Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
2.
J Hand Surg Am ; 2023 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-36623944

RESUMO

PURPOSE: This study aimed to determine the results of radiolunate arthrodesis for rheumatoid arthritis (RA) after a long-term follow-up period of up to 20 years under tight postoperative medical control of RA. We also compared the results between patients with and without degenerative changes in the midcarpal joints at follow-up. We determined the radiologic factors predictive of secondary degenerative changes in the midcarpal joint. METHODS: This was a long-term retrospective analysis of 16 wrists of 14 patients with RA treated with radiolunate arthrodesis first reported in 2013. The mean follow-up period was 14 years (range, 8-23 years; SD, 4.6 years). Ten wrists had a Larsen classification of grade III, whereas 6 wrists had grade IV. The range of motion was assessed, and clinical outcomes were graded using the Mayo Wrist Score and Stanley classification system. The Carpal Height Index, Ulnar Translation Index, and changes in the midcarpal joint contour were determined from radiographs. We categorized the changes in the midcarpal joint as unchanged or degenerative. RESULTS: At final follow-up, the clinical scores improved; however, the extension and flexion range of motion was significantly reduced compared with that before surgery. The Carpal Height Index and Ulnar Translation Index improved immediately after surgery and remained stable at final follow-up. The changes in the midcarpal joint were categorized as unchanged in 6 wrists and degenerative in 10 wrists. The clinical outcomes were similar between the groups. The mean preoperative Ulnar Translation Index was significantly higher in the degenerative group than in the unchanged group. CONCLUSIONS: Radiolunate arthrodesis in patients with RA maintained good clinical results and corrected alignment, even during long-term follow-up. Preoperative severe ulnar translation deformity was a risk factor for postoperative degeneration of the midcarpal joint, and pre-existing degenerative changes at the midcarpal joint might lead to loss of wrist range of motion. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

3.
J Orthop Sci ; 28(1): 131-137, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34838411

RESUMO

BACKGROUND: Anatomical total shoulder arthroplasty (TSA) provides successful long-term outcomes but complications can occur after 10 years that require revision. Computed tomography (CT) is a useful tool for assessing radiolucent lines around the glenoid component of TSA; however, the merits of long-term post-TSA follow up with CT are unclear. The purpose of this study was to evaluate the long-term outcomes after TSA of Japanese population and to identify factors related to radiolucency around the glenoid component using CT. METHODS: A retrospective review was conducted of TSA patients who had completed at least 10 years of clinical follow up. Radiographs and CT images of the affected shoulder obtained at the last follow up were evaluated for radiolucent lines around the stem and each peg, superior inclination and retroversion of the glenoid component, subluxation index, and critical shoulder angle (CSA). Shoulder ROM, Constant-Murley score and UCLA score were compared between the preoperative and last follow up period. RESULTS: Eighteen shoulders in 16 patients met the inclusion criteria. Mean patient age was 61 years, mean follow up period was 137 months, and mean Yian CT score was 19%. CT score was significantly highest in pegs located inferiorly (p < 0.05). Mean glenoid superior inclination was 12.6°, retroversion was -0.3°, subluxation index was 46%, and CSA was 33.7°. Glenoid superior inclination was significantly lower (p = 0.007) in shoulders with possible loosening than in cases with no loosening (5.0° vs 15.6°). Mean Constant score and UCLA score improved significantly after TSA, from 25.8 to 10.7 points preoperatively to 70.1 and 28.9 points postoperatively, respectively. Mean shoulder flexion, internal rotation, and external rotation also showed improvement postoperatively. CONCLUSION: TSA provides good long-term outcomes. Radiolucency was present most frequently around the inferior pegs of the glenoid component. Glenoid superior inclination may affect the formation of radiolucent lines around glenoid pegs. LEVEL OF EVIDENCE: Level IV; Case Series; Treatment study.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Luxações Articulares , Articulação do Ombro , Humanos , Pessoa de Meia-Idade , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Polietileno , População do Leste Asiático , Tomografia Computadorizada por Raios X , Luxações Articulares/cirurgia , Estudos Retrospectivos , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Resultado do Tratamento , Seguimentos
5.
Sci Rep ; 12(1): 21190, 2022 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-36477208

RESUMO

Recently, three-dimensional (3D) planning, patient-specific instruments, and navigation system have been developed to improve the accuracy of baseplate placement in reverse shoulder arthroplasty (RSA). The purpose of this study was to evaluate baseplate placement using the navigation system. Sixty-four shoulders in 63 patients who underwent RSA for rotator cuff tear arthropathy or irreparable rotator cuff tears were enrolled. Conventional RSA was performed in 31 shoulders and navigated RSA using pre-operative planning software was performed in 33 shoulders. The use of augmented baseplates, the version and inclination of the baseplate, and screw length were compared between conventional RSA and navigated RSA. Augmented baseplates were used more frequently in navigated RSA than in conventional RSA (20 vs 9 shoulders, p = 0.014). Baseplate alignment was 1.0° (SD 5.1) of retroversion and 2.4° (SD 6.8) of superior inclination in conventional RSA and 0.2° (SD 1.9) of anteversion and 0.3° (SD 1.7) of superior inclination in navigated RSA. Compared with conventional RSA, precision of baseplate version and inclination were higher in navigated RSA (both p < 0.001). Superior, inferior, and posteroinferior screws were significantly longer in navigated RSA than in conventional RSA (p = 0.021, 0.001 and < 0.001, respectively). Precision of superior and inferior screw lengths was significantly higher in navigated RSA than in conventional RSA (both p = 0.001). Our results suggest that adoption of pre-operative planning software increased augmented baseplate use to minimize the glenoid reaming. The navigation system allows placement of the baseplate accurately, according to the pre-operative plan. Furthermore, the navigation system enables monitoring of screw length and direction in real time.


Assuntos
Artroplastia do Ombro , Humanos
6.
BMC Musculoskelet Disord ; 23(1): 821, 2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36042450

RESUMO

BACKGROUND: Although total wrist arthroplasty (TWA) has become a common treatment option for wrists with damage due to rheumatoid arthritis (RA), the optimal implant axial alignment for TWA has been inadequately studied. This study was performed to investigate the relationships between implant alignment and carpal rotational alignment and the wrist range of motion (ROM) following TWA. METHODS: This study included 18 patients who underwent TWA using a DARTS® Total Wrist System (Teijin Nakashima Medical, Okayama, Japan) for wrist RA. Pre- and 6-month postoperative computed tomography scans were performed, including the radial volar line (Rv), capitohamate axis (CH), and Rv-CH angle in axial scans. The wrist ROM was also measured. The relationship between the Rv-CH angle and ROM was examined. RESULTS: The mean Rv-CH angle showed significant wrist pronation from 73.0° to 83.4° postoperatively. We observed a significant positive correlation (0.58) between the postoperative Rv-CH angle and extension and a significant negative correlation (- 0.56) between the postoperative Rv-CH angle and flexion. CONCLUSIONS: Implantation of the DARTS® TWA prosthesis resulted in pronation of the carpal axial alignment, which was correlated with postoperative wrist extension. The volar cortex of the distal radius can be a novel reference axis for adequate implant placement.


Assuntos
Artrite Reumatoide , Artroplastia de Substituição , Ossos do Carpo , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/cirurgia , Artroplastia de Substituição/efeitos adversos , Humanos , Amplitude de Movimento Articular , Punho/cirurgia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia
7.
Case Rep Orthop ; 2022: 2162331, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35496949

RESUMO

Introduction: Simultaneous bilateral fractures of the proximal humerus are infrequent, and simultaneous bilateral three- or four-part fractures are even rarer. Reverse shoulder arthroplasty (RSA) is being used increasingly for the treatment of three- and four-part fractures of the proximal humerus. However, treatment of simultaneous bilateral fractures of the proximal humerus is difficult because of concern about postoperative immobilization and rehabilitation. Case Presentation. A 75-year-old woman presented with bilateral shoulder pain subsequent to a fall on the street. Physical examination and radiographs showed simultaneous bilateral fractures of the proximal humerus. The right side fracture was classified as a four-part fracture and the left side fracture as a three-part fracture, according to Neer's classification. The right shoulder had a risk of avascular necrosis of the humeral head. For the left shoulder, the fracture type had caused ischemia of the humeral head. Single-stage bilateral RSA was performed 9 days after the injury. An abduction pillow was applied for 5 weeks postoperatively. Passive motion exercises were permitted starting at 4 weeks postoperatively, and active range of motion exercises were permitted at 6 weeks postoperatively. At the patient's most recent follow-up 30 months after surgery, the patient reported no restriction of the activities of daily living. Radiographs revealed no lucent line on the humerus and glenoid components, although bone resorption and superior retraction of the tuberosities on both sides were observed. Conclusions: Single-stage bilateral RSA improved shoulder function, but healing of the greater tuberosity can affect the improvement in external rotation after the operation. Although a long-term follow-up is needed, single-stage bilateral RSA appears to be a viable treatment option.

8.
Front Neurol ; 13: 832569, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35432160

RESUMO

Recent studies suggest that blood flow changes in the median nerve may help confirm a diagnosis of carpal tunnel syndrome (CTS). Herein, we examined the utility of superb microvascular imaging (SMI), a new ultrasonographic (US) technique for visualizing microvascular flow, for detecting blood flow differences between CTS patients and healthy controls. We performed a retrospective analysis of 28 hands with suspected CTS. Patients received both nerve conduction and US examinations. Ten healthy volunteers were enrolled as the control group. The nerve compression ratio and the blood flow signal area were quantified using color Doppler US (CDUS), power Doppler US (PDUS), and SMI. Correlation analyses between the blood flow signal area, the compound muscle action potential of the thenar muscle, and the nerve compression ratio were performed. As a result, the mean nerve compression ratio was found to be significantly higher in the CTS group. There were no differences in the blood flow signal area between the groups using CDUS, while PDUS and SMI showed higher blood flow signals in the CTS group. The blood flow signal area measured by SMI had stronger correlations with the compound muscle action potential amplitude and the nerve compression ratio than those for PDUS. The diagnostic utility of SMI was equivalent to PDUS, but superior to conventional CDUS. Nevertheless, the blood flow signal by SMI was more strongly correlated with the electrophysiological severity and compression ratio than for PDUS. Use of SMI in future studies may help clarify the underlying mechanisms of blood flow changes in CTS.

11.
Ann Jt ; 7: 20, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38529150

RESUMO

Osteoid osteomas are benign, typically intracortical lesions most often affecting the diaphysis of long bones. Nocturnal pain and characteristic symptoms that are relieved by administration of non-steroidal anti-inflammatory drugs (NSAIDs) are present and can help in the diagnosis of osteoid osteoma. We report a case of 18-year-old boy with an osteoid osteoma in the olecranon fossa with an atypical clinical manifestation. The initial manifestation was arthritis-like symptoms such as local heat, motion pain rather than pain at rest, and limited range-of-motion. Notably, NSAIDs were not effective at all for relieving his symptoms. Magnetic resonance imaging showed bone marrow edema around the elbow joint. The symptoms were resistant to conservative treatments, and thus, surgical resection was required. Histopathological examination showed that the lesion consisted of woven bones and osteoid tissues that anastomosed with each other. Combined with a tumor size that was less than 2 cm, clinicopathologically, the tumor was diagnosed as an osteoid osteoma. The pain was immediately relieved after the operation, and range-of-motion recovered at 2 months postoperatively. At 1 year after the surgery, the patient did not exhibit recurrence of the tumor or exacerbation of elbow pain and had a full range of elbow motion. Osteoid osteoma should be considered for the differential diagnosis of arthritis of the elbow in patients who are adolescents and young adults, which is the peak age of onset for osteoid osteoma.

12.
Sci Rep ; 11(1): 17891, 2021 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-34504202

RESUMO

Ulnar shortening osteotomy (USO) for ulnar impaction syndrome potentially leads to degenerative changes of the distal radioulnar joint (DRUJ). This study was performed to evaluate the effect of the sigmoid notch morphology on the stress distribution pattern of the DRUJ using computed tomography (CT) osteoabsorptiometry (CT-OAM). We reviewed the pre- and postoperative transverse CT images of 15 wrists that had undergone USO. The examined wrists were classified into two groups based on the sigmoid notch morphology: the linear-type notch (type L) and the curved-type notch (type C). We calculated and statistically compared the percentage of the high-density area (%HDA) in each divided region of the sigmoid notch. In type L, %HDA was significantly larger in the distal-dorsal region of the sigmoid notch before USO. Postoperatively, in type L, no specific regions showed a significantly different %HDA. In type C, %HDA was significantly larger in the distal-volar region of the sigmoid notch before USO. Postoperatively, %HDA of type C was significantly larger in the proximal-volar region. Our results suggest that in patients with ulnar impaction syndrome, morphological evaluation of the sigmoid notch can serve as a predictor of osteoarthritis in the DRUJ with or without USO.


Assuntos
Osteoartrite/cirurgia , Osteotomia , Ulna/cirurgia , Articulação do Punho/fisiopatologia , Articulação do Punho/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Osteotomia/efeitos adversos , Osteotomia/métodos , Lesões do Manguito Rotador/fisiopatologia , Lesões do Manguito Rotador/cirurgia , Tomografia Computadorizada por Raios X/métodos , Ulna/fisiopatologia
13.
Orthop J Sports Med ; 9(3): 2325967121989676, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34250159

RESUMO

BACKGROUND: One of the most important limitations of osteochondral autograft transplant is the adverse effect on donor sites in the knee. Ultrapurified alginate (UPAL) gel is a novel biomaterial that enhances hyaline-like cartilage repair for articular defects. To avoid the need for knee cartilage autografting when treating osteochondritis dissecans (OCD) of the capitellum, we developed a surgical procedure involving a bone marrow stimulation technique (BMST) augmented by implantation of UPAL gel. HYPOTHESIS: BMST augmented by UPAL gel implantation improves the cartilage repair capacity and provides satisfactory clinical outcomes in OCD of the capitellum. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 5 athletes with advanced capitellar OCD in the dominant elbow underwent BMST augmented by implantation of UPAL gel. The osteochondral defects were filled with UPAL gel after BMST. At a mean follow-up of 97 weeks, all patients were evaluated clinically and radiographically. RESULTS: At final follow-up, all 5 patients had returned to competitive-level sports, and 4 patients were free from elbow pain. The mean Timmerman-Andrews score significantly improved from 100 to 194 points. Radiographically, all patients exhibited graft incorporation and a normal contour of the subchondral cortex. Magnetic resonance imaging showed that the preoperative heterogeneity of the lesion had disappeared, and the signal intensity had returned to normal. Arthroscopic examinations consistently exhibited improvement in the International Cartilage Regeneration and Joint Preservation Society (ICRS) grade of lesions from 3 or 4 to 1 or 2 in 4 patients at 85 weeks postoperatively. Histologic analysis of biopsy specimens revealed an average total ICRS Visual Assessment Scale II histologic score of 1060. CONCLUSION: The acellular cartilage repair technique using UPAL gel for advanced capitellar OCD provided satisfactory clinical and radiographic results. The present results suggest that this novel technique is a useful, minimally invasive approach for treating cartilaginous lesions in athletes.

14.
Am J Sports Med ; 49(8): 2199-2210, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34061689

RESUMO

BACKGROUND: Ultrapurified alginate (UPAL) gel implantation has been demonstrated as effective in cartilage repair for osteochondral defects; however, cell transplantation within UPAL gels would be required to treat larger defects. HYPOTHESIS: The combination of UPAL gel and bone marrow aspirate concentrate (BMAC) would enhance cartilage repair and subchondral bone repair for large osteochondral defects. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 104 osteochondral defects (1 defect per knee) of 52 rabbits were randomly divided into 4 groups (26 defects per group): defects without any treatment (Defect group), defects treated using UPAL gel alone (UPAL group), defects treated using UPAL gel containing allogenic bone marrow mesenchymal stromal cells (UPAL-MSC group), and defects treated using UPAL gel containing BMAC (UPAL-BMAC group). At 4 and 16 weeks postoperatively, macroscopic and histologic evaluations and measurements of repaired subchondral bone volumes of reparative tissues were performed. Collagen orientation and mechanical properties of the reparative tissue were assessed at 16 weeks. RESULTS: The defects in the UPAL-BMAC group were repaired with hyaline-like cartilage with well-organized collagen structures. The histologic scores at 4 weeks were significantly higher in the UPAL-BMAC group (16.9 ± 2.0) than in the Defect group (4.7 ± 1.9; P < .05), the UPAL group (10.0 ± 3.3; P < .05), and the UPAL-MSC group (12.2 ± 2.9; P < .05). At 16 weeks, the score in the UPAL-BMAC group (24.4 ± 1.7) was significantly higher than those in the Defect group (9.0 ± 3.7; P < .05), the UPAL group (14.2 ± 3.9; P < .05), and the UPAL-MSC group (16.3 ± 3.6; P < .05). At 4 and 16 weeks, the macroscopic evaluations were significantly superior in the UPAL-BMAC group compared with the other groups, and the values of repaired subchondral bone volumes in the UPAL-BMAC group were significantly higher than those in the Defect and UPAL groups. The mechanical properties of the reparative tissues were significantly better in the UPAL-BMAC group than in the other groups. CONCLUSION: The implantation of UPAL gel containing BMAC-enhanced hyaline-like cartilage repair and subchondral bone repair of osteochondral defects in a rabbit knee model. CLINICAL RELEVANCE: These data support the potential clinical application of 1-step treatment for large osteochondral defects using biomaterial implantation with cell transplantation.


Assuntos
Alginatos , Cartilagem Articular , Animais , Coelhos , Alginatos/farmacologia , Medula Óssea , Regeneração Óssea , Cartilagem Articular/cirurgia , Géis , Cartilagem Hialina
16.
Am J Sports Med ; 49(6): 1505-1511, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33831318

RESUMO

BACKGROUND: Osteochondral allograft transplantation is 1 treatment option for focal articular cartilage defects of the knee. Large irregular defects, which can be treated using an oblong allograft or multiple overlapping allografts, increase the procedure's technical complexity and may provide suboptimal cartilage and subchondral surface matching between donor grafts and recipient sites. PURPOSE: To quantify and compare cartilage and subchondral surface topography mismatch and cartilage step-off for oblong and overlapping allografts using a 3-dimensional simulation model. STUDY DESIGN: Controlled laboratory study. METHODS: Human cadaveric medial femoral hemicondyles (n = 12) underwent computed tomography and were segmented into cartilage and bone components using 3-dimensional reconstruction and modeling software. Segments were then exported into point-cloud models. Modeled defect sizes of 17 × 30 mm were created on each recipient hemicondyle. There were 2 types of donor allografts from each condyle utilized: overlapping and oblong. Grafts were virtually harvested and implanted to optimally align with the defect to provide minimal cartilage surface topography mismatch. Least mean squares distances were used to measure cartilage and subchondral surface topography mismatch and cartilage step-off. RESULTS: Cartilage and subchondral topography mismatch for the overlapping allograft group was 0.27 ± 0.02 mm and 0.80 ± 0.19 mm, respectively. In comparison, the oblong allograft group had significantly increased cartilage (0.62 ± 0.43 mm; P < .001) and subchondral (1.49 ± 1.10 mm; P < .001) mismatch. Cartilage step-off was also found to be significantly increased in the oblong group compared with the overlapping group (P < .001). In addition, overlapping allografts more reliably provided a significantly higher percentage of clinically acceptable (0.5- and 1-mm thresholds) cartilage surface topography matching (overlapping: 100% for both 0.5 and 1 mm; oblong: 90% for 1 mm and 56% for 0.5 mm; P < .001) and cartilage step-off (overlapping: 100% for both 0.5 and 1 mm; oblong: 86% for 1 mm and 12% for 0.5 mm; P < .001). CONCLUSION: This computer simulation study demonstrated improved topography matching and decreased cartilage step-off with overlapping osteochondral allografts compared with oblong osteochondral allografts when using grafts from donors that were not matched to the recipient condyle by size or radius of curvature. These findings suggest that overlapping allografts may be superior in treating large, irregular osteochondral defects involving the femoral condyles with regard to technique. CLINICAL RELEVANCE: This study suggests that overlapping allografts may provide superior articular cartilage surface topography matching compared with oblong allografts and do so in a more reliable fashion. Surgeons may consider overlapping allografts over oblong allografts because of the increased ease of topography matching during placement.


Assuntos
Cartilagem Articular , Aloenxertos , Transplante Ósseo , Cartilagem Articular/cirurgia , Simulação por Computador , Computadores , Fêmur/cirurgia , Humanos , Articulação do Joelho
17.
Mod Rheumatol ; 31(3): 614-620, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32615835

RESUMO

OBJECTIVES: We aimed to investigate patient characteristics affecting their knowledge of surgical reconstruction for rheumatoid hand and wrist deformities, and to investigate such characteristics affecting their hope of receiving hand surgery if patients with rheumatoid arthritis (RA) knew surgical reconstruction options. METHODS: We carried out a questionnaire survey for all patients with RA who came to our outpatient department of rheumatology. Multivariate logistic regression analysis was performed to examine significant characteristics associated with the knowledge of surgical reconstruction and patients' hope of receiving hand surgery. RESULTS: In total, 687 patients were evaluated in this study and 337 (49%) reported knowledge about surgical reconstruction. A multivariate logistic regression analysis showed that patients with good control of disease activity and with long-lasting hand and wrist deformities were significantly associated with having knowledge of surgical reconstruction. Among the 337 patients with knowledge, only 122 (36%) expressed a hope of receiving hand surgery. The statistical analysis showed that younger age and surgical history were significantly associated with the hope of receiving surgery. CONCLUSION: Surgeons and rheumatologists should enlighten patients about the importance of hand surgery to achieve functional remission in this new era of treatment for patients with RA.


Assuntos
Artrite Reumatoide/complicações , Deformidades Adquiridas da Mão/cirurgia , Conhecimentos, Atitudes e Prática em Saúde , Pacientes/psicologia , Procedimentos de Cirurgia Plástica/psicologia , Punho/cirurgia , Adulto , Feminino , Deformidades Adquiridas da Mão/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
18.
BMC Musculoskelet Disord ; 21(1): 732, 2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33172434

RESUMO

BACKGROUND: Fibroma of tendon sheath (FTS) is a rare benign soft tissue tumor that often occurs in the upper extremities. It manifests as a slow-growing mass, often without tenderness or spontaneous pain. FTS occurs most commonly in people aged 20-40 years and is extremely rare in young children. Because FTS presents with atypical physical and imaging findings, it might be misdiagnosed as another soft tissue tumor such as a ganglion cyst or tenosynovial giant cell tumor (TSGCT). Although marginal resection is usually performed, a high rate of local recurrence is reported. CASE PRESENTATION: A boy aged 3 years and 1 month visited our outpatient clinic with a complaint of a mass of the left hand. An elastic hard mass approximately 20 mm in diameter could be palpated on the volar side of his left little finger. This mass was initially diagnosed as a ganglion cyst at another hospital. Ultrasonography revealed a well-circumscribed hypoechoic mass with internal heterogeneity on the flexor tendon. On magnetic resonance imaging (MRI), the mass showed iso signal intensity to muscle on T1-weighted images, and homogeneously low signal intensity to muscle on T2-weighted images. The mass was peripherally enhanced after contrast administration. FTS was initially suspected as the diagnosis on the basis of these imaging features. Because of the limited range of motion of his little finger, surgery was performed when he was 4 years old. Histopathological findings indicated the mass was well-circumscribed and contained scattered spindle cells embedded in a prominent collagenous matrix. The spindle cells contained elongated and cytologically bland nuclei with a fine chromatin pattern. Nuclear pleomorphism and multinucleated giant cells were not observed. On the basis of these findings, we made a diagnosis of FTS. One year after surgery, no signs of local recurrence were observed. CONCLUSIONS: We experienced an extremely rare case of FTS in the hand of a 3-year-old child. We especially recommend ultrasonography for hand tumors of young children to diagnose or eliminate ganglion cysts. MRI helped differentially diagnose FTS from TSGCT. Although marginal resection can be performed as a treatment, great care should be taken postoperatively because FTS has a high possibility of local recurrence.


Assuntos
Fibroma , Tumor de Células Gigantes de Bainha Tendinosa , Neoplasias de Tecidos Moles , Adulto , Pré-Escolar , Humanos , Imageamento por Ressonância Magnética , Masculino , Recidiva Local de Neoplasia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/cirurgia , Tendões/diagnóstico por imagem , Tendões/cirurgia , Adulto Jovem
19.
Arthroscopy ; 36(11): 2900-2908, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32735941

RESUMO

PURPOSE: To analyze the topographic matching of oblong osteochondral allografts to treat large oval medial femoral condyle (MFC) lesions using computer simulation models. The secondary objective was to determine whether lateral femoral condyle (LFC) grafts would have a similar surface matching when compared with MFC grafts in this setting. METHODS: Human femoral hemicondyles (10 MFCs, 7 LFCs) underwent 3-dimensional computed tomography. Models were created from computed tomography images and exported into point-cloud models. Donor-recipient matches with large condylar width mismatch were excluded. The remaining specimen were divided into 3 donor-recipient groups with 2 defect sizes (17 × 30 mm and 20 × 30 mm): 20 MFC donor (MFCd)-MFC recipient (MFCr), 27 ipsilateral LFC donor (LFCd)-MFCr, and 26 contralateral LFCd-MFCr. Grafts were optimally virtually aligned with the MFCr defect. Mismatch of the articular cartilage and subchondral bone surfaces between the graft and the defect and articular step-off were calculated. RESULTS: MFCd grafts resulted in articular cartilage surface mismatch and peripheral step of less than 0.5 mm for both defect sizes. The subchondral bone surface mismatch was significantly greater than the articular cartilage surface mismatch (P < .01) in both defect sizes). Conversely, the ipsilateral and contralateral LFCd grafts resulted in significantly greater articular cartilage surface mismatch and step-off for both defect sizes when compared to MFCd grafts (P < .01). CONCLUSIONS: Oblong MFC allografts provide acceptable topographic matching for large oval MFC lesions when condylar width differences are minimized. However, concern exists in using oblong LFC allografts for MFC defects, as this can result in increased peripheral step-off and surface mismatch. CLINICAL RELEVANCE: These data reinforce the ability to use oblong MFC osteochondral allograft for treating oval cartilage lesions of the MFC when condylar width is considered. Although other studies have demonstrated LFCs can be used to treat circular defects on the MFC, this may not be true for oblong grafts.


Assuntos
Transplante Ósseo , Cartilagem Articular/patologia , Fêmur/patologia , Fêmur/cirurgia , Articulação do Joelho/patologia , Cadáver , Simulação por Computador , Epífises , Humanos , Imageamento Tridimensional , Fraturas Intra-Articulares , Tomografia Computadorizada por Raios X , Transplante Homólogo
20.
JBJS Case Connect ; 10(1): e0530, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32224650

RESUMO

CASE: A 53-year-old woman presented with Charcot arthropathy of the shoulder joint secondary to residual sensory neuropathy of Guillain-Barré syndrome, which was accompanied by swollen shoulder and restricted range of motion of the right shoulder. We performed a reverse shoulder arthroplasty (RSA). The range of motion had improved 15 months postoperatively, and there was no postoperative complication after RSA. CONCLUSION: Clinicians should be aware that Guillain-Barré syndrome can cause Charcot arthropathy of the shoulder joint. RSA is regarded as a useful treatment, although careful follow-up is needed.


Assuntos
Artroplastia do Ombro , Síndrome de Guillain-Barré/complicações , Artropatias/etiologia , Feminino , Humanos , Artropatias/diagnóstico por imagem , Artropatias/cirurgia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...