Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 8(5): 568-74, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11593221

RESUMO

BACKGROUND: Technetium-labeled myocardial perfusion tracers allow the simultaneous assessment of myocardial perfusion and left ventricular function by electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT). This study evaluates left ventricular systolic and diastolic function by ECG-gated SPECT with the use of higher framing (32 frames per cardiac cycle) data acquisition. METHODS AND RESULTS: After receiving an injection of technetium 99m tetrofosmin, 48 patients with cardiac diseases were examined by ECG-gated myocardial perfusion SPECT with a 3-headed gamma camera. During gated data collection, 32 frames per cardiac cycle were acquired over 360 degrees in 60 steps, each of which consisted of 60 beats. Immediately thereafter, the 32 frames taken at each projection angle were combined into 16-frame and 8-frame data sets. Left ventricular end-diastolic volume (LVEDV, in milliliters), left ventricular end-systolic volume (LVESV, in milliliters), and left ventricular ejection fraction (LVEF, percentage) were automatically calculated from the 32-frame, 16-frame, and 8-frame gated data sets. Left ventricular time-volume curves from the 3 data sets were generated by Fourier curve fitting analysis with the use of 3 harmonics, and then peak filling rate (PFR, per second) was measured. Twenty-nine patients also underwent multigated equilibrium radionuclide angiography (ERNA) to determine the LVEF and PFR. Combining the 32-frame data into 16-frame and 8-frame data sets from the 48 patients generated a smaller LVEDV and a larger LVESV, and LVEF was significantly lower in accordance with the decreasing number of frames. Compared with ERNA studies (n = 29), the Bland-Altman method showed underestimated LVEFs and larger 95% limits of agreement in lower framing gated SPECT. CONCLUSIONS: Left ventricular functional parameters obtained from 32-frame gated SPECT correlated closely with those determined by ERNA studies. ECG-gated SPECT with 32-frame data can provide comprehensive information with which to evaluate many types of cardiac diseases.


Assuntos
Circulação Coronária , Diástole , Imagem do Acúmulo Cardíaco de Comporta , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Kaku Igaku ; 38(3): 249-54, 2001 May.
Artigo em Japonês | MEDLINE | ID: mdl-11452492

RESUMO

Multigated equilibrium radionuclide ventriculography from best septal position (LAO view) was performed in 17 patients with cardiac disease with a single detector Anger-type gamma camera (GCA 602A, Toshiba), then immediately imaged with a solid-state, multi-crystal gamma camera (Digirad 2020tc Imager). Acquisition times were the same of 10 minutes. The solid-state gamma camera uses CsI(Tl) as the scintillation material and a Si photodiode. CsI(Tl) has a higher density and higher atomic number than NaI(Tl), so that its efficiency for detecting gamma rays is higher. To confirm this, total acquisition counts in 17 patients obtained from the 2020tc Imager were significantly higher than those obtained from the Anger-type camera (7847 +/- 2061 K vs. 4427 +/- 1162 K counts, p < 0.0001). In comparing left ventricular ejection fractions obtained from the Anger-type camera and the 2020tc Imager data, an excellent correlation was revealed with a correlation coefficient of 0.97 (p < 0.0001). Again, peak ejection rate and peak filling rate obtained from the 2020tc Imager data correlated well with those obtained from the Anger-type camera data (r = 0.93, p < 0.0001 and r = 0.80, p < 0.001, respectively). These data reveal that the 2020tc Imager has an excellent data collection efficiency and a high reliability in assessment of left ventricular function. Thus, the solid-state gamma camera was thought to be a useful hardware in nuclear cardiology.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m , Função Ventricular Esquerda , Idoso , Angina Pectoris/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Feminino , Câmaras gama , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...