Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tomography ; 9(4): 1515-1525, 2023 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624114

RESUMO

Orbital floor fractures (OFFs) are common injuries of the midface and may result in long-term complications. The aim of this study was to compare two restoration materials, PDS foils and titanium meshes, with regards to (1) clinical outcome and (2) reduction in orbital volume. The monocentric discovery cohort was analyzed retrospectively and included 476 patients with OFFs treated between 2010 and 2020. A subcohort of 104 patients (study cohort) with isolated OFFs and available high-resolution imaging material was used for volume measurements. Postoperative complications were not significantly different between patients treated with different restoration materials. Prevalence of revision surgery was significantly higher in patients treated with thick PDS foils (25 mm). OFFs treated with PDS foils and titanium meshes showed a significant reduction in orbital volume (p = 0.0422 and p = 0.0056, respectively), however, this volume decrease was significantly less pronounced in patients treated with PDS foils alone (p = 0.0134). Restoration using PDS foil in an isolated OFF reduces the orbital volume to a lesser extent than titanium mesh. Class III patients according to the classification of Jaquiéry with a missing bony ledge medial to the infraorbital fissure particularly benefit from restoration with PDS foils due to a lower reduction in the orbital volume. Regarding short- and long-term postoperative complications, a PDS foil thickness of 0.15 mm appears equivalent to titanium mesh in the treatment of OFFs.


Assuntos
Complicações Pós-Operatórias , Titânio , Humanos , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico por imagem
2.
Tomography ; 9(2): 579-588, 2023 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-36961006

RESUMO

Orbital floor fractures represent a common fracture type of the midface and are standardly diagnosed clinically as well as radiologically using linear measurement methods. The aim of this study was to evaluate the accuracy of diagnostic measurements of isolated orbital floor fractures based on two-dimensional (2D) and three-dimensional (3D) measurement techniques. A cohort of 177 patients was retrospectively and multi-centrically evaluated after surgical treatment of an orbital floor fracture between 2010 and 2020. In addition to 2D and 3D measurements of the fracture area, further fracture-related parameters were investigated. Calculated fracture areas using the 2D measurement technique revealed an average area of 287.59 mm2, whereas the 3D measurement showed fracture areas with a significantly larger average value of 374.16 mm2 (p < 0.001). On average, the 3D measurements were 1.53-fold larger compared to the 2D measurements. This was observed in 145 patients, whereas only 32 patients showed smaller values in the 3D-based approach. However, the process duration of the 3D measurement took approximately twice as long as the 2D-based procedure. Nonetheless, 3D-based measurement of orbital floor defects provides a more accurate estimation of the fracture area than the 2D-based procedure and can be helpful in determining the indication and planning the surgical procedure.


Assuntos
Fraturas Orbitárias , Humanos , Estudos Retrospectivos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Órbita/cirurgia , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...