Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Biomech ; 8(1): 75-84, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34806553

RESUMO

Electromagnetic (EM) tracking has been used to quantify biomechanical parameters of the lower limb and lumbar spine during ergometer rowing to improve performance and reduce injury. Optical motion capture (OMC) is potentially better suited to measure comprehensive whole-body dynamics in rowing. This study compared accuracy and precision of EM and OMC displacements by simultaneously recording kinematics during rowing trials at low, middle, and high rates on an instrumented ergometer (n=12). Trajectories calculated from OMC and EM sensors attached to the pelvis, lumbar spine, and right leg were highly correlated, but EM tracking lagged behind ergometer and OMC tracking by approximately 6%, yielding large RMS errors. When this phase-lag was corrected by least squares minimization, agreement between systems improved. Both systems demonstrated an ability to adequately track large dynamic compound movements in the sagittal plane but struggled at times to precisely track small displacements and narrow angular ranges in medial/lateral and superior/inferior directions. An OMC based tracking methodology can obtain equivalence with a previously validated EM system, for spine and lower limb metrics. Improvements in speed and consistency of data acquisition with OMC are beneficial for dynamic motion studies. Compatibility ensures continuity by maintaining the ability to compare to prior work.


Assuntos
Esportes , Fenômenos Biomecânicos , Fenômenos Eletromagnéticos , Ergometria , Vértebras Lombares
2.
Scand J Med Sci Sports ; 30(11): 2205-2214, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32715526

RESUMO

Heavily loaded overhead training tasks, such as pull-ups are an effective strength training and rehabilitation exercise requiring high muscle forces maintained over a large range of motion. This study used experiments and computational modeling to examine loading patterns during three different pull-up variants and highlighted risks to vulnerable musculoskeletal structures. Optical motion tracking and a force platform captured kinematics and kinetics of 11 male subjects with no history of shoulder pathology, during performance of three pull-up variants-pronated front grip, pronated wide grip, and supinated reverse grip. UK National Shoulder model (UKNSM) simulated biomechanics of the shoulder girdle. Muscle forces and activation patterns were analyzed by repeated measures ANOVA with post-hoc comparisons. Motor group recruitment was similar across all pull-up techniques, with upper limb depression occurring secondary to torso elevation. Stress-time profiles show significant differences in individual muscle patterns among the three pull-up variants, with the most marked differences between wide grip and reverse grip. Comparing across techniques, latissimus dorsi was relatively more active in wide pull-ups (P < .01); front pull-ups favored activation of biceps brachii and brachialis (P < .02); reverse pull-ups displayed higher proportional rotator cuff activation (P < .01). Pull-ups promote stability of the shoulder girdle and activation of scapula stabilizers and performing pull-ups over their full range of motion is important as different techniques and phases emphasize different muscles. Shoulder rehabilitation and strength & conditioning programs should encourage incorporation of all three pull-up variants with systematic progression to provide greater global strengthening of the torso and upper limb musculature.


Assuntos
Treinamento Resistido/métodos , Manguito Rotador/fisiologia , Extremidade Superior/fisiologia , Adulto , Braço/fisiologia , Fenômenos Biomecânicos , Simulação por Computador , Eletromiografia , Humanos , Cinética , Masculino , Força Muscular , Músculo Esquelético/fisiologia , Treinamento Resistido/efeitos adversos , Fatores de Risco , Lesões do Manguito Rotador/fisiopatologia , Escápula/fisiologia , Ombro/fisiologia , Tronco/fisiologia , Adulto Jovem
3.
Appl Bionics Biomech ; 2020: 2041549, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32676126

RESUMO

In the last few decades, a number of technological developments have advanced the spread of wearable sensors for the assessment of human motion. These sensors have been also developed to assess athletes' performance, providing useful guidelines for coaching, as well as for injury prevention. The data from these sensors provides key performance outcomes as well as more detailed kinematic, kinetic, and electromyographic data that provides insight into how the performance was obtained. From this perspective, inertial sensors, force sensors, and electromyography appear to be the most appropriate wearable sensors to use. Several studies were conducted to verify the feasibility of using wearable sensors for sport applications by using both commercially available and customized sensors. The present study seeks to provide an overview of sport biomechanics applications found from recent literature using wearable sensors, highlighting some information related to the used sensors and analysis methods. From the literature review results, it appears that inertial sensors are the most widespread sensors for assessing athletes' performance; however, there still exist applications for force sensors and electromyography in this context. The main sport assessed in the studies was running, even though the range of sports examined was quite high. The provided overview can be useful for researchers, athletes, and coaches to understand the technologies currently available for sport performance assessment.

4.
Ultrasound Med Biol ; 41(3): 713-23, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25683220

RESUMO

Realistic computer simulation of closed head trauma requires accurate mechanical properties of brain tissue, ideally in vivo. A substantive deficiency of most existing experimental brain data is that properties were identified through in vitro mechanical testing. This study develops a novel application of shear wave elasticity imaging to assess porcine brain tissue shear modulus in vivo. Shear wave elasticity imaging is a quantitative ultrasound technique that has been used here to examine changes in brain tissue shear modulus as a function of several experimental and physiologic parameters. Animal studies were performed using two different ultrasound transducers to explore the differences in physical response between closed skull and open skull arrangements. In vivo intracranial pressure in four animals was varied over a relevant physiologic range (2-40 mmHg) and was correlated with shear wave speed and stiffness estimates in brain tissue. We found that stiffness does not vary with modulation of intracranial pressure. Additional in vitro porcine specimens (n = 14) were used to investigate variation in brain tissue stiffness with temperature, confinement, spatial location and transducer orientation. We observed a statistically significant decrease in stiffness with increased temperature (23%) and an increase in stiffness with decreasing external confinement (22-37%). This study determined the feasibility of using shear wave elasticity imaging to characterize porcine brain tissue both in vitro and in vivo. Our results underline the importance of temperature- and skull-derived boundary conditions to brain stiffness and suggest that physiologic ranges of intracranial pressure do not significantly affect in situ brain tissue properties. Shear wave elasticity imaging allowed for brain material properties to be experimentally characterized in a physiologic setting and provides a stronger basis for assessing brain injury in computational models.


Assuntos
Encéfalo/fisiologia , Ecoencefalografia/métodos , Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Animais , Técnicas In Vitro , Pressão Intracraniana , Suínos , Transdutores
5.
Ann Biomed Eng ; 39(4): 1306-12, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21107696

RESUMO

The hydraulic resistance R across osteochondral tissue, especially articular cartilage, decreases with degeneration and erosion. Clinically useful measures to quantify and diagnose the extent of cartilage degeneration and efficacy of repair strategies, especially with regard to pressure maintenance, are still developing. The hypothesis of this study was that hydraulic resistance provides a quantitative measure of osteochondral tissue that could be used to evaluate the state of cartilage damage and repair. The aims were to (1) develop a device to measure R in an arthroscopic setting, (2) determine whether the device could detect differences in R for cartilage, an osteochondral defect, and cartilage treated using a hydrogel ex vivo, and (3) determine how quickly such differences could be discerned. The apparent hydraulic resistance of defect samples was ~35% less than intact cartilage controls, while the resistance of hydrogel-filled groups was not statistically different than controls, suggesting some restoration of fluid pressurization in the defect region by the hydrogel. Differences in hydraulic resistance between control and defect groups were apparent after 4 s. The results indicate that the measurement of R is feasible for rapid and quantitative functional assessment of the extent of osteochondral defects and repair. The arthroscopic compatibility of the device demonstrates the potential for this measurement to be made in a clinical setting.


Assuntos
Artroscopia/instrumentação , Cartilagem Articular/lesões , Cartilagem Articular/patologia , Animais , Fenômenos Biomecânicos , Engenharia Biomédica/instrumentação , Doenças das Cartilagens/diagnóstico , Doenças das Cartilagens/cirurgia , Cartilagem Articular/cirurgia , Bovinos , Desenho de Equipamento , Hidrogéis , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...