Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
2.
ACG Case Rep J ; 5: e15, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29516016

RESUMO

Portal cavernoma colangiopathy (PCC) is an uncommon cause of portal hypertension, and it is an important differential diagnosis of pancreatic malignancy given the expanded network of collateral vessels. On imaging studies, portal cavernoma can be seen as a hypoechoic mass, possibly associated with distal common bile duct obstruction. Most cases occur in non-cirrhotic patients. During the symptomatic phase, these patients carry a high-risk of complications related to sustained biliary obstruction. We report a unique patient with obstructive jaundice and a presumed pancreatic mass that proved to be a portal cavernoma complicated by PCC in the setting of nodular regenerative hyperplasia of the liver.

3.
Endosc Int Open ; 3(5): E516-22, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26528511

RESUMO

BACKGROUND AND STUDY AIMS: Colorectal cancer can be prevented through the use of colonoscopy with polypectomy. Most colon polyps are benign or low grade adenomas. However, currently all lesions need histopathologic analysis, which increases diagnostic costs and delays the final diagnosis. Confocal laser endomicroscopy (CLE) is a new technology that enables real-time endomicroscopy. However, there are challenges to maintaining a stable image with currently available systems. We conducted a small study to obtain a preliminary assessment of whether the use of an endoscopic distal attachment cap may enhance image quality of CLE in comparison with images obtained with free-hand acquisition. PATIENTS AND METHODS: Forty outpatients underwent colonoscopy for evaluation of colon polyps in a single academic medical center. Patients were assigned randomly to 1 of 2 study arms on the basis of whether an endoscopic distal attachment cap was used (n = 21, Cap Used) or not used (n = 19, No Cap) in the procedure. The quality of confocal images and probe stabilization was summarized. RESULTS: A total of 81 polyps were identified. The proportion of polyps with images of high quality was 74 % (28/38) in the Cap Used group and 79 % (30/38) in the No Cap arm. Image stability was also similar with and without a cap. Diagnostic accuracy was estimated to be slightly higher in the Cap Used group for probe-based confocal laser endomicroscopy (pCLE; 78 % vs 70 %). This was also true for white-light and narrow-band imaging. CONCLUSIONS: This preliminary study did not yield any evidence to support that the use of an endoscopic distal attachment cap improves the quality of images obtained during CLE.

4.
Am J Gastroenterol ; 110(4): 489-96, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25267326

RESUMO

OBJECTIVES: We recently completed a randomized controlled trial of an endoscopic quality improvement program (EQUIP) that demonstrated an improved adenoma detection rate (ADR) through simple educational interventions. The aim of this study (phase III) is to examine whether the improvement in ADR in the trained endoscopists remained stable with further follow-up. METHODS: We prospectively followed up 15 staff endoscopists who had previously been randomized to a quality improvement intervention. In the current study, we examined an additional 1,200 colonoscopy procedures conducted over a 5-month time period following the original study, referred to as phase III. During this time, all physicians received quarterly ADR and other quality metric feedback, and the previous control group was offered the educational intervention voluntarily. ADRs and adenoma per patient (APP) rates were estimated in the endoscopists who were and were not randomized to EQUIP training and compared with those obtained in phases I and II of the original study. The study was conducted in a tertiary care Academic Medical Center. The study sample comprised 1200 patients undergoing routine colonoscopy. The main outcome measurement was adenoma detection rate. RESULTS: The previously observed increase in ADR in the trained group from 36% in phase I to 47% in phase II was maintained into phase III (46%). The ADR of the untrained group remained unchanged from phase I (36%) to phase II (35%); it was increased only marginally in phase III to 39%, which was still lower than the 46% ADR in the trained group. The trained group had an increase in APP, from 0.72 in Phase I to 0.87 in Phase II and 0.98 in Phase III. For the previously untrained group, there was no change in APP from phase I (0.68) to phase II (0.68), but there was possibly a small increase (to 0.74) in Phase III. CONCLUSIONS: This study provides evidence that improvements in ADR obtained through the endoscopic quality-training program can persist for at least 5 months after completion of the program. It further suggests that a focus on ADR does not lead to a "one and done" phenomenon. The limitations of this study were as follows: single-center setting, and lack of sessile polyp information/standardization.


Assuntos
Adenoma/diagnóstico , Colonoscopia/educação , Colonoscopia/normas , Neoplasias Colorretais/diagnóstico , Educação Médica Continuada/métodos , Melhoria de Qualidade , Adenoma/patologia , Adulto , Neoplasias Colorretais/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Indicadores de Qualidade em Assistência à Saúde
5.
Gastrointest Endosc ; 80(6): 1072-87, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24973171

RESUMO

BACKGROUND: Discriminating neoplastic from non-neoplastic polyps can significantly reduce the cost of colonoscopy. The American Society for Gastrointestinal Endoscopy (ASGE) recently set threshold levels for optical diagnostic accuracy to be acceptable for clinical use. OBJECTIVE: In this study, we compare a novel colonoscope capable of dual-focus imaging with standard colonoscopy with respect to the ASGE guidelines. SETTING: An academic medical center ambulatory surgical center. PATIENTS AND INTERVENTIONS: Patients at average risk were randomized to standard colonoscopy (Olympus CF-H180 and Exera II 180 colonoscopes, Olympus America, Center Valley, Pa) or dual-focus colonoscopy (Olympus CF-HQ190 and Exera III 190 colonoscopes, Olympus America). All polyps were given an optical diagnosis and compared with histology. RESULTS: A total of 600 patients were consented and 522 completed all aspects of the procedure. A total of 927 polyps were analyzed. Optical diagnostic accuracy was 79% (95% confidence interval, 74%-83%) for the 190 and 77% (95% confidence interval, 73%-81%) for the 180 colonoscope. Adenoma detection rates were also similar between the 2 groups (50% for the 190 vs 52% for the 180 colonoscope). For small distal rectosigmoid polyps with a high confidence diagnosis, the negative predictive value for adenoma was 96% (range 89%-99%) for the 180 in the narrow-band imaging (NBI) mode and 97% (range 88%-99%) for the 190 colonoscope in NBI mode. Agreement of surveillance intervals by using optical diagnosis was 94% to 95% for all modalities (180 and 190 colonoscopes, white light imaging, NBI). LIMITATIONS: Our study evaluated the accuracy of the 180 and 190 colonoscopes at a center with already-established expertise in endoscopic imaging. CONCLUSIONS: Both traditional and new dual-focus colonoscopes provide highly accurate optical polyp discrimination. There was no difference between the 2 systems in terms of discrimination or adenoma detection. Both systems are consistent with ASGE guidelines for optical diagnosis of selected colorectal polyps without histological confirmation.


Assuntos
Pólipos Adenomatosos/diagnóstico , Colo/patologia , Pólipos do Colo/diagnóstico , Colonoscópios , Neoplasias Colorretais/diagnóstico , Imagem de Banda Estreita/métodos , Reto/patologia , Pólipos Adenomatosos/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Pólipos do Colo/patologia , Colonoscopia/instrumentação , Colonoscopia/métodos , Neoplasias Colorretais/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pólipos Intestinais/diagnóstico , Pólipos Intestinais/patologia , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Valor Preditivo dos Testes
6.
Arq Gastroenterol ; 50(1): 23-30, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23657303

RESUMO

CONTEXT: Colonoscopy plays an indubitable role in the setting of clinical practice, however, it is an invasive exam; complex, lengthy, embarrassing, not devoid of risks and discomfort that yields fear and anxiety in the majority of patients. In a new era of rising competition between health institutions, where the quality of health care and client satisfaction are praised, studies regarding tolerance-related colonoscopy issues yield great potential to be explored. In the present study, tolerance is defined as willingness to repeat the exam. OBJECTIVES: Evaluate information associated to bowel preparation, the exam itself and post-examination period that might interfere with the tolerance to the colonoscopy. METHODS: Analysis of the tolerance to the colonoscopy at three stages (pre, post, and during) through a checklist: patient's questionnaire and a medical assessment form were used. RESULTS: In this present study, 91.2% of 373 patients exhibited positive tolerance to the colonoscopy. Aspects related to a negative level of tolerance were patient gender (12.9% of women versus 3.2% of men would not repeat the exam), age extremes (less than 20 years and greater than 80 years of age), and abdominal pain, both during the bowel preparation and after the procedure. CONCLUSIONS: Gender, age, patient cooperation and abdominal pain were the decisive components regarding tolerance to the colonoscopy. Notably, in two phases of the exam, the abdominal pain was the most important feature associated to a lessened tolerance.


Assuntos
Colonoscopia , Aceitação pelo Paciente de Cuidados de Saúde , Dor Abdominal/etiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Colonoscopia/efeitos adversos , Colonoscopia/psicologia , Colonoscopia/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Cuidados Pré-Operatórios/psicologia , Estudos Prospectivos , Fatores Sexuais , Inquéritos e Questionários
7.
Arq. gastroenterol ; 50(1): 23-30, Jan-Mar/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-671342

RESUMO

Context Colonoscopy plays an indubitable role in the setting of clinical practice, however, it is an invasive exam; complex, lengthy, embarrassing, not devoid of risks and discomfort that yields fear and anxiety in the majority of patients. In a new era of rising competition between health institutions, where the quality of health care and client satisfaction are praised, studies regarding tolerance-related colonoscopy issues yield great potential to be explored. In the present study, tolerance is defined as willingness to repeat the exam. Objectives Evaluate information associated to bowel preparation, the exam itself and post-examination period that might interfere with the tolerance to the colonoscopy. Methods Analysis of the tolerance to the colonoscopy at three stages (pre, post, and during) through a checklist: patient's questionnaire and a medical assessment form were used. Results In this present study, 91.2% of 373 patients exhibited positive tolerance to the colonoscopy. Aspects related to a negative level of tolerance were patient gender (12.9% of women versus 3.2% of men would not repeat the exam), age extremes (less than 20 years and greater than 80 years of age), and abdominal pain, both during the bowel preparation and after the procedure. Conclusions Gender, age, patient cooperation and abdominal pain were the decisive components regarding tolerance to the colonoscopy. Notably, in two phases of the exam, the abdominal pain was the most important feature associated to a lessened tolerance. .


Contexto É inquestionável o papel da colonoscopia na prática clínica, entretanto, trata-se de exame invasivo, complexo, demorado, impudico, não isento de riscos e desconforto, que gera receio e ansiedade à maioria dos pacientes. Em uma nova época de elevada competição entre instituições de saúde, na qual se valoriza a qualidade dos serviços prestados e satisfação dos clientes, estudos sobre fatores relacionados a tolerância à colonoscopia oferecem grande potencial a ser explorado. No presente estudo considerou-se tolerância a disposição de repetir o exame. Objetivo Analisar informações relacionados ao preparo, exame e pós exame que interferem na tolerância à colonoscopia. Métodos Análise da tolerância à colonoscopia em três momentos da colonoscopia (pré, pós e durante) através de check list: “formulário do paciente” e “ficha de avaliação médica”. Resultados No presente estudo 91.2% de 373 pacientes apresentaram tolerância positiva à colonoscopia. Os fatores relacionados à tolerância negativa foram o sexo feminino (12.9% mulheres and 3.2% dos homens não repetiriam o exame), extremos de idade (<20 anos e >80 anos) e dor abdominal durante o preparo intestinal e após o procedimento. Conclusões Gênero, idade, cooperação do paciente e dor abdominal foram fatores determinantes da tolerância à colonoscopia. Significativa em duas fases do exame, a dor abdominal foi o fator mais importante relacionado à redução da tolerância. .


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Colonoscopia , Aceitação pelo Paciente de Cuidados de Saúde , Fatores Etários , Dor Abdominal/etiologia , Colonoscopia/efeitos adversos , Colonoscopia/psicologia , Colonoscopia/estatística & dados numéricos , Estudos Prospectivos , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Cuidados Pré-Operatórios/psicologia , Fatores Sexuais , Inquéritos e Questionários
8.
Gastrointest Endosc ; 76(1): 118-25.e1, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22726470

RESUMO

BACKGROUND: Validated training methods are needed before in vivo optical diagnosis can be used to guide colorectal cancer surveillance interval assignments. OBJECTIVES: To assess the impact of endoscopist training on accuracy of surveillance intervals based on in vivo optical diagnosis. DESIGN: Prospective, randomized study. SETTING: Tertiary referral center. PATIENTS: A total of 1231 patients with colorectal polyps (before training, n = 577; after training, n = 654). INTERVENTIONS: Endoscopists were randomized to either participate or not participate in two 1-hour training sessions. Endoscopists' in vivo pathology predictions were recorded for all resected polyps. The accuracy of in vivo prediction-guided surveillance intervals were compared with pathology-guided intervals as the criterion standard. Surveillance interval accuracy before and after training were analyzed. MAIN OUTCOME MEASUREMENTS: Surveillance interval accuracy based on in vivo polyp predictions with pathology-guided intervals as criterion standard before and after a training intervention. RESULTS: Optically predicted surveillance intervals for the trained group of endoscopists had an overall accuracy of 84% (242/287) before training and 82% (261/317) after training. There was little evidence to suggest that training had a meaningful impact on the accuracy of optically predicted surveillance intervals (odds ratio 1.20; 95% CI, 0.76-1.89, P = .44). LIMITATIONS: Limitations include small sample size, lack of endoscopist prediction confidence levels, and optional use of narrow-band imaging. CONCLUSIONS: Surveillance interval accuracy did not meet published thresholds (>90%) to use in vivo optical diagnosis without pathologic confirmation. Larger studies, focused specifically on the impact of training, are needed to validate methods to improve polyp diagnosis and surveillance predication accuracy.


Assuntos
Adenoma/patologia , Pólipos do Colo/patologia , Colonoscopia/educação , Colonoscopia/normas , Neoplasias Colorretais/patologia , Vigilância da População , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalos de Confiança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Avaliação de Programas e Projetos de Saúde , Melhoria de Qualidade , Fatores de Tempo , Adulto Jovem
9.
Discov Med ; 13(71): 313-21, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22541619

RESUMO

There is intense interest in optimizing currently available colonoscopy techniques and developing new methods to improve early detection and prevention of colorectal cancer. These improvements apply to many aspects of colonoscopy, including screening effectiveness, reduced pain and complications, in vivo lesion classification, and easier insertion methods. Inherent characteristics of colonoscopy such as blind spots, residual stool, colonic contractions, and the subtle nature of some polyps present challenges to colonoscopic effectiveness. With the advent of several promising techniques, these issues are being addressed. Wide-angle colonoscopes, retroflexion, and water immersion technique are methods that have been developed. Concurrently, there is a need to reduce complications and improve patient acceptance and comfort. The education of endoscopists has appropriately focused on awareness of potential complications, with recent advances in the ability to manage complications such as bleeding and perforation. Despite its effectiveness, there are key opportunities to further improve colonoscopy including reducing the cost, improving the quality and tolerance of bowel preparation, and upgrading variance in detection and removal of polyps.


Assuntos
Colonoscopia/métodos , Pólipos do Colo/diagnóstico , Colonoscopia/tendências , Neoplasias Colorretais/diagnóstico , Humanos
10.
Am J Gastroenterol ; 107(4): 551-3, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22475963

RESUMO

An early diagnosis of colorectal polyp can be achieved through screening and surveillance programs. In the past few years, advances in endoscopic imaging of the colorectal mucosa have been extensively developed, leading to an increased detection of pre-malignant lesions as well as low-grade and nonneoplastic polyps. In order to reduce the overall cost of care with minimal impact on the quality of care in colorectal cancer prevention, the "diagnosis and discard" strategy has been considered. High-definition, narrow band imaging and confocal endomicroscopy are image enhancement technologies that have been widely studied lately. The studies from Pasha et al. and Kuiper et al. demonstrate the limitations of these new advanced imaging technologies and that further studies should continue to be developed.


Assuntos
Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Microscopia Confocal/métodos , Lesões Pré-Cancerosas/diagnóstico , Feminino , Humanos , Masculino
11.
Gastroenterol Res Pract ; 2012: 545679, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22319524

RESUMO

Confocal laser endomicroscopy (CLE) is one of several novel methods that provide real-time, high-resolution imaging at a micron scale via endoscopes. CLE has the potential to be a disruptive technology in that it can change the current algorithms that depend on biopsy to perform surveillance of high-risk conditions. Furthermore, it allows on-table decision making that has the potential to guide therapy in real time and reduce the need for repeated procedures. CLE and related technologies are often termed "virtual biopsy" as they simulate the images seen in traditional histology. However, the imaging of living tissue allows more than just pragmatic convenience; it also allows imaging of living tissue such as active capillary circulation, cellular death, and vascular and endothelial translocation, thus extending beyond what is capable in traditional biopsy. Immediate potential applications of CLE are to guide biopsy sampling in Barrett's esophagus and inflammatory bowel disease surveillance, evaluation of colorectal polyps, and intraductal imaging of the pancreas and bile duct. Data on these applications is rapidly emerging, and more is needed to clearly demonstrate the optimal applications of CLE. In this paper, we will focus on the role of CLE as applied to colorectal polyps detected during colonoscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...