Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Intensive Care Med ; 48(8): 1009-1023, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35723686

RESUMO

PURPOSE: Severe community-acquired pneumonia (CAP) requiring intensive care unit admission is associated with significant acute and long-term morbidity and mortality. We hypothesized that downregulation of systemic and pulmonary inflammation with prolonged low-dose methylprednisolone treatment would accelerate pneumonia resolution and improve clinical outcomes. METHODS: This double-blind, randomized, placebo-controlled clinical trial recruited adult patients within 72-96 h of hospital presentation. Patients were randomized in 1:1 ratio; an intravenous 40 mg loading bolus was followed by 40 mg/day through day 7 and progressive tapering during the 20-day treatment course. Randomization was stratified by site and need for mechanical ventilation (MV) at the time of randomization. Outcomes included a primary endpoint of 60-day all-cause mortality and secondary endpoints of morbidity and mortality up to 1 year of follow-up. RESULTS: Between January 2012 and April 2016, 586 patients from 42 Veterans Affairs Medical Centers were randomized, short of the 1420 target sample size because of low recruitment. 584 patients were included in the analysis. There was no significant difference in 60-day mortality between the methylprednisolone and placebo arms (16% vs. 18%; adjusted odds ratio 0.90, 95% CI 0.57-1.40). There were no significant differences in secondary outcomes or complications. CONCLUSIONS: In patients with severe CAP, prolonged low-dose methylprednisolone treatment did not significantly reduce 60-day mortality. Treatment was not associated with increased complications.


Assuntos
Infecções Comunitárias Adquiridas , Pneumonia , Adulto , Infecções Comunitárias Adquiridas/tratamento farmacológico , Estado Terminal/terapia , Humanos , Metilprednisolona/uso terapêutico , Pneumonia/tratamento farmacológico , Respiração Artificial , Resultado do Tratamento
2.
Am J Cardiol ; 162: 24-30, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34736721

RESUMO

Saphenous vein grafts (SVGs) have high rates of in-stent restenosis (ISR). We compared the baseline clinical and angiographic characteristics of patients and lesions that did develop ISR with those who did not develop ISR during a median follow-up of 2.7 years in the DIVA study (NCT01121224). We also examined the ISR types using the Mehran classification. ISR developed in 119 out of the 575 DIVA patients (21%), with similar incidence among patients with drug-eluting stents and bare-metal stents (BMS) (21% vs 21%, p = 0.957). Patients in the ISR group were younger (67 ± 7 vs 69 ± 8 years, p = 0.04) and less likely to have heart failure (27% vs 38%, p = 0.03) and SVG lesions with Thrombolysis In Myocardial Infarction 3 flow before the intervention (77% vs 83%, p <0.01), but had a higher number of target SVG lesions (1.33 ± 0.64 vs 1.16 ± 0.42, p <0.01), more stents implanted in the target SVG lesions (1.52 ± 0.80 vs 1.31 ± 0.66, p <0.01), and longer total stent length (31.37 ± 22.11 vs 25.64 ± 17.42 mm, p = 0.01). The incidence of diffuse ISR was similar in patients who received drug-eluting-stents and BMS (57% vs 54%, p = 0.94), but BMS patients were more likely to develop occlusive restenosis (17% vs 33%, p = 0.05).


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/epidemiologia , Stents Farmacológicos/efeitos adversos , Oclusão de Enxerto Vascular/epidemiologia , Veia Safena/transplante , Fatores Etários , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco
4.
Circ Cardiovasc Interv ; 13(2): e008494, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32019343

RESUMO

BACKGROUND: Direct stenting without pre-dilation or post-dilation has been advocated for saphenous vein graft percutaneous coronary intervention to decrease the incidence of distal embolization, periprocedural myocardial infarction, and target lesion revascularization. METHODS: We performed a post hoc analysis of patients enrolled in the DIVA (Drug-Eluting Stents Versus Bare Metal Stents in Saphenous Vein Graft Angioplasty; NCT01121224) prospective, double-blind, randomized controlled trial. Patients were stratified into stent-only and balloon-stent groups. Primary end point was 12-month incidence of target vessel failure (defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization). Secondary end points included all-cause death, stent thrombosis, myocardial infarction, and target lesion revascularization during follow-up. RESULTS: Of the 575 patients included in this substudy, 185 (32%) patients underwent stent-only percutaneous coronary intervention. Patients in the stent-only versus balloon-stent group had similar baseline characteristics and similar incidence of target vessel failure at 12-months (15% versus 19%; hazard ratio, 1.34 [95% CI, 0.86-2.08]; P=0.19). During long-term follow-up (median of 2.7 years), the incidence of definite stent thrombosis (1% versus 5%; hazard ratio, 9.20 [95% CI, 1.23-68.92]; P=0.0085), the composite of definite or probable stent thrombosis (5% versus 11%; hazard ratio, 2.52 [95% CI, 1.23-5.18]; P=0.009), and target vessel myocardial infarction (8% versus 14%; hazard ratio, 1.92 [95% CI, 1.08-3.40]; P=0.023) was lower in the stent-only group. Multivariable analysis showed that a higher number of years since coronary artery bypass grafting and >1 target saphenous vein graft lesions were associated with increased target vessel failure during entire follow-up, while preintervention Thrombolysis in Myocardial Infarction-3 flow was protective. CONCLUSIONS: In patients undergoing percutaneous coronary intervention of de novo saphenous vein graft lesions, there was no difference in target vessel failure at 12 months and long-term follow-up in the stent-only versus the balloon-stent group; however, the incidence of stent thrombosis was lower in the stent-only group, as was target vessel myocardial infarction. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01121224.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia/instrumentação , Ponte de Artéria Coronária/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Veia Safena/transplante , Stents , Idoso , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Ponte de Artéria Coronária/mortalidade , Trombose Coronária/etiologia , Método Duplo-Cego , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/mortalidade , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Fatores de Risco , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
5.
Lancet ; 391(10134): 1997-2007, 2018 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-29759512

RESUMO

BACKGROUND: Few studies have examined the efficacy of drug-eluting stents (DES) for reducing aortocoronary saphenous vein bypass graft (SVG) failure compared with bare-metal stents (BMS) in patients undergoing stenting of de-novo SVG lesions. We assessed the risks and benefits of the use of DES versus BMS in de-novo SVG lesions. METHODS: Patients were recruited to our double-blind, randomised controlled trial from 25 US Department of Veterans Affairs centres. Eligible participants were aged at least 18 years and had at least one significant de-novo SVG lesion (50-99% stenosis of a 2·25-4·5 mm diameter SVG) requiring percutaneous coronary intervention with intent to use embolic protection devices. Enrolled patients were randomly assigned, in a 1:1 ratio, by phone randomisation system to receive a DES or BMS. Randomisation was stratified by presence or absence of diabetes and number of target SVG lesions requiring percutaneous coronary intervention (one or two or more) within each participating site by use of an adaptive scheme intended to balance the two stent type groups on marginal totals for the stratification factors. Patients, referring physicians, study coordinators, and outcome assessors were masked to group allocation. The primary endpoint was the 12-month incidence of target vessel failure, defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularisation. The DIVA trial is registered with ClinicalTrials.gov, number NCT01121224. FINDINGS: Between Jan 1, 2012, and Dec 31, 2015, 599 patients were randomly assigned to the stent groups, and the data for 597 patients were used. The patients' mean age was 68·6 (SD 7·6) years, and 595 (>99%) patients were men. The two stent groups were similar for most baseline characteristics. At 12 months, the incidence of target vessel failure was 17% (51 of 292) in the DES group versus 19% (58 of 305) in the BMS group (adjusted hazard ratio 0·92, 95% CI 0·63-1·34, p=0·70). Between-group differences in the components of the primary endpoint, serious adverse events, or stent thrombosis were not significant. Enrolment was stopped before the revised target sample size of 762 patients was reached. INTERPRETATION: In patients undergoing stenting of de-novo SVG lesions, no significant differences in outcomes between those receiving DES and BMS during 12 months of follow-up were found. The study results have important economic implications in countries with high DES prices such as the USA, because they suggest that the lower-cost BMS can be used in SVG lesions without compromising either safety or efficacy. FUNDING: US Department of Veterans Affairs Cooperative Studies Program.


Assuntos
Rejeição de Enxerto/tratamento farmacológico , Intervenção Coronária Percutânea/instrumentação , Veia Safena/cirurgia , Trombose/epidemiologia , Idoso , Método Duplo-Cego , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents Metálicos Autoexpansíveis , Trombose/etiologia , Resultado do Tratamento
6.
J Gen Intern Med ; 31(9): 1061-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27234663

RESUMO

BACKGROUND: Effective management of patients using warfarin is resource-intensive, requiring frequent in-clinic testing of the international normalized ratio (INR). Patient self-testing (PST) using portable at-home INR monitoring devices has emerged as a convenient alternative. As revealed by The Home INR Study (THINRS), event rates for PST were not significantly different from those for in-clinic high-quality anticoagulation management (HQACM), and a cumulative gain in quality of life was observed for patients undergoing PST. OBJECTIVE: To perform a cost-utility analysis of weekly PST versus monthly HQACM and to examine the sensitivity of these results to testing frequency. PATIENTS/INTERVENTIONS: In this study, 2922 patients taking warfarin for atrial fibrillation or mechanical heart valve, and who demonstrated PST competence, were randomized to either weekly PST (n = 1465) or monthly in-clinic testing (n = 1457). In a sub-study, 234 additional patients were randomized to PST once every 4 weeks (n = 116) or PST twice weekly (n = 118). The endpoints were quality of life (measured by the Health Utilities Index), health care utilization, and costs over 2 years of follow-up. RESULTS: PST and HQACM participants were similar with regard to gender, age, and CHADS2 score. The total cost per patient over 2 years of follow-up was $32,484 for HQACM and $33,460 for weekly PST, representing a difference of $976. The incremental cost per quality-adjusted life year gained with PST once weekly was $5566 (95 % CI, -$11,490 to $25,142). The incremental cost-effectiveness ratio (ICER) was sensitive to testing frequency: weekly PST dominated PST twice weekly and once every 4 weeks. Compared to HQACM, weekly PST was associated with statistically significant and clinically meaningful improvements in quality of life. The ICER for weekly PST versus HQACM was well within accepted standards for cost-effectiveness, and was preferred over more or less frequent PST. These results were robust to sensitivity analyses of key assumptions. CONCLUSION: Weekly PST is a cost-effective alternative to monthly HQACM and a preferred testing frequency compared to twice weekly or monthly PST.


Assuntos
Instituições de Assistência Ambulatorial/economia , Análise Custo-Benefício/métodos , Monitoramento de Medicamentos/economia , Serviços de Assistência Domiciliar/economia , Coeficiente Internacional Normatizado/economia , Autocuidado/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Instituições de Assistência Ambulatorial/normas , Anticoagulantes/economia , Anticoagulantes/uso terapêutico , Análise Custo-Benefício/normas , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/normas , Feminino , Seguimentos , Serviços de Assistência Domiciliar/normas , Hospitais de Veteranos/economia , Hospitais de Veteranos/normas , Humanos , Coeficiente Internacional Normatizado/métodos , Coeficiente Internacional Normatizado/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Autocuidado/métodos , Autocuidado/normas , Varfarina/economia , Varfarina/uso terapêutico , Adulto Jovem
7.
Am J Manag Care ; 22(1): 65-71, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26799126

RESUMO

OBJECTIVES: Patient self-testing (PST) improves anticoagulation control and patient satisfaction. It is unknown whether these effects are more pronounced when the patient lives farther from the anticoagulation clinic (ACC). If the benefits of PST are limited to a subset of patients (those living farther from care), selectively providing PST to that subset could enhance cost-effectiveness. STUDY DESIGN: This is a secondary analysis of a randomized trial of PST versus usual ACC care, which involved 2922 patients of the Veterans Health Administration (VHA). METHODS: Our 3 outcomes were the primary composite clinical end point (stroke, major hemorrhage, or death), anticoagulation control (percent time in therapeutic range), and satisfaction with anticoagulation care. We measured the driving distance between the patient's residence and the nearest VHA facility. We divided patients into quartiles by distance and looked for evidence of an interaction between distance and the effect of the intervention on the 3 outcomes. RESULTS: The median driving distance was 12 miles (interquartile range = 6-21). Patients living in the farthest quartile had higher rates of the primary composite clinical end point in both groups compared with patients living in the nearest quartile. For PST, the hazard ratio (HR) was 1.77 (95% CI, 1.18-2.64), and for usual care, the HR was 1.81 (95% CI, 1.19-2.75). Interaction terms did not suggest that distance to care modified the effect of the intervention on any outcome. CONCLUSIONS: The benefits of PST were not enhanced among patients living farther from care. Restricting PST to patients living more than a certain distance from the ACC is not likely to improve its cost-effectiveness.


Assuntos
Anticoagulantes/administração & dosagem , Monitoramento de Medicamentos , Sistemas Automatizados de Assistência Junto ao Leito , Autocuidado , Viagem/estatística & dados numéricos , Administração Oral , Idoso , Feminino , Acessibilidade aos Serviços de Saúde , Humanos , Coeficiente Internacional Normatizado , Masculino , Adesão à Medicação , Satisfação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto , Estados Unidos , Veteranos
8.
J Thromb Thrombolysis ; 40(1): 17-25, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25209313

RESUMO

Anticoagulation (AC) is effective in reducing thromboembolic events for individuals with atrial fibrillation (AF) or mechanical heart valve (MHV), but maintaining patients in target range for international normalized ratio (INR) can be difficult. Evidence suggests increasing INR testing frequency can improve time in target range (TTR), but this can be impractical with in-clinic testing. The objective of this study was to test the hypothesis that more frequent patient-self testing (PST) via home monitoring increases TTR. This planned substudy was conducted as part of The Home INR Study, a randomized controlled trial of in-clinic INR testing every 4 weeks versus PST at three different intervals. The setting for this study was 6 VA centers across the United States. 1,029 candidates with AF or MHV were trained and tested for competency using ProTime INR meters; 787 patients were deemed competent and, after second consent, randomized across four arms: high quality AC management (HQACM) in a dedicated clinic, with venous INR testing once every 4 weeks; and telephone monitored PST once every 4 weeks; weekly; and twice weekly. The primary endpoint was TTR at 1-year follow-up. The secondary endpoints were: major bleed, stroke and death, and quality of life. Results showed that TTR increased as testing frequency increased (59.9 ± 16.7 %, 63.3 ± 14.3 %, and 66.8 ± 13.2 % [mean ± SD] for the groups that underwent PST every 4 weeks, weekly and twice weekly, respectively). The proportion of poorly managed patients (i.e., TTR <50 %) was significantly lower for groups that underwent PST versus HQACM, and the proportion decreased as testing frequency increased. Patients and their care providers were unblinded given the nature of PST and HQACM. In conclusion, more frequent PST improved TTR and reduced the proportion of poorly managed patients.


Assuntos
Serviços de Assistência Domiciliar/normas , Coeficiente Internacional Normatizado/normas , Tempo de Protrombina/normas , Autocuidado/normas , United States Department of Veterans Affairs/normas , Idoso , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/normas , Feminino , Seguimentos , Humanos , Coeficiente Internacional Normatizado/métodos , Masculino , Pessoa de Meia-Idade , Tempo de Protrombina/métodos , Autocuidado/métodos , Fatores de Tempo , Estados Unidos
9.
N Engl J Med ; 363(17): 1608-20, 2010 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-20961244

RESUMO

BACKGROUND: Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. METHODS: We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). RESULTS: The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). CONCLUSIONS: As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).


Assuntos
Anticoagulantes/uso terapêutico , Monitoramento de Medicamentos/métodos , Coeficiente Internacional Normatizado , Autocuidado , Varfarina/uso terapêutico , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Hemorragia/epidemiologia , Hemorragia/prevenção & controle , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/epidemiologia , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/prevenção & controle , Varfarina/efeitos adversos
10.
J Thromb Thrombolysis ; 30(3): 263-75, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20628787

RESUMO

Prior studies suggest patient self-testing (PST) of prothrombin time (PT) can improve the quality of anticoagulation (AC) and reduce complications (e.g., bleeding and thromboembolic events). "The Home INR Study" (THINRS) compared AC management with frequent PST using a home monitoring device to high-quality AC management (HQACM) with clinic-based monitoring on major health outcomes. A key clinical and policy question is whether and which patients can successfully use such devices. We report the results of Part 1 of THINRS in which patients and caregivers were evaluated for their ability to perform PST. Study-eligible patients (n = 3643) were trained to use the home monitoring device and evaluated after 2-4 weeks for PST competency. Information about demographics, medical history, warfarin use, medications, plus measures of numeracy, literacy, cognition, dexterity, and satisfaction with AC were collected. Approximately 80% (2931 of 3643) of patients trained on PST demonstrated competency; of these, 8% (238) required caregiver assistance. Testers who were not competent to perform PST had higher numbers of practice attempts, higher cuvette wastage, and were less able to perform a fingerstick or obtain blood for the cuvette in a timely fashion. Factors associated with failure to pass PST training included increased age, previous stroke history, poor cognition, and poor manual dexterity. A majority of patients were able to perform PST. Successful home monitoring of PT with a PST device required adequate levels of cognition and manual dexterity. Training a caregiver modestly increased the proportion of patients who can perform PST.


Assuntos
Monitoramento de Medicamentos/métodos , Seleção de Pacientes , Tempo de Protrombina/métodos , Autocuidado/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Fibrilação Atrial , Custos e Análise de Custo , Monitoramento de Medicamentos/normas , Feminino , Próteses Valvulares Cardíacas , Hemorragia , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Tempo de Protrombina/instrumentação , Curva ROC , Autocuidado/métodos , Varfarina/uso terapêutico , Adulto Jovem
11.
J Card Fail ; 13(6): 437-44, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17675057

RESUMO

BACKGROUND: Serial neurohormones may serve as markers of efficacy of congestive heart failure (CHF) therapy. We measured serial plasma big-endothelin (Big-ET), ET-1, N-terminal atrial natriuretic peptide, and brain natriuretic peptide (BNP) in 206 patients randomized to bucindolol or placebo in Beta-Blocker Evaluation of Survival Trial (BEST). METHODS AND RESULTS: Neurohormones were measured at baseline and 3 and 12 months. At baseline, BNP and Big-ET levels were greater in New York Heart Association (NYHA) Class IV than in Class III patients (median 122 pg/mL versus 447 pg/mL, P = .001; and 20.0 pg/mL versus 9.9 pg/mL, P = .003), and in patients with left ventricular ejection fraction (LVEF) < or = 20% compared with LVEF > 20% (median 211 pg/mL versus 99.1 pg/mL; and 12.9 pg/mL versus 8.0 pg/mL, both P = .003). Big-ET and BNP were the strongest predictors of the composite end point of CHF hospitalization or death. LVEF at 12 months correlated inversely with 12-month BNP levels (r = -0.41, P = .0001). Bucindolol had no effect on neurohormones except that bucindolol treated patients had lower Big-ET levels at 3 months than patients receiving placebo (median 9.1 pg/mL versus 10.9 pg/mL, P = .05). A decline in ET-1 was associated with increased risk of the composite endpoint. CONCLUSIONS: Lack of effect of bucindolol on natriuretic peptide levels appears consistent with its overall lack of efficacy in BEST.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Fator Natriurético Atrial/sangue , Endotelina-1/sangue , Endotelinas/sangue , Insuficiência Cardíaca/tratamento farmacológico , Peptídeo Natriurético Encefálico/sangue , Propanolaminas/uso terapêutico , Idoso , Biomarcadores/sangue , Feminino , Seguimentos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Radioimunoensaio , Volume Sistólico , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...