Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Odovtos (En línea) ; 23(2)ago. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386542

RESUMO

ABSTRACT: Purpose: The aim of this study is to compare the shear bond strength of three high-viscosity bulk-fill composite resins applied as single layers of 4mm thickness and of one microhybrid composite resin applied incrementally with a thickness of 2mm on dentin surfaces prepared with different surface preparation methods. Materials and Methods: A total of 132 caries-free human molars whose dentines had been exposed were used. Three groups, each containing 44 teeth, were formed. The acid group was etched with 32% phosphoric acid; laser group was etched with Er, Cr; YSGG laser and the control group was prepared with silicon carbid paper. Following the application of bonding agent, composite resin materials were applied on teeth using teflon moulds of 4x4mm. The samples were then subjected to shear bond strength tests. Two-way variance analysis and Tukey HSD multiple comparison test were applied on collected data. Results: There was a significant difference between surface treatment methods used regarding shear bond strength (P0.05). Conclusions: Laser etching of the dentin tissues is not as effective as acid etching. Bulk-fill composites had similar effects compared with conventional composite resins with regard to bonding strength. More in vitro studies supported with clinical data are required to investigate the performance of bulk-fill composites and laser.


RESUMEN: Propósito: El objetivo de este estudio es comparar la resistencia adhesiva al cizallamiento de tres resinas compuestas de relleno de alta viscosidad aplicadas como capas individuales de 4 mm de espesor y de una resina compuesta microhíbrida aplicada de forma incremental con un espesor de 2mm en superficies de dentina preparadas con diferentes métodos de preparación de la superficie. Materiales y métodos: Se utilizaron un total de 132 molares humanos sin caries cuyas dentinas habían sido expuestas. Se formaron tres grupos, cada uno con 44 dientes. El grupo ácido se grabó con ácido fosfórico al 32%; el grupo láser se grabó con Er, Cr; el láser YSGG y el grupo de control se preparó con papel de carburo de silicio. Después de la aplicación del agente adhesivo, se aplicaron materiales de resina compuesta en los dientes utilizando moldes de teflón de 4x4mm. A continuación, las muestras se sometieron a pruebas de resistencia adhesiva al cizallamiento. Se aplicó el análisis de varianza bidireccional y la prueba de comparación múltiple Tukey HSD a los datos recogidos. Resultados: Hubo una diferencia significativa entre los métodos de tratamiento de superficie utilizados en cuanto a la resistencia adhesiva al cizallamiento (P0,05). Conclusiones: El grabado láser de los tejidos de la dentina no es tan eficaz como el grabado al ácido. Las resinas de relleno bulk-fill tuvieron efectos similares en comparación con las resinas compuestas convencionales en lo que respecta a la rsistencia adhesiva. Se necesitan más estudios in vitro apoyados con datos clínicos para investigar el rendimiento de los composites de relleno y el láser.


Assuntos
Resinas Compostas/análise , Cimentos Dentários , Turquia
2.
Microsc Res Tech ; 82(11): 1878-1883, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31368622

RESUMO

The aim of this article is to compare the effects of 1.5 T and 3 T MRI on microleakage of amalgam restorations. A total of 90 extracted molar teeth were used in this study. Amalgam was used to restore standard Class V preparations (5 × 3 × 2 mm). Following the restoration, the teeth were divided into three groups according to magnetic resonance imaging (MRI) protocol (Group I: Control, Group II: 1.5 T MRI, and Group III: 3 T MRI). A total of 6,000 thermal cycles at 5°C-55°C were applied on all samples. Microleakage values were measured in millimeters using the ImageJ program. Microleakage values were higher in the gingival region compared to the occlusal region in all groups and the differences were statistically significant (p < .05). Microleakage values were not statistically different among the groups in the occlusal region (p > .05), while there were statistically significant differences among the groups with respect to microleakage values in the gingival region (p < .01). The highest mean microleakage amount in the gingival region was measured in Group III (1.192 ± 0.941 mm). This was followed by Group II (0.519 ± 0.813 mm) and Group I (0.347 ± 0.726 mm), respectively. Within the limitations of this in vitro study, we observed that higher microleakage values in amalgam restored teeth in which were exposed to MRI procedure. We also found that the teeth exposed to the stronger magnetic field showed higher microleakage amount.


Assuntos
Amálgama Dentário/efeitos da radiação , Infiltração Dentária , Campos Magnéticos/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Dente Molar/efeitos da radiação , Resinas Compostas/efeitos da radiação , Preparo da Cavidade Dentária , Restauração Dentária Permanente , Adesivos Dentinários/efeitos da radiação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...