Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cytometry B Clin Cytom ; 70(4): 270-5, 2006 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16906585

RESUMO

Lack of immunoglobulin heavy chain genes (IgV(H)) mutation in patients with chronic lymphocytic leukemia (CLL) is associated with rapid disease progression and shorter survival. The zeta-chain (T-cell receptor) associated protein kinase 70 kDa (ZAP-70) has been reported to be a surrogate marker for IgV(H) mutation status, and its expression in leukemic cells correlates with unmutated IgV(H). However, ZAP-70 detection by flow cytometry varies significantly dependant on the antibodies used, the method of performing the assay, and the condition of the cells in the specimen. The clinical value of ZAP-70 testing when samples are shipped under poorly controlled conditions is not known. Furthermore, testing in a research environment may differ from testing in a routine clinical laboratory. We validated an assay for ZAP-70 by comparing results with clinical outcome and the mutation status of the IgV(H). Using stored samples, we show significant correlation between ZAP-70 expression and clinical outcome as well as IgV(H) mutation at a cut-off point of 15%. While positive samples (>15% positivity) remain positive when kept in the laboratory environment for 48 h after initial testing, results obtained from samples from CLL patients tested after shipping at room temperature for routine testing showed no correlation with IgV(H) mutation status when 15% cut-off was used. In these samples, cut-point of 10% correlated with the IgV(H) mutation (P = 0.0001). This data suggests that although ZAP-70 positivity correlates with IgV(H) mutation status and survival, variations in sample handling and preparation may influence results. We show that IgV(H) mutation results, unlike ZAP-70 remain correlated with CD38 expression and beta-2 microglobulin in shipped samples, and ZAP-70 testing should not be used as the sole criterion for stratifying patients for therapy.


Assuntos
Citometria de Fluxo/métodos , Cadeias Pesadas de Imunoglobulinas/genética , Região Variável de Imunoglobulina/genética , Leucemia Linfocítica Crônica de Células B/diagnóstico , Proteína-Tirosina Quinase ZAP-70/análise , ADP-Ribosil Ciclase 1/análise , ADP-Ribosil Ciclase 1/biossíntese , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/biossíntese , Feminino , Humanos , Estimativa de Kaplan-Meier , Leucemia Linfocítica Crônica de Células B/genética , Masculino , Mutação , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Manejo de Espécimes , Coloração e Rotulagem , Taxa de Sobrevida , Proteína-Tirosina Quinase ZAP-70/biossíntese , Microglobulina beta-2/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...