Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 47(7): 1689-1692, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35363719

RESUMO

Optical power measurements are needed in practically all technologies based on light. Here, we report a general-purpose optical power detector based on the photoacoustic effect. Optical power incident on the detector's black absorber produces an acoustic signal, which is further converted into an electrical signal using a silicon-cantilever pressure transducer. We demonstrate an exceptionally large spectral coverage from ultraviolet to far infrared, with the possibility for further extension to the terahertz region. The linear dynamic range of the detector reaches 80 dB, ranging from a noise-equivalent power of 6 n W/H z to 600 mW (independent of signal averaging time).

2.
Photoacoustics ; 23: 100265, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34094850

RESUMO

We present an experimental comparison of photoacoustic responsivities of common highly absorbing carbon-based materials. The comparison was carried out with parameters relevant for photoacoustic power detectors and Fourier-transform infrared (FTIR) spectroscopy: we covered a broad wavelength range from the visible red to far infrared (633 nm to 25 µm) and the regime of low acoustic frequencies (< 1 kHz). The investigated materials include a candle soot-based coating, a black paint coating and two different carbon nanotube coatings. Of these, the low-cost soot absorber produced clearly the highest photoacoustic response over the entire measurement range.

3.
Opt Express ; 21(8): 10240-50, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23609733

RESUMO

Highly sensitive cantilever-enhanced photoacoustic detection of hydrogen cyanide and methane in the mid-infrared region is demonstrated. A mid-infrared continuous-wave frequency tunable optical parametric oscillator was used as a light source in the experimental setup. Noise equivalent detection limits of 190 ppt (1 s) and 65 ppt (30 s) were achieved for HCN and CH(4), respectively. The normalized noise equivalent absorption coefficient is 1.8 × 10(-9) W cm(-1) Hz(-1/2).


Assuntos
Gases/análise , Sistemas Microeletromecânicos/instrumentação , Microquímica/instrumentação , Oscilometria/instrumentação , Técnicas Fotoacústicas/instrumentação , Espectrofotometria Infravermelho/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Gases/química
4.
Appl Spectrosc ; 64(3): 293-7, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20223064

RESUMO

The sensitivity of photoacoustic spectroscopy was improved with the invention of optical cantilever detection (PAS-OCD). However, the ability of present PAS-OCD devices to carry out multicomponent detection is poor. To overcome this, a Fourier transform infrared photoacoustic spectrometer with optical cantilever detection (FT-IR-PAS-OCD) prototype was assembled. In this article, the first evaluation and performance tests of the prototype are described. Selectivity, sensitivity, and the linearity of the signal response are evaluated. The linear response was studied for methane and carbon dioxide and confirmed in the whole analyzed concentration range from 500 to 3500 ppm and from 2500 to 17500 ppm, respectively. The calculated signal-to-noise ratio (SNR) and limit of detection were 2027 and 0.5 ppm for methane and 1362 and 4 ppm for carbon dioxide, with a measurement time of 100 seconds. Selectivity was studied with a multicomponent gas mixture of propene, methane, carbon dioxide, and methylmercaptane. The results indicate that a quantitative analysis of all components in the mixture is possible using the FT-IR-PAS-OCD.

5.
Appl Spectrosc ; 62(6): 655-60, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18559153

RESUMO

A photoacoustic detector based on the optical cantilever microphone has been built. The detector is capable of measuring solid-, liquid-, and gas-phase samples. Photoacoustic Fourier transform infrared (FT-IR) measurement with three samples in different phases was demonstrated. Example samples were polyethene, sunflower oil, and methane. The sensitivity of the cell was compared to a commercial photoacoustic FT-IR detector. With the standard carbon black sample the cantilever detector gave approximately five times higher signal-to-noise ratio than the reference detector. The sensitivity with methane was also compared to the DTGS detector of the FT-IR instrument corresponding to an absorption path of 6.3 cm. Simulation of the photoacoustic signal showed that a compromise has to be made in the cell design between sensitivity for solid- and gas-phase samples but it is possible to highly enhance the sensitivity for all types of samples by reducing cantilever dimensions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...