Element Plus everolimus-eluting stent for the primary end point of 1-year target lesion failure. Longer-term clinical follow-up will support the relative efficacy and safety of SYNERGY. METHODS: Patients with ≤3 native coronary lesions (reference vessel diameter ≥2.25-≤4.00 mm; length ≤34 mm) in ≤2 major epicardial vessels were randomized 1:1 to SYNERGY (N=838) or PROMUS Element Plus (N=846). EVOLVE II included a Diabetes substudy which pooled patients with diabetes mellitus from the randomized controlled trial (n=263) and from a sequential, single-arm substudy (N=203). RESULTS: The 5-year target lesion failure rate was 14.3% for SYNERGY and 14.2% for PROMUS Element Plus (P=0.91). Landmark analysis demonstrated similar rates of target lesion failure from discharge to 1-year (P=0.90) and from 1 to 5 years (P=0.94). Definite/probable stent thrombosis was infrequent in both arms (SYNERGY 0.7% versus PROMUS Element Plus 0.9%; P=0.75). There were no significant differences in the rates of cardiac death, myocardial infarction, or revascularization. Among patients with diabetes mellitus, the target lesion failure rate to 1-year was noninferior to a prespecified performance goal and to 5 years was 17.0%. CONCLUSIONS: SYNERGY demonstrated comparable outcomes to PROMUS Element Plus, with low rates of stent thrombosis and adverse events through 5 years of follow-up. Five-year clinical outcomes were favorable in patients with diabetes mellitus. These data support the long-term safety and effectiveness of SYNERGY in a broad range of patients. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01665053.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
Circ Cardiovasc Interv ; 12(4): e006918, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30998393

RESUMO

Background The impact of race/ethnicity on coronary stent outcomes in women is unknown. We compared baseline characteristics, social determinants of health, and 1-year outcomes in female African Americans (AA) and Hispanic/Latinas (HL) versus white women after coronary everolimus-eluting stent implantation in all-comer patients. Methods and Results We pooled 1863 women from the PLATINUM Diversity (n=1057 women) and PROMUS ELEMENT PLUS (n=806 women) postapproval studies, with some overlap in study sites. Social determinants of health data were only available for PLATINUM Diversity. The primary end point was 1-year major adverse cardiac events (death, myocardial infarction, or target vessel revascularization). Outcomes were risk adjusted using multivariate Cox regression. The study sample comprised 1417 white (76.1%, reference group), 296 AA (15.9%), and 107 HL (5.7%) women. AA were older, and both AA and HL had more diabetes mellitus and hypertension than white women. AA had larger reference vessel diameters but less lesion calcification, whereas HL had less lesion tortuosity but more calcification. Compared with white women, there was a trend toward higher unadjusted 1-year major adverse cardiac events in AA (12.0% versus 8.0%; P=0.06) but similar rates in HL (11.0% versus 8.0%; P=0.32), and after risk adjustment, there were no differences (AA women: hazard ratio, 1.47; 95% CI, 1.00-2.17; HL women: hazard ratio, 1.33; 95% CI, 0.71-2.44). AA had a 3-fold higher adjusted risk of 1-year myocardial infarction (hazard ratio, 3.45; 95% CI, 1.72-7.14; P=0.01) and increased risk of target vessel revascularization (hazard ratio, 1.82; 95% CI, 1.10-2.94; P=0.02). Independent predictors of major adverse cardiac events included renal disease, prior myocardial infarction, silent ischemia, history of stroke, and multivessel disease. Conclusions Race and ethnicity confer heterogeneity in women undergoing everolimus-eluting stent implantation. Despite more comorbidities and less favorable social determinants of health, AA and HL women have similar 1-year major adverse cardiac events to white women, although AA women seem to have a higher risk of 1-year myocardial infarction. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02240810.


Assuntos
Negro ou Afro-Americano , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/etnologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Disparidades nos Níveis de Saúde , Hispânico ou Latino , Intervenção Coronária Percutânea/instrumentação , Determinantes Sociais da Saúde/etnologia , População Branca , Idoso , Fármacos Cardiovasculares/efeitos adversos , Comorbidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Everolimo/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
14.
Am J Cardiol ; 123(11): 1765-1771, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30926144

RESUMO

PROMUS Element (PE) Plus post-approval study was a large prospective, observational, all-comers study designed to evaluate the safety and performance of a thin-strut platinum chromium everolimus-eluting PE Plus stent in everyday clinical practice. A total of 2,683 "real-world" patients with limited clinical or anatomic exclusion criteria were enrolled at 52 clinical sites in the United States. The study met its primary end point of 12-month cardiac death or myocardial infarction (CD/MI) compared with a prespecified performance goal (p <0.0001). Five-year clinical outcomes were evaluated in overall PE Plus post-approval study patients and high-risk subgroups. During the 5-year follow-up period, CD/MI and stent thrombosis related to the PE Plus stent occurred in 9% and 2.2% overall patients, respectively. The reported all-cause mortality rate was 15%, with 7% classified as cardiac-related. A total of 18% patients underwent target vessel revascularization, and 11% were reported as target lesion revascularization. The rates of PE Plus stent-related CD/MI remained low in patients with medically treated diabetes (13%), small vessels (9%), and long stents (10%). PE Plus stent-related thrombosis through 5 years in patients with diabetes, small vessels and long stents was 4.2%, 2.2%, and 2.6%, respectively. The occurrence of target lesion revascularization was numerically higher in patients with diabetes (16%) and long lesions (18%) than the small vessels subgroup (11%). In conclusion, the final 5-year results establish the long-term safety and efficacy of the PE Plus stent in a broad, unselected patient population representative of "real-world" clinical practice.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Cromo , Terapia Combinada , Feminino , Humanos , Masculino , Platina , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
Catheter Cardiovasc Interv ; 94(1): 82-90, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30666784

RESUMO

OBJECTIVE: We evaluated 1-year outcomes after platinum chromium everolimus-eluting stents (PtCr-EES) in small versus non-small coronary arteries within a large, diverse sample of men, women, and minorities. BACKGROUND: There exists limited outcomes data on the use of second-generation drug-eluting stent to treat small diameter coronary arteries. METHODS: We pooled patients from the PLATINUM Diversity and PROMUS Element Plus stent registries. Small-vessel percutaneous coronary intervention (SV-PCI) was defined as ≥1 target lesion with reference vessel diameter (RVD) ≤2.5 mm. Endpoints included major adverse cardiac event (MACE; death, myocardial infarction [MI] or target vessel revascularization [TVR]), target vessel failure (TVF; death related to the target vessel, target vessel MI or TVR) and definite/probable stent thrombosis (ST). Multivariable Cox regression was used to risk-adjust outcomes. RESULTS: We included 4,155/4,182 (99%) patients with available RVD, of which 1,607 (39%) underwent small-vessel PCI. SV-PCI was not associated with increased MACE (adjHR 1.02; 95%CI 0.81-1.30) or TVF (adjHR 1.07; 95%CI 0.82-1.39). MI risk was lower in white men compared to women and minorities, both in the setting of SV-PCI (adjHR 0.41; 95%CI 0.23-0.74 and adjHR 0.39; 95%CI 0.20-0.75, respectively) and for non-SV-PCI (adjHR 0.61; 95%CI 0.38-0.99 and adjHR 0.45; 95%CI 0.27-0.74, respectively). There was no significant interaction between RVD and sex or minority status for any endpoint. CONCLUSION: In a large diverse contemporary PCI outcomes database, SV-PCI with PtCr-EES was not associated with increased MACE or TVR and did not account for the increased MI risk noted in women and minorities compared to white men.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Disparidades nos Níveis de Saúde , Saúde das Minorias , Intervenção Coronária Percutânea/instrumentação , Platina , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etnologia , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etnologia , Trombose Coronária/mortalidade , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etnologia , Infarto do Miocárdio/mortalidade , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores Raciais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
16.
Catheter Cardiovasc Interv ; 94(3): 334-341, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30597737

RESUMO

BACKGROUND: The ION Study assessed clinical outcomes for the thin-strut, ION™ (TAXUS Element) Paclitaxel-Eluting Platinum Chromium Coronary Stent System (Boston Scientific, Marlborough, MA) in unselected patients. METHODS: This prospective, open-label registry enrolled the first 1,120 consenting patients treated with the ION stent without clinical or angiographic inclusion criteria at 40 clinical sites. Follow-up was at discharge, 30 days, 180 days, 1 and 2 years. The primary endpoint, the 1-year rate of cardiac death or MI (CD/MI) in PERSEUS-like patients (i.e., patients similar to those enrolled in PERSEUS, the pivotal approval trial), was tested in patients pooled from the ION study (N = 316), the European TAXUS Element post-approval registry (TE-PROVE; N = 306 PERSEUS-like patients), and the PERSEUS WH/SV populations (N = 1,166); and then compared with a prespecified performance goal. Additional outcomes were examined in the overall ION patient population. RESULTS: A total of 1,111 (out of 1,120) enrolled patients received a study stent. Most patients were male (70%) and mean age was 64 years. At 1 year, the primary endpoint of CD/MI occurred in 2.1% (6/292) of PERSEUS-like patients in ION, and 2.3% (40/1,729) of patients in the combined analysis. The upper one-sided 95% confidence interval for the combined analysis was 2.9%, which was significantly less than the performance goal of 7.6% (P < 0.001). Within patients enrolled in the ION study (N = 1,111), the rate of CD/MI was 4.5% at 1 year and 7.5% at 2 years. Definite/probable stent thrombosis occurred in 2.1% of patients at 1 year and 2.5% at 2 years. CONCLUSIONS: The results of the ION Study confirm the mid-term safety and effectiveness of the ION stent for the treatment of coronary artery disease in everyday clinical practice.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Platina , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
17.
JAMA Cardiol ; 2(12): 1303-1313, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29049508

RESUMO

Importance: There exist limited outcomes data for women and minorities after contemporary percutaneous coronary intervention (PCI). Objective: To examine 1-year outcomes in women and minorities vs white men after PCI with everolimus-eluting stents. Design, Settings, and Participants: The PLATINUM Diversity study was a single-arm study enrolling women and minorities. Patient-level pooling with the PROMUS Element Plus Post-Approval Study was prespecified. Data on social determinants of health and language were collected in the PLATINUM Diversity cohort, which included 1501 patients at 52 US sites. The PROMUS Element Plus Post-Approval study enrolled 2681 patients at 52 US sites with some site overlap and included an "all-comers" population. All patients were enrolled beginning in October 2014 and were followed for 12 months. Analyses began in August 2016. Interventions: Patients received 1 or more everolimus-eluting stent implantation. Main Outcomes and Measures: The primary end point was 1-year major adverse cardiac events (MACE), which included death/myocardial infarction (MI)/target vessel revascularization. Secondary ischemic end points were also evaluated. Results: The pooled study consisted of 4182 patients: 1635 white men (39.1%), 1863 women (white and minority) (44.5%), and 1059 minority patients (women and men) (25.3%). Women and minorities had a higher prevalence of diabetes, prior stroke, hypertension, renal disease, and congestive heart failure than white men but lower rates of multivessel disease, prior coronary artery bypass graft surgery, prior MI, and smoking. Unadjusted 1-year MACE rates (white men, 7.6%; women, 8.6%; minorities, 9.6%) were similar between groups with no significant differences after risk adjustment. The adjusted risk of death/MI was higher among women (odds ratio, 1.6; 95% CI, 1.1-2.4) and minorities (odds ratio, 1.9; 95% CI, 1.2-2.8) compared with white men and the adjusted risk of MI was higher in minorities (odds ratio, 2.6; 95% CI, 1.4-4.8). These differences were driven primarily by nonstent-related MIs. Within the PLATINUM Diversity cohort, the independent predictors of MACE were cardiogenic shock, renal disease, history of peripheral vascular disease, multivessel disease, widowhood, and lack of private insurance. Conclusions and Relevance: After contemporary everolimus-eluting stent implantation, women and minorities experience a similar risk of 1-year MACE but a higher adjusted risk of recurrent ischemic events primarily because of nonstent-related MIs. Both clinical and angiographic factors and social determinants of health, including widowhood and insurance status, contribute to 1-year MACE among women and minorities.


Assuntos
Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Etnicidade , Grupos Minoritários , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Intervenção Coronária Percutânea , Negro ou Afro-Americano/estatística & dados numéricos , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Everolimo/administração & dosagem , Feminino , Hispânico ou Latino/estatística & dados numéricos , Humanos , Imunossupressores/administração & dosagem , Indígenas Norte-Americanos/estatística & dados numéricos , Seguro Saúde , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Prospectivos , Fatores Sexuais , Determinantes Sociais da Saúde , Resultado do Tratamento , Estados Unidos/epidemiologia , Viuvez
18.
Neuromodulation ; 20(6): 582-588, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28370724

RESUMO

OBJECTIVE: Concordant paresthesia coverage is an independent predictor of pain relief following spinal cord stimulation (SCS). Using aggregate data, our objective is to produce a map of paresthesia coverage as a function of electrode location in SCS. METHODS: This retrospective analysis used x-rays, SCS programming data, and paresthesia coverage maps from the EMPOWER registry of SCS implants for chronic neuropathic pain. Spinal level of dorsal column stimulation was determined by x-ray adjudication and active cathodes in patient programs. Likelihood of paresthesia coverage was determined as a function of stimulating electrode location. Segments of paresthesia coverage were grouped anatomically. Fisher's exact test was used to identify significant differences in likelihood of paresthesia coverage as a function of spinal stimulation level. RESULTS: In the 178 patients analyzed, the most prevalent areas of paresthesia coverage were buttocks, anterior and posterior thigh (each 98%), and low back (94%). Unwanted paresthesia at the ribs occurred in 8% of patients. There were significant differences in the likelihood of achieving paresthesia, with higher thoracic levels (T5, T6, and T7) more likely to achieve low back coverage but also more likely to introduce paresthesia felt at the ribs. Higher levels in the thoracic spine were associated with greater coverage of the buttocks, back, and thigh, and with lesser coverage of the leg and foot. CONCLUSION: This paresthesia atlas uses real-world, aggregate data to determine likelihood of paresthesia coverage as a function of stimulating electrode location. It represents an application of "big data" techniques, and a step toward achieving personalized SCS therapy tailored to the individual's chronic pain.


Assuntos
Atlas como Assunto , Eletrodos Implantados , Parestesia/terapia , Estimulação da Medula Espinal/instrumentação , Estimulação da Medula Espinal/métodos , Adulto , Idoso , Eletrodos Implantados/normas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Parestesia/diagnóstico , Sistema de Registros , Estudos Retrospectivos , Estimulação da Medula Espinal/normas
19.
Catheter Cardiovasc Interv ; 86(6): 994-1001, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25678402

RESUMO

BACKGROUND: The TAXUS Element (ION) platinum chromium paclitaxel-eluting stent (PtCr-PES) incorporates a thin (81 µm) strut design with a similar polymer and drug dose density as prior PES. The pivotal PERSEUS trial program consisted of two studies: PERSEUS Workhorse (WH) and PERSEUS Small Vessel (SV). The PERSEUS WH trial demonstrated the PtCr-PES to be non-inferior to the predicate TAXUS Express PES (TE-PES) for target lesion failure (TLF) at 1 year and in-segment angiographic percent diameter stenosis at 9 months. The PERSEUS SV trial demonstrated the PtCr-PES to be superior to a historical bare metal stent (BMS) for angiographic late lumen loss at 9 months. Long-term (5-year) clinical outcomes following PtCr-PES have not been previously reported. METHODS: PERSEUS WH was a prospective, Bayesian, 3:1 randomized (PtCr-PES vs. TE-PES) trial in patients with lesion length ≤28 mm and vessel diameter ≥2.75 to ≤4.0 mm. PERSEUS SV was a prospective, single-arm trial in patients with lesion length ≤20 mm and vessel diameter ≥2.25 to <2.75 mm comparing PtCr-PES to a matched historical BMS control. RESULTS: Among randomized subjects in the PERSEUS WH study, clinical event rates at 5 years were similar between treatment groups, including TLF (12.9% TE-PES vs. 12.1% PtCr-PES; P = 0.66). In the PERSEUS SV study, 5-year rates of MACE, and TLF were significantly lower for PtCr-PES (vs. BMS) following adjustment for baseline characteristics and were primarily due to lower target lesion revascularization rates (27.2% BMS vs. 14.9% PtCr-PES; P = 0.049). CONCLUSIONS: At 5 years, the PtCr-PES provides efficacy and safety that is comparable to the TE-PES and superior efficacy with similar safety when compared with BMS in smaller caliber vessels. Cumulative stent thrombosis rates remained low and similar through 5 years for both DES platforms.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença das Coronárias/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Desenho de Prótese/métodos , Adulto , Idoso , Angioplastia Coronária com Balão/mortalidade , Teorema de Bayes , Cromo/química , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Platina/química , Estudos Prospectivos , Falha de Prótese , Medição de Risco , Índice de Gravidade de Doença , Método Simples-Cego , Estatísticas não Paramétricas , Taxa de Sobrevida , Taxus , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
20.
Cardiovasc Revasc Med ; 16(2): 65-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25576273

RESUMO

BACKGROUND/PURPOSE: Bare metal stents (BMS) have similar rates of death and myocardial infarction (MI) compared to drug-eluting stents (DES). DES lower repeat revascularization rates compared to BMS, but may have higher rates of late stent thrombosis (ST) potentially due to impaired endothelialization requiring longer dual anti-platelet therapy (DAPT). OMEGA evaluated a novel BMS designed to have improved deliverability and radiopacity, in comparison to currently available platforms. METHODS/MATERIALS: OMEGA was a prospective, multicenter, single-arm study enrolling 328 patients at 37 sites (US and Europe). Patients received the OMEGA stent (bare platinum chromium element stent) for the treatment of de novo native coronary artery lesions (≤28 mm long; diameter ≥2.25 mm to ≤4.50mm). The primary endpoint was 9-month target lesion failure (TLF: cardiac death, target vessel-related MI, target lesion revascularization [TLR]) compared to a prespecified performance goal (PG) based on prior generation BMS. All major cardiac events were independently adjudicated. DAPT was required for a minimum of 1 month post procedure. RESULTS: In the OMEGA study, the mean age was 65; 17% had diabetes mellitus. The primary endpoint was met; 9 month TLF rate was 11.5%, and the upper 1-sided 95% confidence bound of 14.79% was less than the prespecified PG of 21.2% (p<0.0001). One-year event rates were low including a TLF rate of 12.8% and an ST rate of 0.6% at 12 months. CONCLUSIONS: One-year outcomes of OMEGA show low rates of TLF, revascularization and ST. This supports safety and efficacy of the OMEGA BMS for the treatment of coronary artery disease.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/terapia , Metais/uso terapêutico , Segurança do Paciente/estatística & dados numéricos , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/mortalidade , Cromo/uso terapêutico , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Platina/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Índice de Gravidade de Doença , Método Simples-Cego , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...